首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   2篇
  免费   0篇
临床医学   2篇
  2007年   1篇
  1990年   1篇
排序方式: 共有2条查询结果,搜索用时 0 毫秒
1
1.
BONGIORNI, M.G., ET AL.: Evaluation of Rate-Responsive Pacemakers by Transesophageal Holter Monitoring of Spontaneous Atrial Rate. One of the most important problems in rate responsive (RR) pacing is the clinical experimental evaluation of the reliability of various sensors. In particular, it is difficult to test their sensitivity and specificity during daily activity of the patients. Atrial rate, when present and normal, is the most physiological marker of metabolic requirements, but sometimes it is impossible to analyze the P wave in ventricular paced rhythm during routinely performed tests (e.g., ergometric test and 24-hour Holter monitoring). During various physical activities, we monitored atrial electrograms on an esophageal lead on the first channel of a standard Holter tape recorder; on the second channel a surface ECG lead was recorded. We selected 10 patients with high grade heart block and normal sinus node function paced in RR-VVI mode. RR pacing was obtained using various sensors (body activity, blood temperature, spike-T interval, minute ventilation). The good quality of recording allowed an easy evaluation of atrial and ventricular rates. In four cases an appropriate increase in heart rate was documented; sensitivity threshold and/or rate response slope were reprogrammed when indicated. The pacing rate of one patient did not parallel the atrial rate during walking only. In three cases, we observed a delay in the ventricular rate increase, with ventricular rate decreasing at peak exercise despite further atrial rate increase. In the last two patients, we observed inappropriate pacing response; pacing rate increased later and to a lower level than the atrial one. This new method is applied easily and appears reliable to evaluate the response of RR pacemakers to individual metabolic needs. Its applicability is, however, limited by the need for a normal sinus node function. In conclusion, transesophageal atrial rate recording is a useful tool for the clinical evaluation of RR pacemakers, and it can be proposed as a new method for testing new sensors.  相似文献   
2.
While the beneficial effects of cardiac resynchronization therapy (CRT) on left ventricular (LV) systolic function have been demonstrated, no information is available regarding its effects on LV diastolic function during exercise. Using radionuclide angiography, we prospectively evaluated the effects of CRT on diastolic function at rest and during exercise in 15 patients consecutively referred for CRT. All patients underwent equilibrium Tc99 radionuclide angiography with bicycle exercise performed (1) at baseline; (2) immediately after CRT implantation, in spontaneous rhythm and during CRT; and (3) after 3 months of biventricular stimulation. Diastolic function was assessed by measurements of peak filling rate (PFR). At baseline, activation of biventricular stimulation influenced PFR neither at rest (1.06 ± 0.34 vs 1.07 ± 0.50 mL/s during spontaneous rhythm, P = 0.9) nor during exercise (1.45 ± 0.62 vs 1.33 ± 0.48 mL/s, P = 0.3). At 3 months, improvements were observed in New York Heart Association functional class and systolic function. By contrast, no improvement in diastolic function was observed either at rest (PFR = 1.11 ± 0.45 vs 1.07 ± 0.50 mL/s in spontaneous rhythm at baseline, P = 0.6) or during exercise (1.23 ± 0.50 vs 1.33 ± 0.48 mL/s, P = 0.2). These observations indicate that the intermediate benefits conferred by CRT on LV systolic function at rest and during exercise were not accompanied by similar improvements in diastolic function .  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号