首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   37篇
  免费   1篇
基础医学   1篇
口腔科学   32篇
内科学   5篇
  2022年   1篇
  2021年   7篇
  2020年   2篇
  2019年   3篇
  2018年   2篇
  2017年   1篇
  2016年   1篇
  2015年   1篇
  2013年   1篇
  2012年   2篇
  2008年   5篇
  2007年   7篇
  2006年   5篇
排序方式: 共有38条查询结果,搜索用时 0 毫秒
1.
Odontology - The aim was to explore the fracture-behavior, survival and marginal-microgaps within the root-canal of immature anterior teeth restored with different fiber-reinforced post-core...  相似文献   
2.
Missing a canine is of serious concern in social life of a patient in most of societies. While conventional fixed partial dentures and implant-supported restorations may often be the treatment of choice, fiber-reinforced composite (FRC) resins offer a conservative, fast and cost-effective alternative for single and multiple teeth replacement. This clinical report presents two cases where FRC technology was successfully used to restore canine edentulous area in terms of esthetic-cosmetic values and functionality.  相似文献   
3.
Odontology - This study aimed to evaluate certain physical properties including surface wear of a new experimental short fiber-reinforced flowable resin composite (SFRC) in comparison with...  相似文献   
4.
Clinical Oral Investigations - The aim of this in vitro study was to investigate the fatigue survival and fracture behavior of endodontically treated (ET) premolars restored with different types of...  相似文献   
5.
A newly‐recommended method for restoring large cavities is the biomimetic approach of using short fiber‐reinforced composite (SFRC) as dentine‐replacing material. The aim of the current review was to present an overview of SFRC and to give the clinician a detailed understanding of this new material and treatment strategy based on available‐literature review. A thorough literature search was done up to December 2017. The range of relevant publications was surveyed using PubMed and Google Scholar. From the search results, articles related to our search terms were only considered. The search terms used were “short fiber‐reinforced composite”, “everX posterior”, and “fiber‐reinforced composite restorations”. Of the assessed articles selected (N = 70), most were laboratory‐based research with various test specimen designs prepared according to the ISO standard or with extracted teeth; only four articles were clinical reports. A common finding was that by combining the SFRC as a bulk base with conventional composite, the load‐bearing capacity and failure mode of the material combination were improved, as compared to plain conventional composite restoration. In the reviewed studies, the biomimetic restoration technique of using SFRC showed promising characteristics, and therefore, might be recommended as an alternative treatment option for large cavities.  相似文献   
6.
The goal of current research was to investigate the influence of adding low shrinkage “Phene” like comonomers hexaethylene glycol bis(carbamate-isoproply-α-methylstyrene) (HE-Phene) and triethylene glycol bis(carbamate-isoproply-α-methylstyrene) (TE-Phene) on the surface and color characteristics of composite resin. A range of weight fractions (0, 10, 20, 30, 40 wt.%) of HE/TE-Phene monomers were mixed with bisphenol A glycidyl methacrylate (GMA)/triethylene glycol dimethacrylate (TEGDMA) monomer. Experimental composite resins were made by mixing 71 wt.% of silica fillers to 29 wt.% of the resin matrix. A Vickers indenter and glossmeter were used for testing surface hardness (SH) and gloss (SG) at 60°. A chewing-simulator was used to evaluate the surface wear after 15,000 cycles. Color change (∆E) and translucency parameter (TP) were measured using a spectrophotometer. Data showed that HE/TE-Phene monomer had no negative impact (p > 0.05) on surface gloss, wear, color change and translucency of experimental composite resins. Surface hardness was in a reducing direction with the increas in HE/TE-Phene weight fraction (p < 0.05). The study results suggested that incorporating HE/TE-Phene monomers up to 30 wt.% with Bis-GMA/TEGDMA resin did not negatively influence the surface integrity of composite resins except for SH.  相似文献   
7.
PURPOSE: The aim of this study was to determine the static load-bearing capacity of fractured incisors restored with the conventional adhesive-composite technique or by using fiber-reinforced composites (FRC). MATERIALS AND METHODS: Twelve extracted sound maxillary incisors per group were prepared by cutting the incisal (one-third) part of the crown horizontally. Restorations were made using three techniques. Group A (control group) was restored by reattaching the original incisal edge to the tooth. Group B was restored using particulate filler composite (PFC). Group C was restored with PFC and FRC by adding a thin layer of FRC on the palatal surface of tooth. The bonding system used was the conventional etch system with primer and adhesive. All restored teeth were stored in water at room temperature for 24 h before they were statically loaded until fracture in a universal testing machine. Data were analyzed using ANOVA (p = 0.05). Failure modes were visually examined. RESULTS: Group A (reattaching fractured incisal edge) revealed the lowest load-bearing values, whereas preparation of the new incisal part with PFC revealed 148% higher load-bearing values compared to Group A. Group C (teeth restored with FRC) revealed a 254% higher load-bearing capacity than the control group. ANOVA revealed that the restoration technique significantly affected load-bearing capacity (p < 0.001). The failure mode in Groups A and B was debonding of the restoration from the adhesive interface, while in group C, 50% of the teeth fractured below the cementoenamel junction. CONCLUSION: These results suggest that an incisally fractured tooth restored with a combination of PFC and FRC provide the highest load-bearing capacity.  相似文献   
8.
The preset shape and diameter of a prefabricated FRC post rarely follows the anatomy of the root canal. To solve this problem, a new hollow sleeve composite (HSC) system for post-core construction was developed and characterized. A woven fiber was impregnated with two types of resins: Bis-GMA or PMMA, and rolled into cylinders with outer diameter of 2 mm and two different inner diameters, namely 1.2 or 1.5 mm. The commercial i-TFC system was used as a control. Dual-cure resin composite was injected into these sleeves. Additionally, conventional solid fiber post was used as the inner part of the sleeve. The three-point bending test was used to measure the mechanical properties of the specimens and the fracture surface was examined using an electron microscope (SEM). The HSC (1.5 mm, Bis-GMA) revealed a statistically similar flexural modulus but higher flexural strength (437 MPa) compared to i-TFC (239 MPa; ANOVA, p < 0.05). When a fiber post was added inside, all values had a tendency to increase. After hydrothermal accelerated aging, the majority of specimens showed a significant (p < 0.05) decrease in flexural strength and modulus. SEM fracture analysis confirmed that the delamination occurred at the interface between the outer and inner materials. The HSC system provided flexibility but still high mechanical values compared to the commercial system. Thus, this system might offer an alternative practical option for direct post-core construction.  相似文献   
9.
OBJECTIVES: The purpose of this study was to investigate the reinforcing effect of short E-glass fiber fillers on some mechanical properties of dental composite resin with interpenetrating polymer network (IPN)-polymer matrix. MATERIALS AND METHODS: Experimental composite resin was prepared by mixing short fibers (3mm in length) with a fraction of 22.5 wt% and IPN-resin 22.5 wt% with silane treated silica filler 55 wt% using high speed mixing machine. Test specimens (2 mm x 2 mm x 25 mm) and (9.5 mm x 5.5 mm x 3 mm) were made from the experimental composite (FC) and conventional particulate composite resin (control, Z250, 3M-ESPE). The test specimens (n=6) were either dry stored or water stored (37 degrees C for 30 days) before the mechanical tests. Three-point bending test was carried out according to ISO 10477 and compression loading test was carried out using a steel ball (?3.0mm) with speed of 1.0mm/min until fracture. Degree of monomer conversion (DC%) of both composites was determined by FTIR spectrometry. Water sorption and solubility of specimens were also measured. Scanning electron microscopy was used to evaluate the microstructure of the composite. RESULTS: ANOVA revealed that experimental fiber composite had statistically significantly higher mechanical performance of flexural strength (210 MPa) and compressive load-bearing capacity (1881 N) (p < 0.05) than control composite (111 MPa, 1031 N). Degree of conversion of the FC (59%) and conventional composite (57%) was at the same range. SIGNIFICANCE: The use of short fiber fillers with IPN-polymer matrix yielded improved mechanical performance compared to conventional restorative composite.  相似文献   
10.
OBJECTIVES: Longevity of particulate filler resin (PFR) is controversial for large restorations with high occlusal-stresses. The aim of this study was to reinforce PFR with fiber reinforced composite (FRC) and to evaluate the effect of thickness of FRC substructure and thickness of overlaying PFR, on the static load-bearing capacity of the material combination. METHODS: A total of 336 test specimens having a FRC substructure (short random or continuous bidirectional fibre orientation) and layer of restorative PFR were prepared for this study. In Group A, the specimens contained short random oriented fibres (length: 2-3mm) and in Group B, there were continuous bidirectionally oriented fibres. The specimens (n = 12/group) were polymerized with a hand light-curing unit and were either dry-stored or thermocycled before they were statically loaded with a steel ball until fracture, using a universal testing machine. RESULTS: Increase the volume fraction of the short random FRC versus the fraction of PFR, the load-bearing capacity of the specimen increased (p < 0.001). Short random FRC revealed significantly different behavior than the bidirectionally oriented FRC (p < 0.001). By combining the FRC layer of 0.5mm in thickness with a layer of 2.5mm of PFR gave load values of 1462N and 1196N, which were considerably higher than values for plain PFR of 3mm in thickness (782N and 729N). CONCLUSION: The results suggest that by adding a FRC substructure under the PFR, the load-bearing capacity of the material combination was increased.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号