首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   93篇
  免费   5篇
耳鼻咽喉   1篇
儿科学   1篇
基础医学   4篇
临床医学   4篇
内科学   2篇
皮肤病学   1篇
神经病学   1篇
特种医学   79篇
外科学   4篇
预防医学   1篇
  2022年   1篇
  2021年   7篇
  2020年   1篇
  2019年   2篇
  2018年   6篇
  2017年   3篇
  2016年   6篇
  2015年   1篇
  2014年   5篇
  2013年   7篇
  2012年   7篇
  2011年   12篇
  2010年   3篇
  2009年   1篇
  2008年   5篇
  2007年   8篇
  2006年   7篇
  2005年   2篇
  2004年   2篇
  2003年   5篇
  2002年   4篇
  2001年   1篇
  1997年   2篇
排序方式: 共有98条查询结果,搜索用时 390 毫秒
1.
The purpose of this work was to compare direct and indirect detectors in terms of their system linearity, presampled modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ), and power spectrum. Measurements were made on two flat-panel detectors, GE Revolution XR/d (indirect) and Shimadzu Safire (direct) radiographic techniques. The system linearity of the systems was measured using a time-scale method. The MTF of the systems was measured using an edge method. The WS of the systems was determined for a variable range of exposure levels by two-dimensional Fourier analysis. The NEQ was assessed from the measured MTF, WS, and estimated ideal signal-to-noise ratios. Power spectrum analyzed the chest phantom within artificial lesions. System linearity was excellent for the direct systems. For the direct system, the MTF was found to be significantly higher than that for the indirect systems. For the direct system, the WS was relatively uniform across all frequencies. In comparison, the indirect system exhibited a drop in the WS at high frequencies. At lower frequencies, the NEQ for the indirect system was noticeably higher than for the direct system. Power spectrum for the direct system was relatively flat and similar to that for white noise. The indirect system exhibited significant reduction at high spatial frequencies. In general, the direct systems exhibit improved image quality over indirect systems at comparable exposure dose.  相似文献   
2.
3.
ObjectiveIn cases of head and neck cancer treated with intra-arterial chemotherapy, no objective indices are available for determining the distribution of anticancer drugs administered to multiple arteries. To establish such indices, noninvasive measurements of drug concentrations are required in the arterial perfusion area of each artery. In MRI, changes in 1/T1 (Δ1/T1) are correlated with the contrast agent concentration. We focused on these properties and investigated whether it is possible to estimate anticancer drug concentrations within tissue based on Δ1/T1.MethodsWe employed the fast spin echo (FSE) sequence to determine optimum imaging parameters using a phantom. Subsequently, contrast agent was administered via the lingual and external carotid arteries for seven cases of tongue cancer. Δ1/T1 were then measured in tumor and nontumor tissues. The results of this study were compared with those of a previous study in which intratumor concentrations of anticancer agent were measured in excised specimens.ResultsThe optimum imaging parameters for the FSE was two repetition times (TR, 500 and 1000 ms). When compared with the external carotid artery administration, the lingual artery administration of contrast agent resulted in significantly higher Δ1/T1 in both tumor and nontumor tissues (2.13 and 2.62 times, respectively). The multiplying factor for the nontumor tissue and high homogeneity of the contrast agent concentration were reasonably consistent with the results of the previous study.ConclusionThis method can be applied to estimating intratissue concentrations of intra-arterially administered anticancer drugs, thus possibly providing useful information in determining the distribution of anticancer drugs.  相似文献   
4.
We developed an easy method of measuring the presampling modulation transfer function (MTF) using the square wave chart in digital radiography. In this method, the presampling MTF is measured by Fourier transform of image data of the square wave chart. When Fourier analysis of the sampling data of a square wave is carried out, it is generally difficult to find the starting point and terminal point of the periodic data that should be extracted because of an insufficient number of data. To solve this problem, interpolated data were calculated by using a window function of the frequency domain. The aliasing error was avoided using a characteristic such that the square wave has discrete frequency components. The accuracy of this method was investigated by computer simulation study. Actual measurement of the presampling MTF by this method was also performed with a CR system. These studies indicated the effectiveness of our proposed method in terms of accuracy and ease of use.  相似文献   
5.
The purpose of this study was to find an equation between signal-to-noise ratio (SNR) and repetition time (TR) in order to adjust SNR by changing TR in magnetic resonance imaging (MRI) examinations. Using a phantom for SNR measurement, according to NEMA MS 1-1988, measurement of SNR was performed by spin-echo pulse sequences for various TR values. An equation of SNR and scanning parameters including TR were obtained from these results. In order to determine the range of TR where the images showed contrast suitable for diagnosis, the contrast-to-noise ratio (CNR) was measured for various TR values. CNR measurement was performed by scanning a brain phantom, and CNR was defined as the contrast of white matter and gray matter divided by noise. Scanning of a resolution phantom was carried out with various scanning parameters, and the usefulness of the equation obtained was determined by whether or not pins in the phantom were visible. The reliability of the equation was confirmed from this verification. Results showed that TR can be used for the adjustment of SNR using the equation obtained in this study.  相似文献   
6.

Objective

The aim is to compare and evaluate the agreement of quantification of left ventricular functional parameters obtained by two different methods, 99mTc-tetrofosmin gated myocardial perfusion SPECT (MPS) and cardiac magnetic resonance imaging (CMR).

Methods

Ten healthy male volunteers participated. Gated MPS data were acquired using 32 frames, which were also combined into 16- and 8-frame data set for the investigation. Gated CMR data were acquired using 8, 16 and 32-frame for the different sets. All examinations were conducted in resting and at exercise conditions. Quantitative measurements of end-diastolic volume (EDV), end-systolic volume (ESV), left ventricular ejection fraction (LVEF), peak ejection rate (PER), peak filling rate (PFR) and time to peak filling (TTPF) were done for each study, respectively. Finally, we evaluated the concordance of parameters between gated MPS and gated CMR by % difference and Bland?CAltman plot analysis.

Results

LVEF showed favorable concordance in both rest and exercise conditions (% differences were around 10%). PER, PFR and TTPF also showed good concordances in rest conditions, under 32-frame gated collections particularly (% differences were around 10%). In exercise conditions, although the concordances were relatively good, certain variances were noted (% differences were around 20?C25%). Regarding left ventricular volumes, the concordance were worse in both conditions (% differences were around 30?C40%).

Conclusions

In quantifying of left ventricular function parameter, gated CMR provides similar quantitative values comparing with gated MPS except for ventricular volumes in rest conditions. In contrast, there were certain variations except for LVEF in exercised examinations. When we follow patients by the same cardiac parameters with CMR and MPS, using parameters across the two modalities proved to be possible under rest condition. However, it is limited at exercise condition.  相似文献   
7.
Diffusion-weighted imaging (DWI) has been used to characterize not only the brain, but also the breast by implementation of faster imaging techniques and higher magnetic field strengths. However, the optimum b value, which is an important scan parameter for DW images contrast on 3 T breast magnetic resonance imaging (MRI) has not been established. The purpose of this study was to investigate the influence of different b value combinations on the image contrast and apparent diffusion coefficient (ADC) in patients with known invasive carcinoma, ductal carcinoma in situ (DCIS), and normal mammary gland in breast DWI. The analysis procedure consisted of the following methods: 1) T(2) correction of DW images with echo-planar imaging (EPI) T(2)-weighted images; 2) contrast measurement between normal mammary gland and tumor tissues; 3) ADC measurement of normal mammary gland and tumor tissues. In many cases, the highest contrast between normal mammary gland and tumor tissues was obtained using a b value of 1500 s/mm(2). Our results indicated that when only one b value is used, the b value in which signal intensities of normal mammary gland decreases down to noise level, and the contrast between normal mammary gland and tumor tissues is recommended. ADC value decreased with increasing b value. Therefore, when determining the ADC threshold level, it is important to perform the evaluation using ADC values calculated from DW images with the same b value in clinical studies.  相似文献   
8.
Interleukin (IL)-10 is a cytokine that regulates inflammatory responses. We studied the role of IL-10 in the development of tolerance to Dermatophagoides farinae in asthma patients in remission, since asthma improves in most children during adolescence. The spontaneous production of IL-10 by cultured peripheral blood mononuclear cells (PBMC) was higher in patients with active asthma than in normal subjects. IL-10 production decreased when 1 microg/ml D. farinae was added to cultures, but increased again in a dose-dependent manner when higher concentrations of D. farinae were added. In patients with remission of asthma, IL-10 production was lower than in patients with active asthma. However, production of IL-10 showed a reciprocal increase in the presence of 1 microg/ml D. farinae, and decreased again at 10 and 50 microg/ml D. farinae. Such alterations were not observed in normal subjects. Cell lines established from patients asthma in remission showed higher IL-10 production when compared with that by cell lines from normal subjects or patients with active asthma when the cells were stimulated by D. farinae at 1 or 10 microg/ml. Neutralization of IL-10 led to revival of the D. farinae-specific proliferative response of PBMC from patients in remission, which was otherwise decreased. The increase of IL-10 production stimulated by D. farinae was inhibited by addition of an anti-IL-10 antibody. In contrast, antigen-induced interferon (IFN)-gamma production, which was increased by D. farinae stimulation when patients were in remission, did not increase after treatment with anti-IL-10, although spontaneous IFN-gamma production increased to the level seen after D. farinae stimulation. The reduced IL-4 production by cells from patients in remission after stimulation with D. farinae antigen, which was significantly higher in active patients, was not reversed by neutralization of IL-10. The D. farinae-induced IL-10/IL-4 production ratio, but not the IL-10/IL-5 production ratio, may be a significant indicator for evaluation of whether a patient has been in remission. In conclusion, D. farinae-specific anergy of T cells is likely to be induced by increased levels of IL-10 and IFN-gamma that are initially produced by specific T cells after exposure to relevant mite allergen in patients in remission.  相似文献   
9.

Purpose

Although an apparent diffusion coefficient (ADC) value is often used for differential diagnosis of tumours, it varies with scanning parameters. The present study was performed to investigate the influence of imaging parameters, i.e., b value, repetition time (TR) and echo time (TE), on ADC value.

Methods

The phantoms were scanned using diffusion weighted imaging (DWI) with changing b values (b = 0-3000 s/mm2), TR and TE to determine the influence on ADC. Moreover, ADC of the brain in normal volunteers was determined with varying b values (b = 0-1000 s/mm2).

Results

Diffusion decay curves were obtained by biexponential fitting in all phantoms. The points where fast and slow components of the biexponential decay crossed were called turning points. The b values of turning points that crossed from the biexponential curve were different in each phantom. The b values of turning points depended on ADC of fast diffusion component. When ADC is calculated using two b values of front and back for the turning point, the ADC value may be different. Therefore, it was necessary to perform calculations by b value until the turning point to obtain the ADC value of the fast component. In addition, b ≥ 100 was recommended to avoid the influence of perfusion by blood. Furthermore, the choice of long TR and short TE was effective for accurate measurement of ADC.

Conclusion

It is important to determine the turning point for measuring ADC.  相似文献   
10.
We have reported that the apparent diffusion coefficient (ADC) was correlated with bone mineral density, but the relation between the restricted diffusion of the water molecules and the trabecular bone structure was unclear. The purpose of our study is to clarify this relationship using two component analyses with an original phantom. With an increase in the interspace area of the simulated trabecular bone, the ADC of the fast component was increased, and the fraction of the fast component was also increased. On the other hand, with an increase in the interspace area of the simulated trabecular bone, the ADC of the slow component was decreased, and the fraction of the slow component was increased. Moreover, the ADC and fraction of the dry vertebral bone agreed with those of the simulated trabecular bone. This result means that our phantoms can reproduce the actual trabecular bone structure, which induces the restricted diffusion. The diffusion of the water molecules was separated into fast and slow components because of the restricted diffusion of the trabecular bone structure. Our original phantom enables analyzing restricted diffusion, and this analytical method obtains more detailed information on trabecular bone structure.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号