首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
口腔科学   13篇
  2021年   1篇
  2011年   1篇
  2007年   2篇
  2005年   4篇
  2004年   1篇
  2003年   2篇
  2000年   2篇
排序方式: 共有13条查询结果,搜索用时 109 毫秒
1.
Odontology - Recording fluorescence using flash photography, may help reduce time of capture and apply effectively in clinical practice. To test methods for visualizing composite resins...  相似文献   
2.
This research quantitatively evaluated the marginal adaptation of pit and fissure sealants. The occlusal surfaces of 48 intact, caries-free human molars were cleaned with an air-abrasion unit. The teeth were then randomly divided into eight groups of six teeth each according to the type of enamel conditioning, sealant material applied and curing unit used. After applying either 40% phosphoric acid gel (K-etch, Kuraray Co) or a self-etching primer adhesive system (Clearfil SE Bond, Kuraray Co), sealant materials of two viscosities were applied (Teethmate F-1 and Protect-Liner-F, Kuraray Co) and cured with halogen (Optilux 500, Demetron) or plasma arc (Apollo-95E, Dental & Medical Diagnostic Systems, Ltd) curing units. The marginal adaptation of the pit and fissure sealant restorations was evaluated by using a computer-assisted quantitative margin analysis in a scanning electron microscope (SEM) on epoxy replicas before and after thermal and mechanical stressing of the teeth. The results were statistically analyzed with one-way analysis of variance (ANOVA) at a confidence level of 95% (p=0.05). A post-hoc Tukey HSD-test was used for multiple pairwise comparisons between groups. The null hypothesis was that there was no statistically significant difference between the groups that were tested in this study. The statistically significant differences between groups were more pronounced after loading. In most cases, the self-etching adhesive system (SE Bond) proved as effective as phosphoric acid etching (K-etch). The low viscosity sealant material (Teethmate F-1), in most cases, exhibited better marginal adaptation than the high viscosity material (Protect-Liner F). The high viscosity material performed equally well only when used in combination with the self-etching primer adhesive system as an intermediate layer. The halogen curing unit (Optilux 500) led to better marginal adaptation than the plasma arc curing unit (Apollo 95E), especially after thermal and mechanical stressing.  相似文献   
3.
PURPOSE: The purpose of this study was to assess the effect of different high-palladium alloys on the resulting color of opaque porcelain. Three Pd-Cu-Ga alloys, Spartan Plus (S; Williams Dental Co/Division of Ivoclar North America, Amhest, NY), Liberty (B; J.F. Jelenko & Co, Armonk, NY), and Freedom Plus (F; J.F. Jelenko & Co); 4 Pd-Ga alloys, Legacy (L; J.F. Jelenko & Co), IS 85 (I; Williams Dental Co), Protocol (P; Williams Dental Co), and Legacy XT (X; J.F. Jelenko & Co); and a Pd-Ag alloy, Super Star (T; J.F. Jelenko & Co), were examined. The Au-Pd alloy Olympia (O; J.F. Jelenko & Co) served as the control. MATERIALS AND METHODS: Three cast 16-mm discs, 1-mm thick, were prepared from each of the alloys. After metallurgically polishing and air-abrading, the specimens were oxidized following the manufacturer's recommendations. Shade B1 opaque porcelain (Vita-Omega; Vident, Baldwin Park, CA) was applied at a final thickness of 0.1 mm using a mold. After 2 opaque porcelain firing cycles, the surfaces were air-abraded. The colors of the specimens were measured using a colorimeter and expressed in Commission International de l'Eclairage (CIE) L*a*b* coordinates. Color differences (delta E) were determined between the control and each experimental group. Analysis of Variance and Tukey-Kramer tests were performed on the delta E data. RESULTS: The 3 Pd-Cu-Ga alloys showed significantly greater (p < .01) delta E values (S = 2.8 +/- 1.1, B = 3.0 +/- 0.6, and F = 2.1 +/- 0.2) than the remaining 5 experimental groups (L = 0.7 +/- 0.5, I = 0.7 +/- 0.4, P = 0.7 +/- 0.2, X = 0.7 +/- 0.4, and T = 0.7 +/- 0.5). The directions of the significant color changes were relatively equally distributed along the L*, a*, and b* axes, and all delta L*, delta a*, and delta b* values were negative (lower value, more green and blue relative to control O). CONCLUSIONS: This work suggests that a 0.1-mm-thick layer of opaque porcelain in the Pd-Cu-Ga alloys studied, did not reliably reproduce the color of porcelain.  相似文献   
4.
5.
The aims of this study were, first, to measure shrinkage induced by different methods of pulse-delay light curing and, second, to verify their influence on the marginal adaptation of class V restorations in enamel and dentin. Eight groups, comprising seven groups (n = 6) with different pulse-delay parameters and a control group, were compared for dynamic linear displacement and force by using a fine hybrid composite. Based on these results, the pulse-delay curing procedure with the lowest shrinkage force was chosen and tested against the control group with respect to marginal adaptation in class V restorations (n = 8) before and after simultaneous thermal and mechanical loading. Statistically significant differences between groups were found for both shrinkage properties tested, with one pulse-delay group giving the lowest overall shrinkage values. However, the percentages of 'continuous margin' of this group, and of the control before and after loading, were not significantly different in dentin, whereas a significantly lower percentage of 'continuous margin' was detected in the pulse-delay group in enamel after loading.  相似文献   
6.
This article describes a laboratory procedure for the visual evaluation of interarch space and its effect on implant prosthesis design. The method is applicable to patients presenting with completely edentulous arches. Silicone impression material is used to form a resilient cast and an external mold from an existing denture. The denture is duplicated using autopolymerizing acrylic resin. The duplicate denture and resilient cast are mounted on an articulator. Spatial relationships of anatomic landmarks can be evaluated, and a quantitative evaluation of available space can be made. The duplicate denture can also be used as a surgical template to direct implant placement. Reference tables are provided to serve as guidelines in the correlation between available space and minimum space required for various implant-assisted restorations.  相似文献   
7.
This in vitro study compared the marginal and internal adaptation of bulk-filled Class I and cuspal coverage direct resin composite restorations filled with different types of adhesive restorative systems and different thicknesses of bonding agent. Seventy-two intact, caries-free, freshly extracted human molars were randomly divided into 12 groups of six teeth each, according to the type of cavity (Class I [I] or Cuspal Coverage [C]), adhesive restorative system (SE Bond/Clearfil AP-X [SE] or Prime&Bond NT/Spectrum TPH [PB]) and thickness of bonding agent (normal or thick layer) in Class I restorations. Standardized Class I and Cuspal coverage cavities with enamel outer margins were prepared and restored with the corresponding type and thickness of bonding agent and respective resin composite. The resin composite was placed and polymerized in one increment (bulk filling). Dentinal fluid was simulated using 1:3 diluted horse serum and fed into the pulp chamber both during restoration and stressing. In six of the 12 groups, the restorations were subjected to 1.2 million mechanical occlusal cycles (maximum force 49 N; frequency 1.7Hz) and 3,000 simultaneous thermal cycles (5-50-5 degrees C). Marginal adaptation before and after mechanical and thermal stressing was assessed by using the replica technique and quantitative evaluation under SEM at 200x magnification. The teeth were dissected in a mesio-distal direction with a slow rotating diamond disc under water cooling, and the internal adaptation was also assessed by using the replica technique under the conditions described. Statistical evaluation of the continuous margin at the external and internal interface was performed with one-way analysis of variance (ANOVA) and Tukey's Studentized Range (HSD) test (p = 0.05). Even though Cuspal coverage restorations (SE- C: 96.89 +/- 1.83 and PB- C: 97.15 +/- 2.93) exhibited statistically significantly better external adaptation than Class I restorations (SE- I: 63.95 +/- 12.82 and PB- I 64.74 +/- 14.62) before stressing, there was no statistically significant difference after mechanical and thermal stressing (SE- C: 76.35 +/- 18.53 and PB- C: 76.02 +/- 12.49 SE- I: 54.67 +/- 10.82 and PB- I: 59.94 +/- 15.20). After stressing, SE Bond Cuspal coverage restorations (SE- C: 96,72 +/- 3,26) exhibited superior internal adaptation compared to SE Bond Class I restorations (SE- I: 57.83 +/- 12.91). No difference was observed in internal adaptation between Prime&Bond NT Cuspal coverage and Class I restorations (PB- C:36.46 +/- 21.82, PB- I: 38.71 +/- 6.76). In Class I restorations, the increased thickness in bonding did not improve the marginal and internal adaptation either before or after stressing. Bulk-filled direct resin composite Cuspal coverage restorations exhibited marginal adaptation similar to bulk-filled direct resin composite Class I restorations. The internal adaptation of Cuspal coverage SE Bond/Clearfil AP-X restorations was superior to all the other groups tested.  相似文献   
8.
PURPOSE: To evaluate the marginal adaptation of mixed Class V cavities restored with Clearfil Protect Bond (Kuraray), Clearfil SE Bond (Kuraray), and two experimental combinations of both marketed adhesives, after fatigue and water storage. MATERIALS AND METHODS: Four groups (Clearfil Protect Bond, Clearfil SE Bond, Exp. 1 and Exp. 2) of Class V cavities were restored with a microhybrid restorative composite (Clearfil APX, Kuraray). The marginal quality of these restorations was quantified by evaluation of gold-coated epoxy replicas with scanning electron microscopy before loading, after loading, and after a 12-month period of water storage. Data from marginal adaptation along the total margin length, on enamel, and on dentin were analyzed with the Wilcoxon signed rank test for differences within a group and with Kruskal-Wallis in order to assess the differences between groups. The Bonferroni test was used for post-hoc comparisons, and the confidence level was set to 95%. RESULTS: The mean percentages (+/-SD) of "continuous margin" of the total marginal length ranged from 79.5% (+/-13.3) to 62.2% (+/-10.4) and from 70% (+/-11) to 61% (+/-15.1) after loading and after storage, respectively. No significant differences could be detected amongthe different groups. However, the marginal adaptation of Clearfil Protect Bond remained the most stable of all materials tested, as no significant differences were detected between the percentages of continuous margins before loading, after loading, or after storage. CONCLUSIONS: The use of an antibacterial adhesive system was as effective as the conventional two-step self-etching adhesive in the marginal adaptation of Class V restorations.  相似文献   
9.
This study measured the linear polymerization displacement and polymerization forces induced by polymerization shrinkage of a series of flowable resin-based restorative materials. The materials tested were 22 flowable resin-based restorative materials (Admira Flow, Aelite Flow, Aeliteflow LV, Aria, Crystal Essence, Definite Flow, Dyract Flow, Filtek Flow, FloRestore, Flow-it, Flow-Line, Freedom, Glacier, OmegaFlo, PermaFlo, Photo SC, Revolution 2, Star Flow, Synergy Flow, Tetric Flow, Ultraseal XT and Wave). Measurements for linear polymerization displacement and polymerization forces were performed using custom made measuring devices. Polymerization of the test materials was carried out for 60 seconds by means of a light curing unit, and each property was measured for 180 seconds from the start of curing in eight specimens for each material. Statistical evaluation of the data was performed with one-way analysis of variance (ANOVA), Tukey's Studentized Range (HSD) test (p=0.05) and simple linear regression. A wide range of values was recorded for linear polymerization displacement (26.61 to 80.74 microns) and polymerization forces (3.23 to 7.48 kilograms). Statistically significant differences among materials were found for both properties studied. Very few materials (Freedom, Glacier, and Photo SC) presented low values of linear polymerization displacement and polymerization forces (similar to hybrid resin composites), while the majority of materials presented very high values in both properties studied. Study of the shrinkage kinetics revealed the exponential growth process of both properties. The polymerization forces development exhibited a few seconds delay over linear polymerization displacement. Simple linear regression showed that the two polymerization shrinkage properties that were studied were not highly correlated (r2=0.59).  相似文献   
10.
STATEMENT OF PROBLEM: The color of dental porcelain depends on the type of metal substrate. Little research has been done to document the effects of different types of high-palladium alloys on the color of dental porcelain. PURPOSE: The purpose of this in vitro study was to evaluate the effects of different high-palladium alloys on the resulting color of dentin porcelain, as well as on that of opaque porcelain after simulated dentin and glazing firing cycles. MATERIAL AND METHODS: Three Pd-Cu-Ga alloys, Spartan Plus (S), Liberty (B), and Freedom Plus (F), and 5 Pd-Ga alloys, Legacy (L), IS 85 (I), Protocol (P), Legacy XT (X), and Jelenko No.1 (N), were examined. A Pd-Ag alloy, Super Star (T), was included for comparison to the high-palladium alloys, and the Au-Pd alloy, Olympia (O), served as the control. Six cast discs (16 x 1 mm) were prepared from each of the alloys. Shade B1 opaque porcelain (Vita-Omega) was applied at a final thickness of 0.1 mm. After 2 opaque porcelain firing cycles, the surfaces were airborne-particle abraded, and the specimens were divided into 2 groups. In the first group, 0.9 mm of B1 dentin porcelain was applied. The other group of specimens with only opaque porcelain underwent the same dentin porcelain and glazing firing cycles. Color differences (DeltaE) were determined with a colorimeter between the control and each experimental group, after the second opaque porcelain, second dentin porcelain, and glazing firing cycles. One-way analysis of variance and Dunnett's multiple range test were performed on the DeltaE data (alpha=.05). RESULTS: After the application of dentin porcelain, the 3 Pd-Cu-Ga alloys showed significantly different (P<.05) DeltaE values (S=2.3 +/- 0.5, B=1.4 +/- 0.3, and F=1.3 +/- 0.7) than the control group. After the glazing cycle of this group, the 3 Pd-Cu-Ga alloys and the Pd-Ag alloy exhibited significantly different (P<.05) DeltaE values (S=2.8 +/- 0.8, B=2.2 +/- 0.3, F=1.9 +/- 1.0, and T=1.4 +/- 0.5) than the control group. After the simulated dentin porcelain firing cycles, the specimens with only opaque porcelain exhibited significantly different (P<.05) DeltaE values (S=5.2 +/- 1.4, B=5.4 +/- 0.6, and F=3.9 +/- 0.2) than the control group. The color difference between the 3 Pd-Cu-Ga alloys with only opaque porcelain and the control group increased more after the simulated glazing cycle (S=6.6 +/- 1.5, B=6.3 +/- 0.5, and F=4.6 +/- 0.1). The observed color differences between the Pd-Ga alloys and the control group were not statistically significant at any point. CONCLUSIONS: The Pd-Cu-Ga alloys with only opaque porcelain, after the simulated dentin porcelain and glazing firing cycles, exhibited clinically unacceptable color differences. The application of dentin porcelain to the Pd-Cu-Ga alloys resulted in clinically acceptable color differences. The application of dentin porcelain to the Pd-Ag alloy, after the glazing firing cycle, resulted in clinically acceptable color differences (approximately 2.8 to 3.7 DeltaE CIELAB units). The Pd-Ag alloy specimens with only opaque porcelain did not exhibit significant color differences from the control group, whereas significant color differences from the control group after the dentin porcelain and glazing firing cycles were still clinically acceptable.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号