首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   16篇
  免费   2篇
口腔科学   16篇
外科学   2篇
  2021年   1篇
  2019年   1篇
  2018年   1篇
  2017年   1篇
  2015年   2篇
  2014年   2篇
  2013年   1篇
  2012年   2篇
  2011年   2篇
  2009年   1篇
  2008年   1篇
  2004年   1篇
  2003年   1篇
  1989年   1篇
排序方式: 共有18条查询结果,搜索用时 20 毫秒
1.
Odontology - Recording fluorescence using flash photography, may help reduce time of capture and apply effectively in clinical practice. To test methods for visualizing composite resins...  相似文献   
2.

Purpose

The aim of this study was to investigate through a questionnaire the knowledge, attitudes and possible differences in the use of flexible RPDPs among dentists in Greece and Croatia.

Material and Methods

A questionnaire of 16 questions was originally created in English, translated into Greek and Croatian language following a two way translation and tested for apprehension, precision, clarity and homogeneity by a number of native English speaking Greek and Croatian dentists. Following the necessary corrections, the questionnaires replicated in two online surveys and their addresses with an informed consent were sent by emails to nearly 4000 dentists in each country to participate. Collected data were analyzed by chi-square tests at a= .05 level of significance.

Results

378 dentists from Greece and 304 from Croatia participated in the study. 137(36.2%) dentists from Greece and 56(18.4%) from Croatia provided flexible RPDPs to their patients. Statistical analysis for all providers indicated no significant difference between genders (P>.05), significant differences between age groups (P<.01), years of practice (P<.05), specialization (P <.001), and instruction on flexible prostheses (P <.001). The analysis between the two countries showed differences for gender and age groups (P<.01) but no differences between experienced, specialized or instructed groups (P >.05).

Conclusion

The survey indicated differences between the two countries in the percentages of dentists using, selecting and providing RPDPs for their patients. Practitioners’ age, years in practice and instruction were associated with the provision of the prostheses, while comfort, esthetics and cost were the reasons for deciding to use the flexible RPDPs.

Conclusion

Although dentists are not educated in their schools about flexible RPDPs, almost a third of them offer this treatment to their patients. Long term success of these devices depends on clinical education, more experience and definitely more research.  相似文献   
3.
4.
5.
6.

Purpose

This study investigates the perceptibility and acceptability thresholds (PT, AT) of observers for L*, a* and b* facial skin differences, very important for the fabrication of a maxillofacial prosthesis.

Methods

One image (10 × 13.3 cm/300 dpi), simulating standard facial skin color, and 27 smaller images (4.9 × 6.0 cm/300 dpi), simulating shades with different RGB values from the standard were made, using Adobe-Photoshop CS3. The RGB values, were based on 9 stepped increases in L*, a* and b*. Images were shown in the middle of a computer screen with the standard image in the background. 90 persons with normal color vision and optical acuity were selected and instructed to evaluate 81 (27 × 3) randomly shown images for a perceptible or an acceptable (48 h later) mismatch, between central and background image. Using best fitting regression curves 50 % PT and 50 % AT for all parameters were estimated along with their 95 %CI.

Results

Observers’ reliability found high (0.807–0.945) while the cubic and exponential were the best fitted curves to the data. Overall 50 % ATs were smaller than 50 % PTs (p < 0.01) and overall ΔL* parameter showed the lowest thresholds (0.119PT/0.864AT), significantly smaller (p < 0.05) than Δa* (0.993PT/2.037AT), Δb* (1.147PT/2.517AT), and ΔEab*(1.497PT/1.808AT). No differences were found between sex or age groups in 50 % ATs for Δa* and Δb* parameters, but 50 % PT for Δa* was smaller in females and in older people with the opposite for Δb*.

Conclusions

Changes in L* were more perceptible and less acceptable than changes in a* and b*. For this reason ΔL* parameter needs attention equally to ΔE*ab when fabricating a facial prosthesis.  相似文献   
7.
The effect of individual shades in shade guides, on the reliability and validity of measurements in a colour matching process is very important. Observer's agreement on shades and sensitivity/specificity of shades, can give us an estimate of shade's effect on observer's reliability and validity. In the present study, a group of 16 students, matched 15 shades of a Kulzer's guide and 10 human incisors to Kulzer's and/or Vita's shade tabs, in 4 different tests. The results showed shades I, B10, C40, A35 and A10 were those with the highest reliability and validity values. In conclusion, a) the matching process with shades of different materials was not accurate enough, b) some shades produce a more reliable and valid match than others and c) teeth are matched with relative difficulty.  相似文献   
8.
The purpose of this in vitro investigation was to compare in primary molars, the validity of DIAGNOdent™ 2095 on occlusal caries diagnosis used either separately or in combination with direct and/or indirect visual examinations, based on histological examination as the reference method. In 24 extracted primary molars, 111 occlusal pits were examined for caries by one trained operator (intra-examiner reliability k > 0.80), using the following examination methods: direct visual (DV), indirect visual (IDV), radiographic (XR), and fluorescence (DD) with the DIAGNOdent™. The extent of caries was then determined histologically. Sensitivity, specificity, accuracy, and the area under the ROC curve (AUC) were calculated for each method separately as well as for the combination of DD with DV and/or IDV. The DD accuracy was found both for lesions into enamel and into dentin to be 0.70 while the accuracy of the DD combination with DV and IDV was found to be 0.89. The DD AUC for lesions into enamel and into dentin, 0.68, were not statistically significant different from the other methods (p > 0.5), however the AUC of the combination of DD with DV and IDV, found to be 0.82, was higher than all the other methods, and this was statistically significant for enamel lesions. The validity of DIAGNOdent™ for occlusal caries diagnosis in primary molars was much higher when the DD was used in combination with direct and indirect visual examination, than when used by itself.  相似文献   
9.
Coronal fractures of posterior teeth are not rare in clinical practice. Most of the time they constitute a restorational problem for the clinician, since they usually end below the free gingival crest. Two hundred coronal fractures of posterior teeth were examined in this study, with respect to several factors. Some of the factors were the sex and age of the patient, type and location of the tooth, and vitality of the pulp. The results showed that frequency of fractures is not influenced by the sex or age of the patient, the type or location of the tooth, or the vitality of the pulp. Factors that significantly affect the appearance of a fracture include caries, restored surfaces, and tooth morphology. Lingual cusps fracture more often than buccal cusps, fractures ended more frequently above or at the gingival crest in teeth with vital pulps, and in nonvital teeth fractures ended more frequently below the crest. Conservative cavity designs for tooth restorations and conservative access to the root canals for endodontic treatment will decrease the frequency of tooth or restoration fracture.  相似文献   
10.
The purpose of this study was to investigate the effect of four commercially available denture adhesives on the incisal and premolar dislodgement forces of maxillary complete dentures by using an electronic and disposable gnathodynamometer and compare the measured incisal forces for differences. This study was conducted with 12 complete maxillary denture wearers. Four commercially available denture adhesives Super Corega®, Corega Ultra®, Super Corega Powder® and Fittydent Cationic® were investigated. Testing protocol and sequence included baseline measurements without adhesives (control) for previous and new dentures and then replications of measurements with the four adhesives. Maximum dislodgement forces were recorded in two sites between central incisors and the left 2nd premolars by using an electronic and disposable gnathodynamometer. To estimate the effect of the different adhesives on the dislodgement forces, data were analyzed by a 2- and 3-way ANOVA, while for estimating the agreement of the two devices a Bland–Altman and Mountain plots were used. ANOVAs indicated significant differences between adhesives (p < 0.05), denture types (p < 0.05) and biting sites (p < 0.05) with both devices. Bland–Altman plot and Mountain plots indicated a poor agreement of the two devices. It was concluded that denture adhesives increase the denture dislodgement forces, but with differences among them. The two devices do not highly agree with each other, but each one alone is useful in estimating dislodgement forces in clinical practice and research.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号