1.

Background

To study the efficacy of inside-out technique in completely eradicating the cholesteatoma from middle ear and mastoid, preservation of hearing & and quality of life post mastoidectomy with regards to recurrent discharge, wax, granulations.

Material and methods

Non-randomized, prospective, observational study performed at the Department of ENT in our hospital. In the study we included 100 patients presenting with chronic suppurative otitis media with cholesteatoma, they underwent inside out mastoidectomy and were followed up till the end of the study to evaluate the efficacy of inside out mastoidectomy in eradicating the disease from the middle ear cleft. To assess preservation of hearing and to assess cavity problems.

Results

Of the 100 patients, 98 patients had a total clearance of disease by the inside out approach, and 2 patients, had doubtful clearance. All patients came for regular follow up and none of them had residual disease at the end of the study period. Thus, the overall success rate was 100% in our study. A significant improvement in the mean air conduction (p?<?0.01) and the mean air bone gap (p?<?0.01) was seen in all postoperatively at 3rd month PTA. Only one patient had conductive hearing loss one and a half years postoperatively after initial improvement. A dry self-cleansing cavity was achieved in 95% of the patients and only 5% required regular cleaning of wax the cavities.

Conclusion

Inside out mastoidectomy is a better alternative in canal wall down procedures as it not only clears the disease from the middle ear cleft, but also leaves behind a small postoperative cavity, which will preserve the hearing, decrease the cavity problems and increase the quality of life of such patients.  相似文献   
2.
3.
GeroScience - Lysosomes are crucial for degradation and recycling of damaged proteins and cellular components. Therapeutic strategies enhancing lysosomal function are a promising approach for aging...  相似文献   
4.
BACKGROUNDThe critical shoulder angle (CSA) is a radiographic measurement that provides an assessment of both glenoid inclination and acromial length. Higher values may correlate with the presence of rotator cuff tears. However, it is difficult to obtain a high-quality true anteroposterior (AP) radiograph of the shoulder, with any excess scapular version or flexion/extension resulting in deviation from the true CSA value. Three-dimensional (3D) bony reconstructions of computed tomography (CT) shoulder scans may be able to be rotated to obtain a similar view to that of true AP radiographs.AIMTo compare CSA measurements performed on 3D bony CT reconstructions, with those on corresponding true AP radiographs.METHODSCT shoulder scans were matched with true AP radiographs that were classified as either Suter-Henninger type A or C quality. 3D bony reconstructions were segmented from the CT scans, and rotated to replicate an ideal true AP view. Two observers performed CSA measurements using both CT and radiographic images. Measurements were repeated after a one week interval. Reliability was assessed using intraclass correlation coefficients (ICCs) and Bland-Altman plots [bias, limits of agreement (LOA)].RESULTSTwenty CT shoulder scans were matched. The mean CSA values were 32.55° (± 4.26°) with radiographs and 29.82° (± 3.49°) with the CT-based method [mean difference 2.73° (± 2.86°); P < 0.001; bias +2.73°; LOA -2.17° to +7.63°]. There was a strong correlation between the two methods (r = 0.748; P < 0.001). Intra-observer reliability was similar, but the best intra-observer values were achieved by the most experienced observer using the CT-based method [ICC: 0.983 (0.958-0.993); bias +0.03°, LOA -1.28° to +1.34°]. Inter-observer reliability was better with the CT-based method [ICC: 0.897 (0.758-0.958), bias +0.24°, LOA -2.93° to +3.41°].CONCLUSIONThe described CT-based method may be a suitable alternative for critical shoulder angle measurement, as it overcomes the difficulty in obtaining a true AP radiographic view.  相似文献   
5.
The most stable pattern of internal fixation for fractures of the mandibular condyle is a matter for ongoing discussion. In this study we investigated the stability of three commonly used patterns of plate fixation, and constructed finite element models of a simulated mandibular condylar fracture. The completed models were heterogeneous in the distribution of bony material properties, contained about 1.2 million elements, and incorporated simulated jaw-adducting musculature. Models were run assuming linear elasticity and isotropic material properties for bone. This model was considerably larger and more complex than previous finite element models that have been used to analyse the biomechanical behaviour of differing plating techniques. The use of two parallel 2.0 titanium miniplates gave a more stable configuration with lower mean element stresses and displacements over the use of a single miniplate. In addition, a parallel orientation of two miniplates resulted in lower stresses and displacements than did the use of two miniplates in an offset pattern. The use of two parallel titanium plates resulted in a superior biomechanical result as defined by mean element stresses and relative movement between the fractured fragments in these finite element models.  相似文献   
6.
IntroductionMost rhinologic procedures, particularly endoscopic sinonasal procedures, are liable to produce aerosols. The severe acute respiratory syndrome coronavirus 2 (SARS-Co V-2) transmits via respiratory droplets, but the degree of its spread through airborne routes by aerosol is unclear.ObjectiveThe aim of this article is to counsel rhinologists on how to modify their conventional practice during the COVID-19 pandemic by prioritising the need of procedures, identifying aerosol- generating procedures and using precise personal protection equipment for various endonasal procedures.MethodsWe did a review of articles indexed for MEDLINE on PubMed, ENT Cochrane, DOAJ and Web of Science databases using the keywords nasal endoscopy, SARS‐CoV‐2, COVID‐19, aerosol generating medical procedures and rhinology to formulate guidelines for the safety of healthcare workers.ResultsThe review included evidence from 28 articles from the otorhinolaryngology, surgery, infectious disease, head and neck surgery and cancer biology literature. We have provided recommendations and relevant information for rhinologists during the COVID-19 pandemic, based on the available studies and data, to warrant high-quality patient care and requisite levels of infection prevention during rhinology procedures.ConclusionIn rhinology, marked care is advised during nasal packing, electrocauterisation and use of high-speed rotating devices in potentially infected tissue as they are considerable aerosol- producing procedures. The choice of personal protective equipment is based on the risk of exposure and possible modes of aerosol generation.  相似文献   
7.
There has been increasing interest in nutraceutical augmentation strategies to boost the efficacy of antidepressants. This study assessed whether S-adenosylmethionine (SAMe), a methyl donor that occurs naturally in the body, may be of such benefit. We conducted an 8-week, double-blind RCT in which 107 treatment non-remittent outpatients with DSM-5 diagnosed Major Depressive Disorder (MDD) were randomized to either SAMe or placebo adjunctively to antidepressants. One-carbon cycle nutrients, pertinent single nucleotide polymorphisms (SNPs), and BDNF were also analysed as potential moderators of response. A linear mixed-effects model revealed a significant overall reduction in Montgomery-Asberg Depression Rating Scale (MADRS) score across time, however there was no significant between-group difference observed (p?=?0.51). Response rates at Week 8 were 54.3% in the SAMe group and 50.0% in the placebo group, with remission rates 43.5% for SAMe and 38.3% for placebo (all results NS). No effect of SAMe was found on any secondary outcome. Differential response to SAMe was not modified by a range of key genotypes (e.g. COMT), nor reflected in a change of homocysteine, red cell folate, or BDNF. Use of SAMe elicited no significant adverse effects beyond placebo, however it was implicated in one case of serotonin syndrome-like symptoms. This study concludes that 800?mg/day of SAMe is not an effective adjunctive treatment in MDD, and no obvious biomarker reflected any differential response to treatment. Due to such a distinctly high placebo-response (despite rigorous screening), future studies should employ a placebo run-in period and other strategies to minimize placebo response.  相似文献   
8.
Animal models are frequently used to elucidate pathomechanism and pathophysiology of various disorders of the human intervertebral disc (IVD) and also to develop therapeutic approaches. Here we report morphological characteristics of the kangaroo lumbar IVDs and compare them with other animal models used in spine research. Twenty-five fresh-frozen cadaveric lumbar spines (T12–S1) derived from kangaroo carcases (Macropus giganteus) of undetermined age were first scanned in a C-Arm X-ray machine. A photograph of the axial section of the disc including a calibrated metric scale was also acquired. The digital radiographs and photographs were processed in ImageJ to determine the axial and sagittal plane dimensions for the whole disc (WD) and the nucleus pulposus (NP) and the mid-sagittal disc height for all the lumbar levels. Our results suggest that the L6–S1 IVD in kangaroos is distinctly large compared with the upper lumbar IVDs. Based on previously published data, human lumbar IVDs are the largest of all the animal IVDs used in spine research, with camelid cervical IVDs being the closest relative in absolute dimensions (llamas: 78% in disc height, 40% in WD volume, and 38% in NP volume). Kangaroo L6–S1 IVD was approximately 51% in height, 20% in WD volume, and 20% in NP volume of the human lumbar IVD. We conclude that morphological similarities exist between a kangaroo and human lumbar IVD, especially with the lima bean shape in the axial plane, wedge shape in the sagittal plane, convexity at the cephalad endplates, and percentage volume occupied by the NP in the IVD. These slides can be retrieved under Electronic Supplementary Material.  相似文献   
9.
10.
The essential oil composition of Angelica glauca roots   总被引:1,自引:0,他引:1  
The essential oil of Angelica glauca roots was analysed by GC and GC/MS. Sixty-eight constituents representing about 92% of the oil were identified. The main constituents of the oil are beta-phellandrene (15.29%) and (Z)-ligustilide (31.55%).  相似文献   