Background: Neuraxial blockade is used as primary anesthetic technique in one third of surgical procedures. The authors tested whether bisoprolol would protect patients at risk for cardiovascular complications undergoing surgery with spinal block.
Methods: The authors performed a double-blinded, placebo-controlled, multicenter trial to compare the effect of bisoprolol with that of placebo on 1-yr composite outcome including cardiovascular mortality, nonfatal myocardial infarction, unstable angina, congestive heart failure, and cerebrovascular insult. Bisoprolol was given orally before and after surgery for a maximum of 10 days. Adrenergic receptor polymorphisms and safety outcome measures of bisoprolol therapy were also determined.
Results: A total of 224 patients were enrolled. Spinal block could not be established in 5 patients. One hundred ten patients were assigned to the bisoprolol group, and 109 patients were assigned to the placebo group. The mean duration of treatment was 4.9 days in the bisoprolol group and 5.1 days in the placebo group. Bisoprolol therapy reduced mean heart rate by 10 beats/min. The primary outcome was identical between treatment groups and occurred in 25 patients (22.7%) in the bisoprolol group and 24 patients (22.0%) in the placebo group during the 1-yr follow-up (hazard ratio, 0.97; 95% confidence interval, 0.55-1.69; P = 0.90). However, carriers of at least one Gly allele of the [beta]1-adrenergic receptor polymorphism Arg389Gly showed a higher number of adverse events than Arg homozygous (32.4% vs. 18.7%; hazard ratio, 1.87; 95% confidence interval, 1.04-3.35; P = 0.04). 相似文献
FM sonography - a signal-processing technique that uses frequency and phase information as well as amplitude data - shows promise in evaluation of patients with diffuse liver disease. In a prospective blinded review of 37 patients with biopsy-proved liver disease and 42 healthy volunteers, FM sonography was clearly superior to traditional amplitude-based (AM) sonography in distinguishing healthy from diseased subjects. Statistically significant differences were seen in accuracy (FM, 98.7%; AM, 84.8%), sensitivity (FM, 97.3%; AM, 70.3%), and negative predictive value (FM, 97.7%; AM, 78.8%). Our data also suggest that current FM sonographic techniques cannot differentiate among histologic findings associated with different hepatic parenchymal abnormalities. It is unclear, therefore, whether FM imaging can reduce the numbers of patients who require biopsy for diagnosis or the frequency of biopsy procedures in patients with known disease. 相似文献
Prior studies have shown that pneumothorax is one of the more difficult entities to diagnose with digitized radiography. This study was designed to test whether increasing resolution from 1.25 to 2.5 line pairs per millimeter (lp/mm) and image processing (edge enhancement from unsharp masking) would increase accuracy and confidence in the diagnosis of pneumothorax, as well as normal cases and other forms of lung disease. Conventional radiographs were digitized with use of a laser reader and then reformatted as film hard copy. Eleven observers read 35 cases reformatted in three different ways (1.25 lp/mm, 2.5 lp/mm, 1.25 lp/mm unsharp mask). The images with finer resolution (2.5 lp/mm) and unsharp mask images were superior to those with coarser resolution (1.25 lp/mm) for the diagnosis of pneumothorax. There was no difference in diagnostic accuracy for normal patients. For abnormalities other than pneumothorax, the unsharp mask images were significantly worse. Confidence in the diagnosis of pneumothorax and other abnormalities was highest with the finest resolution (2.5 lp/mm). 相似文献
Abstract Traumatic dislocation of the trapeziometacarpal joint is rare. A stable reduction should be accomplished as soon as possible,
usually with K-wiring. In this case of persistent instability a semi-constrained prosthesis was applied successfully. 相似文献
Accuracy and performance of the only currently available intra-arterial
blood-gas monitoring system (Paratrend 7, PT7) were assessed in 23 patients
during thoracoscopic surgery using one-lung ventilation. Over a wide range
of values for arterial PO2 (6.1-61.1 kPa), PCO2 (4.1-9.5 kPa) and pH
(7.19-7.50), 138 arterial blood-gas values obtained by PT7 were compared
with corresponding in vitro laboratory blood-gas measurements. We found
good clinical performance with the PT7 and good agreement between PT7
values and in vitro measurements for arterial PO2 (bias (1.96 SD) = 0.38
(9.52) kPa), PCO2 (0.31 (0.76) kPa) and pH (- 0.017 (0.065)). Also, the
bias for sequential changes between two, consecutive times was not
significantly different from the ideal value of 0. We conclude that the PT7
is helpful in monitoring patients during thoracoscopy.
相似文献
Since there are conflicting reports in the literature on a possible relationship between the K1 capsular polysaccharide (CP) content of Escherichia coli and its susceptibility to killing, we reexamined this issue in a strain that had a smooth lipopolysaccharide (LPS) phenotype (E. coli O18:K1:H7 Bort) and in a strain with a deep rough LPS phenotype (E412, spontaneously agglutinable: K1:H-). When cell-associated K1 capsular content was greater than 90 micrograms of K1 polysaccharide per 10(10) CFU, neither strain was lysed by 20% normal human serum. In contrast, at equivalent but lower levels of K1 CP content, E412 but not strain Bort was lysed by normal human serum. Thus, LPS phenotype is an additional surface determinant that affects bacterial susceptibility to killing. Organisms obtained from very early log phase, when cell-associated K1 CP is greatest, were significantly more virulent for mice than were bacteria harvested in stationary phase, when cell-associated K1 polysaccharide is lowest. We conclude that (i) there is a threshold level of K1 CP needed to confer protection from lysis by serum, and this is usually exceeded under standard growth conditions; (ii) at a given level of K1 CP the LPS phenotype is an important determinant of bacterial killing; and (iii) the loss of capsule at low pH may be an additional mechanism by which hosts defend against invasive infection by K1-encapsulated E. coli. 相似文献
The reactions of serogroup A strains of Neisseria meningitidis with one monoclonal antibody specific for serotype 21 and three different monoclonal antibodies specific for serotype 4 were compared with those of serogroup B strains previously assigned to serotype 4. Antibody binding was studied by enzyme-linked immunosorbent assay (ELISA), dot blotting, and immunoblotting. Characterization of the isolates by the electrophoretic mobilities of 14 metabolic enzymes showed 50 multilocus enzyme genotypes. All except two genotypes fell into three distinct clusters: I, IIa and IIb. The enzyme genotypes of serogroup B strains were mainly in cluster I, and 88% of the serogroup A strains had genotypes in clusters IIa and IIb. Serogroup B strains generally reacted with all three serotype 4 monoclonal antibodies in ELISA and dot blotting but with only two in immunoblots. Serogroup A strains showed two different reactions in the blotting methods: either binding of the serotype 21 antibody only or binding of this and two of the three serotype 4 monoclonal antibodies. Strains of the first pattern were in clusters I and IIa, whereas all but two strains in cluster IIb were of the second pattern. In ELISA, an additional reaction of two of the serotype 4 monoclonal antibodies with serogroup A isolates was observed. The different binding of these two monoclonal antibodies in ELISA and the blotting methods appeared to result from heat inactivation of the meningococcal cells and use of detergent-containing reagents in ELISA. The results show that the serotype of serogroup A strains is distinct from serotype 4 of serogroup B strains. 相似文献