Objective: To compare the rates of all-cause mortality in recipients of cardiac resynchronization therapy devices without (CRT-PM) versus with defibrillator (CRT-D).
Methods: Between February 1999 and July 2004, 233 patients (mean age = 69 ± 8 years, 180 men) underwent implantation of CRT-PM or CRT-D devices. New York Heart Association (NYHA) heart failure functional class II was present in 11%, class III in 69%, and class IV in 20% of patients; mean left ventricle ejection fraction (LVEF) was 26.5 ± 6.5 %, 48% presented with idiopathic dilated cardiomyopathy and 49% with ischemic heart disease. Cox multiple variable regression analysis was performed in search of predictors of death.
Results: The clinical characteristics of the 117 CRT-PM and 116 CRT-D recipients were similar, except for LVEF (28.2 ± 6.2% vs 25.0 ± 6.5%, respectively; P < 0.001), and ischemic versus nonischemic etiology of heart failure (41% vs 56%, respectively P = 0.02). Over a mean follow-up of 58 ± 15 months, no significance difference in overall mortality rate was observed between the two study groups. Male sex, NYHA functional class IV, and atrial fibrillation at implant were significant predictors of death.
Conclusions: There was no difference in long-term survival rate among patients with CRT-D versus CRT-PM, although CRT-D more effectively lowered the sudden death rate. Male sex, NYHA functional class IV, and atrial fibrillation predicted the worst prognosis.  相似文献   
2.
Persistent Electrical Isolation of Pulmonary Veins . Introduction: Aim of this study was to compare efficacy and safety of the new ThermoCool Surround Flow® catheter (SFc) versus the ThermoCool® (TCc) in achieving persistent circumferential electrical isolation of the pulmonary veins (PVs) in patients with paroxysmal atrial fibrillation (AF). Methods and Results: This multicenter, randomized, controlled study enrolled patients suffering from paroxysmal AF. Randomization was run in a one‐to‐one fashion between radiofrequency ablation by TCc or SFc. Aim of PVs ablation was documentation of electrical isolation with exit/entrance block recorded on a circular catheter. Among the 106 enrolled patients, 52 (49.0%) were randomized to TCc and 54 (51.0%) to SFc. Total volume of infused saline solution during the procedure was lower in the SFc than in TCc group (752.7 ± 268.6 mL vs 1,165.9 ± 436.2 mL, P < 0.0001). Number of identified and isolated PVs was similar in the 2 groups. Number of PVs remaining isolated 30 minutes after ablation was higher in the SFc than in TCc group (95.2% vs 90.5%, P < 0.03), mainly driven by acute ablation result in the left PVs (96.1% vs 89.7%, P < 0.04). Complications were seldom and observed only in the TCc group (0% vs 3.84%, P < 0.03). At 6‐month follow‐up SFc patients reported a trend toward less AF recurrences compared to those in the TCc group (22.9% vs 27.0%, P = 0.69). Conclusion: PV isolation by SFc lowered the rate of left PV early reconnections and reduced the volume of infused saline solution while maintaining the safety profile of AF ablation. (J Cardiovasc Electrophysiol, Vol. 24, pp. 269‐273, March 2013)  相似文献   
3.
The aim of the present study was to evaluate the coexpression of very early (CD69), early (CD25) and late (HLADR) antigens and to analyse the mean fluorescence intensity (MFI) of such activation markers on synovial fluid (SF) and peripheral blood (PB) lymphocytes of patients affected by rheumatoid arthritis (RA) and other types of chronic synovitis (OCS). A three colour cytometric analysis was performed using a peridinin chlorophyll protein conjugated anti-CD3 antibody in combination with fluorescein isothiocyanate or phycoerythrin labelled anti-CD69, anti-HLADR, anti-CD25 monoclonal antibodies (mAbs). A T cell gating method was utilized, so that three sets of bivariant dot plot quadrant displays were obtained (CD69/HLADR, CD69/CD25, CD25/HLADR). A large percentage of SF T lymphocytes in RA showed the coexpression of very early and late activation antigens (CD3 + CD69 + HLADR +), whereas CD3 + CD69 + CD25 + bearing cells and CD3 + CD25 + HLADR + lymphocytes were only a small percentage. Similar results were obtained in patients with OCS, although to a lesser extent. No statistically significant differences in MFI of CD69 and HLADR positive SF T cells between RA and OCS were observed. The CD69 + CD25-HLADR + T cell subset is the most commonly represented in the synovial environment, among those we have evaluated; this phenotype may be characteristic of chronic inflammatory arthritis.  相似文献   
4.
5.
Study Objective: To evaluate the relationship between acute response to cardiac resynchronization therapy (CRT) and long-term clinical outcome in patients with drug refractory heart failure.
Methods and Results: In 28 patients undergoing CRT implant, left ventricular (LV) dyssynchrony was evaluated by tissue Doppler imaging (TDI)-derived longitudinal strain by mean of septum-lateral basal asynchrony index (S-Li) and basal delayed longitudinal contraction (DLC). TDI measurements were made before, and 30 minutes and 1 year after implant. Baseline and 1-year follow-up New York Heart Association (NYHA) functional class, 6-minute walking test (6-MWT) distance, and quality of life (QoL) score were measured. Responders (n = 22) were defined by a ≥ 1 decrease in NYHA functional class and 6-MWT ≥25% at 1 year. At baseline, no differences were observed between responders and nonresponders in clinical and echocardiographic measurements. LV dyssynchrony acutely recovered only in responders 30 minutes after implantation, with a significant reduction in S-Li and DLC. Moreover, the percent decreases in S-Li and DLC were highly correlated with those observed in NYHA class (r = 0.70, and r = 0.81, respectively, P < 0.001), 6-MWT (r = 0.59, and r = 0.57, respectively, P < 0.001 and P < 0.01), and QoL score (r = 0.71, and r = 0.83, respectively, p < 0.001) at 1-year follow-up.
Conclusions: Acute recovery of LV intraventricular dyssynchrony is a major discriminator between responders and nonresponders to CRT, which strongly correlates with a favorable long-term clinical outcome.  相似文献   
6.
Background: The role of pulmonary veins (PV) isolation in patients with persistent atrial fibrillation (AF) is still debated. The aim of this study was to evaluate the adjunctive role of PV isolation in patients with persistent AF who underwent circumferential PV ablation (anatomical approach).
Methods: We treated 97 consecutive patients presenting with drug-refractory persistent AF by an anatomical approach (group A, n = 36, mean age = 60 ± 8 years, 29 males) or an integrated approach (group B, n = 61, mean age 59 ± 10 years, 48 males). In all patients, radiofrequency (RF) ablation was performed by means of a nonfluoroscopic navigation system, in order to anatomically create circumferential lines around the PV. In group B, the persistence of PV potentials was ascertained with a multipolar circular catheter. If PV potentials persisted, RF energy targeting the electrophysiological breakthroughs was delivered to disconnect the PV. Past a 2-month period of observation, success was defined as absence of any atrial tachyarrhythmia recurrence lasting >30 seconds.
Results: Total procedure duration (220 ± 62 minutes vs 140 ± 43 minutes, P < 0.001), fluoroscopy time (35 ± 15 minutes vs 17 ± 9 minutes, P < 0.001), and RF delivery time (48 ± 22 minutes vs 27 ± 9 minutes, P < 0.001) were significantly longer in group B than in group A. One cardiac perforation occurred in group A. After 15 ± 9.1 months, 21 patients in group A (58%) and 34 patients in group B (56%) were free of atrial tachyarrhythmia recurrence (P = 0.9).
Conclusions: In patients with persistent AF, who underwent an anatomical approach, electrophysiological confirmation of PV disconnection significantly increased the fluoroscopy and procedural times, without effect on the long-term outcomes.  相似文献   
7.
Objectives: The use of antiarrhythmic drugs after ablation is a controversial issue when evaluating the efficacy of atrial fibrillation (AF) ablation. This study compares in a prospective and randomized fashion the impact of an antiarrhythmic drug in preventing AF recurrence after AF ablation.
Methods: From February 2004 to May 2005, 107 consecutive patients (mean age 57 ± 10 years, 69 men), with paroxysmal (60%) or persistent (40%) drug refractory AF, were randomly assigned to ablation alone (Group A, 53 patients) or combined with the best antiarrhythmic therapy, preferably amiodarone (Group B, 54 patients). All patients underwent cavo-tricuspid and left inferior pulmonary vein (PV)-mitral isthmus ablation plus circumferential PV ablation, using a guided electro-anatomical approach. Standard electrocardiograms (ECG), and ambulatory and transtelephonic ECG monitoring were used to assess AF recurrences. Recurrences during the first month after ablation were excluded from this analysis.
Results: At 12 months of follow-up, no significant difference was observed in the rates of AF recurrences between Group A (18/53 patients, 34%) and Group B (16/54 patients, 30%). The percentage of patients with ≥1 asymptomatic AF episode was higher in Group B than in Group A (10/16 patients, 63%, vs 5/18 patients, 28%, P = 0.04).
Conclusions: Continuing antiarrhythmic drug therapy in patients who undergo catheter ablation for AF did not lower the rate of AF recurrences. Antiarrhythmic drugs increased the proportion of patients with asymptomatic AF episodes.  相似文献   