首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   17篇
  免费   0篇
基础医学   1篇
口腔科学   4篇
临床医学   3篇
外科学   8篇
预防医学   1篇
  2021年   1篇
  2015年   1篇
  2012年   2篇
  2009年   1篇
  2007年   1篇
  2006年   2篇
  2005年   2篇
  2004年   2篇
  2003年   2篇
  2002年   1篇
  2000年   1篇
  1999年   1篇
排序方式: 共有17条查询结果,搜索用时 15 毫秒
1.

The purpose of this study was to assess the effect of a chitosan-based nanoformulation containing green tea on leathery (remaining) dentin subsurface microhardness. Size distribution, polydispersity index (PDI) and zeta potential (mV) of nanoformulations were previously determined by dynamic light scattering (DLS). Human dentin specimens were exposed to Streptococcus mutans for 14 d. Soft dentin were selectively removed by Er:YAG laser (n?=?30) or bur (n?=?30). Remaining dentin was biomodified with chitosan nanoparticles (Nchi, n?=?10) or green tea-loaded chitosan nanoparticles (Gt?+?Nchi, n?=?10) for 1 min. Control group (n?=?10) did not receive any treatment. Subsurface microhardness (Knoop) was evaluated in hard (sound) and soft dentin, and then, in leathery dentin and after its biomodification, at depths of 30, 60 and 90 μm from the surface. Nchi reached an average size of?≤?300 nm, PDI varied between 0.311 and 0.422, and zeta potential around?+?30 mV. Gt?+?Nchi reached an average size of?≤?350 nm, PDI?<?0.45, and zeta potential around?+?40 mV. Soft dentin showed significantly reduced microhardness at all depths (p?>?0.05). The subsurface microhardness was independent of choice of excavation method (p?>?0.05). At 30 µm from the surface, Gt?+?Nchi increased the leathery dentin microhardness compared to untreated group (p?<?0.05). Nchi promoted intermediate values (p?>?0.05). Both nanoformulations showed an average size less than 350 nm with nanoparticles of different sizes and stability along the 90-day period evaluated. Subsurface microhardness of bur-treated and laser-irradiated dentin was similar. At 30 µm, the biomodification with Gt?+?Nchi improved the microhardness of leathery dentin, independently of caries excavation method used.

  相似文献   
2.
Femtosecond lasers have been widely used in laser surgery as an instrument for contact-free tissue removal of hard dental, restorative materials, and osseous tissues, complementing conventional drilling or cutting tools. In order to obtain a laser system that provides an ablation efficiency comparable to mechanical instruments, the laser pulse rate must be maximal without causing thermal damage. The aim of this study was to compare the different morphological characteristics of the hard tissue after exposure to lasers operating in the femtosecond pulse regime. Two different kinds of samples were irradiated: dentin from human extracted teeth and bovine femur samples. Different procedures were applied, while paying special care to preserving the structures. The incubation factor S was calculated to be 0.788±0.004 for the bovine femur bone. These results indicate that the incubation effect is still substantial during the femtosecond laser ablation of hard tissues. The plasma-induced ablation has reduced side effects, i.e., we observe less thermal and mechanical damage when using a superficial femtosecond laser irradiation close to the threshold conditions. In the femtosecond regime, the morphology characteristics of the cavity were strongly influenced by the change of the effective number of pulses.  相似文献   
3.
Lasers in Medical Science - Low-level laser therapy (LLLT) has been widely applied in pain relief in several clinical situations, including temporomandibular disorders (TMD). However, the effects...  相似文献   
4.
BACKGROUND AND OBJECTIVES: Bone remodeling is characterized as a cyclic and lengthy process. It is currently accepted that not only this dynamics is triggered by a biological process, but also biochemical, electrical, and mechanical stimuli are key factors for the maintenance of bone tissue. The hypothesis that low-level laser therapy (LLLT) may favor bone repair has been suggested. The purpose of this study was to evaluate the bone repair in defects created in rat lower jaws after stimulation with infrared LLLT directly on the injured tissue. STUDY DESIGN/MATERIALS AND METHODS: Bone defects were prepared on the mandibles of 30 Holtzman rats allocated in two groups (n = 15), which were divided in three evaluation period (15, 45, and 60 days), with five animals each. control group-no treatment of the defect; laser group-single laser irradiation with a GaAlAs semiconductor diode laser device (lambda = 780 nm; P = 35 mW; t = 40 s; Theta = 1.0 mm; D = 178 J/cm(2); E = 1.4 J) directly on the defect area. The rats were sacrificed at the pre-established periods and the mandibles were removed and processed for staining with hematoxylin and eosin, Masson's Trichrome and picrosirius techniques. RESULTS: The histological results showed bone formation in both groups. However, the laser group exhibited an advanced tissue response compared to the control group, abbreviating the initial inflammatory reaction and promoting rapid new bone matrix formation at 15 and 45 days (P<0.05). On the other hand, there were no significant differences between the groups at 60 days. CONCLUSION: The use of infrared LLLT directly to the injured tissue showed a biostimulating effect on bone remodeling by stimulating the modulation of the initial inflammatory response and anticipating the resolution to normal conditions at the earlier periods. However, there were no differences between the groups at 60 days.  相似文献   
5.
This study aimed to evaluate the effectiveness of low intensity laser therapy (LILT) in 30 patients presenting temporomandibular joint (TMJ) pain and mandibular dysfunction in a random and double-blind research design. The sample, divided into experimental group (1) and placebo group (2), was submitted to the treatment with infrared laser (780 nm, 30 mW, 10 s, 6.3 J/cm(2)) at three TMJ points. The treatment was evaluated throughout six sessions and 15, 30 and 60 days after the end of the therapy, through visual analogue scale (VAS), range of mandibular movements and TMJ pressure pain threshold. The results showed a reduction in VAS (p < 0.001) and through the ANOVA with repeated measures it was observed that the groups did not present statistically significant differences (P = 0.2060), as the averages of the evaluation times (P = 0.3955) and the interaction groups evaluation times (P = 0.3024), considering the MVO. The same occurred for RLE (P = 0.2988, P = 0.1762 and P = 0.7970), LLE (P = 0.3265, P = 0.4143 and P = 0.0696), PPTD (P = 0.1558, P = 0.4695 and P = 0.0737) and PPTE (P = 0.2376, P = 0.3203 and P = 0.0624). For PE, there were not statistically significant differences for groups (P = 0.7017) and the interaction groups evaluation times (P = 0.6678), even so in both groups the PE varied with time (P = 0.0069).  相似文献   
6.
7.
The purpose of our investigation is to compare the intrapulpal temperature changes following blue LED system and halogen lamp irradiation at the enamel surface of permanent teeth. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Several light sources can be used: halogens, arc plasma, lasers, and recently blue LED systems. An important aspect to be observed during such a procedures is the temperature change. In this study, we have used nine human extracted permanent teeth: three central incisors, three lateral incisors, and three canines. Teeth were exposed to two light sources: blue LED system (preliminary commercial model LEC 470-II) and halogen lamp (conventional photo-cure equipment). The surface of teeth was exposed for 20, 40, and 60 sec at the buccal and lingual enamel surface with an angle of 45 degrees. Temperature values measured by a thermistor placed at pulpar chamber were read in time intervals of 1 sec. We obtained plots showing the temperature evolution as a function of time for each experiment. There is a correlation between heating quantity and exposition time of light source: with increasing exposition time, heating increases into the pulpal chamber. The halogen lamp showed higher heating than the LED system, which showed a shorter time of cooling than halogen lamp. The blue LED system seems like the indicated light source for photo-cure of composite resin during the bonding of brackets. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Blue LED equipment did not heat during its use. This could permit a shorter clinical time of operation and better performance.  相似文献   
8.
9.
OBJECTIVE: We have investigated and compared the main morphological features of human enamel tissue under Nd:YAG nanosecond and picosecond laser ablation. BACKGROUND DATA: The use of ultrashort laser pulses on teeth ablation is an alternative to avoid overheating and presents the advantage of minimizing the volume of damaged material during laser ablation. Comparison of the morphology obtained in laser ablation using nanosecond and picosecond laser pulses is a way to investigate the advantages of ultrashort laser pulses for ablation. METHODS: Trains of pulses with picosecond duration from a Q-switched and mode-locked Nd:YAG laser and pulses with nanosecond duration from a Q-switched Nd:YAG laser, both operating at 15 Hz kept at the same average power, were focused in human sound molars for 30 sec. Drilled holes with different morphological characteristics were observed using several laser intensity regimes. Enamel surfaces were examined using a scanning electron microscope (SEM) and their morphological characteristics compared. RESULTS: An interesting contrast between the morphology of the enamel when treated with different level of laser power and pulse duration was observed. Picosecond pulses promote a better-defined material removal with a minimum intermediate region, whereas nanosecond pulses at the equivalent average power level cause a large intermediate modified region between ablated and normal tissue, as well as a complete superficial modification of the existent original structure. CONCLUSION: Our results show an important correlation between the surface morphology and the pulse width of the lasers, suggesting advantages toward the use of ultrashort laser pulses in dentistry.  相似文献   
10.
OBJECTIVE: This study was conducted to analyze microleakage in Class V cavity preparation, using rewetting (or not) just after burr or Er:YAG laser preparation of enamel and dentin walls in permanent teeth. Background Data: Several studies reported microleakage around composite restorations when cavity preparation was done or treated by Er:YAG laser. As the hybridized laser is removed when this laser is used to cut dental hard tissue, there is a need for new materials or techniques to minimize gaps and microleakage. RESULTS: Primer solution showed significant effect in enamel and dentin, at the level of 5%, when Er:YAG laser was used as a cutting tool. Using primer solution after phosphoric acid in preparations with the laser, microleakage was similar in degree to when cavities were prepared with the burr. CONCLUSION: Re-wetting surface just after Er:YAG irradiation and chemical treatment with phosphoric acid using HEMA aqueous solution seems to improve the quality of bioattachment between the adhesive system and enamel/dentin, showing similarities between restoration behaviors independently of the cutting tool, whether burr or laser.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号