Introduction: Immune checkpoint inhibitors (ICI) are now a standard of care in the treatment of many cancers leading to durable responses in patients with metastatic disease. These agents are generally well tolerated but may lead to the occurrence of immune-related adverse events (irAEs). As any organ may be affected, clinicians should be aware of the broad range of clinical manifestations and symptoms and keep in mind that toxicities may occur late, at any point along a patient’s treatment course. Although the most common irAEs are rarely severe, some of them may be associated with great morbidity and even become life-threatening. The rate of occurrence, type and severity of irAEs may vary with the type of ICI; thus, grade 3 and 4 irAEs are reported in more than 55% of patients treated with the combination of ipilimumab 3 mg/kg and nivolumab 1 mg/kg.
Area covered: This review presents the management of irAEs resulting from checkpoint blockade, with a focus on rare irAEs.
Expert commentary: With the development of immuno-oncology and the expanding role of ICI, physicians have learnt to diagnose and treat most of the irAEs that can occur. This review provides an overview of current guidelines, previously published studies and our multidisciplinary team based practices. 相似文献
Introduction: Collaborative interactions between several diverse biological processes govern the onset and progression of breast cancer. These processes include alterations in cellular metabolism, anti-tumor immune responses, DNA damage repair, proliferation, anti-apoptotic signals, autophagy, epithelial-mesenchymal transition, components of the non-coding genome or onco-mIRs, cancer stem cells and cellular invasiveness. The last two decades have revealed that each of these processes are also directly regulated by a component of the cell cycle apparatus, cyclin D1.
Area covered: The current review is provided to update recent developments in the clinical application of cyclin/CDK inhibitors to breast cancer with a focus on the anti-tumor immune response.
Expert opinion: The cyclin D1 gene encodes the regulatory subunit of a proline-directed serine-threonine kinase that phosphorylates several substrates. CDKs possess phosphorylation site selectivity, with the phosphate-acceptor residue preceding a proline. Several important proteins are substrates including all three retinoblastoma proteins, NRF1, GCN5, and FOXM1. Over 280 cyclin D3/CDK6 substrates have b\een identified. Given the diversity of substrates for cyclin/CDKs, and the altered thresholds for substrate phosphorylation that occurs during the cell cycle, it is exciting that small molecular inhibitors targeting cyclin D/CDK activity have encouraging results in specific tumors. 相似文献
Magnetic field generated by neuronal activity could alter magnetic resonance imaging (MRI) signals but detection of such signal is under debate. Previous researches proposed that magnitude signal change is below current detectable level, but phase signal change (PSC) may be measurable with current MRI systems. Optimal imaging parameters like echo time, voxel size and external field direction, could increase the probability of detection of this small signal change. We simulate a voxel of cortical column to determine effect of such parameters on PSC signal. We extended a laminar network model for somatosensory cortex to find neuronal current in each segment of pyramidal neurons (PN). 60,000 PNs of simulated network were positioned randomly in a voxel. Biot–savart law applied to calculate neuronal magnetic field and additional phase. The procedure repeated for eleven neuronal arrangements in the voxel. PSC signal variation with the echo time and voxel size was assessed. The simulated results show that PSC signal increases with echo time, especially 100/80 ms after stimulus for gradient echo/spin echo sequence. It can be up to 0.1 mrad for echo time = 175 ms and voxel size = 1.48 × 1.48 × 2.18 mm3. With echo time less than 25 ms after stimulus, it was just acquired effects of physiological noise on PSC signal. The absolute value of the signal increased with decrease of voxel size, but its components had complex variation. External field orthogonal to local surface of cortex maximizes the signal. Expected PSC signal for tactile detection in the somatosensory cortex increase with echo time and have no oscillation. 相似文献
In the current immunosuppressive therapy era, vessel thrombosis is the most common cause of early graft loss after renal transplantation. The prevalence of IgA anti–β2-glycoprotein I antibodies (IgA-aB2GPI-ab) in patients on dialysis is elevated (>30%), and these antibodies correlate with mortality and cardiovascular morbidity. To evaluate the effect of IgA-aB2GPI-ab in patients with transplants, we followed all patients transplanted from 2000 to 2002 in the Hospital 12 de Octubre prospectively for 10 years. Presence of IgA-aB2GPI-ab in pretransplant serum was examined retrospectively. Of 269 patients, 89 patients were positive for IgA-aB2GPI-ab (33%; group 1), and the remaining patients were negative (67%; group 2). Graft loss at 6 months post-transplant was significantly higher in group 1 (10 of 89 versus 3 of 180 patients in group 2; P=0.002). The most frequent cause of graft loss was thrombosis of the vessels, which was observed only in group 1 (8 of 10 versus 0 of 3 patients in group 2; P=0.04). Multivariate analysis showed that the presence of IgA-aB2GPI-ab was an independent risk factor for early graft loss (P=0.04) and delayed graft function (P=0.04). There were no significant differences regarding patient survival between the two groups. Graft survival was similar in both groups after 6 months. In conclusion, patients with pretransplant IgA-aB2GPI-ab have a high risk of early graft loss caused by thrombosis and a high risk of delayed graft function. Therefore, pretransplant IgA-aB2GPI-ab may have a detrimental effect on early clinical outcomes after renal transplantation. 相似文献
AbstractSupporting patients in making informed healthcare decisions is a cornerstone of ethical medical practice. Surgeons frequently draw for and show images to patients when consenting them for operations but the value of this practice in informed decision-making is unclear. An audit was conducted in a General Surgery Department. 244 patients completed questionnaires on the value of visual materials when giving consent for surgery. The complexity of the operations was classified into “simple”, “moderate” or “complex”. 100% of patients felt they had given informed consent to surgery. 62% of patients received at least one form of visual material during the consenting process. All patients who received a drawing, and 99% of those provided with other images, valued these resources. Visual materials were considered more useful to patients when giving consent for moderate or complex operations than simple ones. Approximately one third of patients who did not receive visual materials would have appreciated these when making an informed decision. This research highlights the value of surgeons drawing for, and providing other visual resources to, their patients as part of the consent process. There is a role for further research and training materials in drawing skills for surgeons. 相似文献
Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices.With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored.With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres.Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected.Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5.MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink. 相似文献