首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   1篇
基础医学   4篇
临床医学   1篇
皮肤病学   1篇
预防医学   3篇
  2012年   1篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2007年   1篇
  2006年   1篇
  2005年   2篇
  1997年   1篇
排序方式: 共有9条查询结果,搜索用时 15 毫秒
1
1.
Ensuring completion of tuberculosis (TB) treatment remains a major public health problem. In HIV-infected patients, TB is the most common severe opportunistic infection. Few studies have evaluated risk factors for TB treatment default in HIV-infected patients. We conducted a prospective, observational study of HIV-infected TB patients in Thailand. Patients underwent standardised evaluations at the beginning of TB treatment, at the end of the intensive phase and at the end of TB treatment. TB treatment outcomes were assessed according to WHO guidelines. The analysis was limited to patients who defaulted or who had treatment success. Of the 554 patients analysed, 61 (11%) defaulted. In multivariate analysis, factors associated with TB treatment default included incarceration history [adjusted odds ratio (AOR) 2.0, 95% CI 1.1-3.7), smoking (AOR 2.3, 95% CI 1.3-4.1) and having a symptom complaint score >15 (AOR 3.4, 95% CI 1.4-8.0); one marker of wealth, namely owning a refrigerator, was protective (AOR 0.4, 95% CI 0.2-0.8). Default during TB treatment was a significant problem in HIV-infected patients. Reducing default may require enhancing services for patients with a history of incarceration or smoking and designing patient-centred systems to address poverty and patient wellness.  相似文献   
2.
OBJECTIVES: Although cervical cancer is an AIDS-defining illness, few HIV-infected women are routinely screened for cervical cancer in Thailand. We screened HIV-infected women for cervical cancer as a component of HIV care and assessed high-risk human papillomavirus (HPV) and cervical cancer prevalence. METHODS: From July 2003 through February 2004, HIV-infected women attending either an infectious disease clinic or a sexually transmitted infection (STI) clinic in Bangkok were tested for high-risk HPV types by Hybrid Capture 2 and screened for cervical cancer by Pap test; those with abnormal cervical cytology were referred for diagnosis and treatment. RESULTS: Two hundred ten HIV-infected women at an infectious disease clinic (n = 150) and an STI clinic (n = 60) received cervical cancer screening. The high-risk HPV prevalence was 38.6% and the prevalence of abnormal cervical cytology was 20.4%. Abnormal cervical cytology and high-risk HPV detection were associated (P < 0.001). We received pathology reports for 23 (53.5%) of 43 women, including all those with a Pap test showing high-grade squamous intraepithelial lesions; the cervical cancer prevalence was 1.9% (4 of 210; 95% confidence interval, 0.5-4.8%). CONCLUSION: The estimated prevalence of high-risk HPV and cervical cancer among HIV-infected women in Thailand was high. This emphasizes the need to integrate cervical cancer screening into HIV care.  相似文献   
3.
Use of the standard dual-platform flow cytometric method for determination of CD4+ T-lymphocyte counts, which needs both a flow cytometer (FCM) and hematological analyzer, would inevitably lead to increased variability. The development of new single-platform (SP) FCMs that provide direct CD4+ T-lymphocyte counts for improved assay precision and accuracy have recently attracted attention. This study evaluated one of those systems, CyFlowgreen (Partec), a single-parameter SP volumetric FCM. The performance of CyFlowgreen was compared with those of two reference standard SP microbead-based technologies of the three-color TruCOUNT tube with the FACScan FCM and a two-color FACSCount system (Becton Dickinson Biosciences). Absolute CD4+ and CD8+ T-lymphocyte counts in 200 human immunodeficiency virus type 1-seropositive blood specimens were determined. Statistical analysis for correlation and agreement were performed. A high correlation of absolute CD4 counts was shown when those obtained with CyFlowgreen were compared with those obtained with the bead-based three-color TruCOUNT system (R2 = 0.96; mean bias, −69.1 cells/μl; 95% confidence interval [CI], −225.7 to +87.5 cells/μl) and the FACSCount system (R2 = 0.97; mean bias, −40.0 cells/μl; 95% CI, −165.1 to +85.1 cells/μl). The correlation of the CD4+ T-lymphocyte counts obtained by the two bead-based systems was high (R2 = 0.98). Interestingly, CyFlowgreen yielded CD4+ T-lymphocyte counts that were 21.8 and 7.2 cells/μl lower than those obtained with the TruCOUNT and the FACSCount systems, respectively, when CD4+ T-lymphocyte counts were <250 CD4+ T-lymphocyte counts/μl range or 17.3 and 5.8 cells/μl less, respectively, when CD4+ T-lymphocyte counts were <200 cells/μl. The single-parameter CyFlowgreenvolumetric technology performed well in comparison with the performance of the standard SP bead-based FCM system. However, a multicenter comparative study is needed before this FCM machine is implemented in resource-limited settings.  相似文献   
4.
Controlled trials have demonstrated that liquid media culture (LMC) is superior to solid media culture for diagnosis of Mycobacterium tuberculosis (MTB), but there is limited evidence about its performance in resource-limited settings. We evaluated the performance of LMC in a demonstration project in Bangkok, Thailand. Sputum specimens from persons with suspected or clinically diagnosed tuberculosis were inoculated in parallel on solid (Lowenstein-Jensen [LJ]) and liquid (mycobacterial growth indicator tube [MGIT 960]) media. Biochemical tests identified isolates as MTB or nontuberculosis mycobacteria (NTM). Of 2566 specimens received from October 2004 to September 2006, 1355 (53%) were culture positive by MGIT compared with 1013 (39%) by LJ. Median time to growth for MGIT was significantly less than LJ: 11 versus 27 days. Of 1417 isolates detected by at least 1 media, 1255 (86%) were identified as MTB and 162 (11%) NTM. MGIT improved speed and sensitivity of MTB isolation and drug susceptibility testing, regardless of HIV status.  相似文献   
5.
6.
OBJECTIVES: As Thailand scales up its antiretroviral treatment program, the role of sexually transmitted infection (STI) services to prevent HIV transmission has not been addressed. We provided STI services for HIV-infected women as a component of HIV care and assessed STI prevalence and risk behaviors. METHODS: HIV-infected women attending an infectious disease clinic and an STI clinic in Bangkok were screened for the presence of genital ulcers by visual inspection, for gonorrhea and chlamydial infection by polymerase chain reaction, for trichomoniasis by wet mount, and for syphilis by serology. Women were asked about sexual risk behavior and use of antiretroviral treatment. Risk-reduction counseling, condoms, and STI treatment were provided. RESULTS: Two-hundred ten HIV-infected women at an infectious disease clinic (n = 150) and an STI clinic (n = 60) received STI services from July 2003 through February 2004. The prevalence for any STI was 8.0% at the infectious disease clinic and 30.0% at the STI clinic (P < 0.01). Of the 116 (55.2%) sexually active women, 42 (36.2%) reported sex without a condom during the last 3 months. Women receiving antiretroviral treatment reported condom use during last sex more often compared with those not receiving antiretroviral treatment (82.2% vs. 58.8%; P = 0.03). CONCLUSION: STIs and sexual risk behavior were common among these HIV-infected women, and STI services for HIV-infected persons have been expanded to more clinics in Thailand. Further analysis of HIV transmission risk is necessary for developing a national strategy for prevention of HIV transmission among HIV-infected persons.  相似文献   
7.
The FACSCount flow cytometer absolute CD3+, CD3+ CD4+, and CD3+ CD8+ cell counts measured at a field site hospital laboratory in Thailand were compared to FACScan absolute counts obtained at a nearby research laboratory. Correlation coefficients for 208 samples were > or = 0.95. The FACSCount was accurate, and it was easier and less expensive to operate than the FACScan. Additionally, the FACScan-generated lymphocyte percentage value was accurate for use with the FACScan SimulSET software.  相似文献   
8.
Use of the standard dual-platform flow cytometric method for determination of CD4(+) T-lymphocyte counts, which needs both a flow cytometer (FCM) and hematological analyzer, would inevitably lead to increased variability. The development of new single-platform (SP) FCMs that provide direct CD4(+) T-lymphocyte counts for improved assay precision and accuracy have recently attracted attention. This study evaluated one of those systems, CyFlow(green) (Partec), a single-parameter SP volumetric FCM. The performance of CyFlow(green) was compared with those of two reference standard SP microbead-based technologies of the three-color TruCOUNT tube with the FACScan FCM and a two-color FACSCount system (Becton Dickinson Biosciences). Absolute CD4(+) and CD8(+) T-lymphocyte counts in 200 human immunodeficiency virus type 1-seropositive blood specimens were determined. Statistical analysis for correlation and agreement were performed. A high correlation of absolute CD4 counts was shown when those obtained with CyFlow(green) were compared with those obtained with the bead-based three-color TruCOUNT system (R(2)=0.96; mean bias, -69.1 cells/microl; 95% confidence interval [CI], -225.7 to+87.5 cells/microl) and the FACSCount system (R(2)=0.97; mean bias, -40.0 cells/microl; 95% CI, -165.1 to+85.1 cells/microl). The correlation of the CD4(+) T-lymphocyte counts obtained by the two bead-based systems was high (R(2)=0.98). Interestingly, CyFlow(green) yielded CD4(+) T-lymphocyte counts that were 21.8 and 7.2 cells/microl lower than those obtained with the TruCOUNT and the FACSCount systems, respectively, when CD4(+) T-lymphocyte counts were <250 CD4(+) T-lymphocyte counts/microl range or 17.3 and 5.8 cells/microl less, respectively, when CD4(+) T-lymphocyte counts were <200 cells/microl. The single-parameter CyFlow(green) volumetric technology performed well in comparison with the performance of the standard SP bead-based FCM system. However, a multicenter comparative study is needed before this FCM machine is implemented in resource-limited settings.  相似文献   
9.
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号