Reikerås O Johansson CB Sundfeldt M 《Journal of long-term effects of medical implants》2006,16(2):157-164
The aim of this study was to investigate whether the coating of titanium (Ti) implants with hydroxyapatite (HA) might create a better fixation when titanium implants are implanted into a gap. In each of 16 rats, the medullary cavity of both femurs was entered by an awl from the trochanteric area. With steel burrs it was successively reamed to a diameter of 1.5 mm. In a random manner the proximal part of the cavity in half of the bones was reamed once again to a diameter of 2.0 mm. Nails with a diameter of 1.5 mm and a length of 34 mm were then inserted into the medullary cavity of these bones with press fit at the distal half and a gap to the bone in the proximal half. In the remaining bones the whole medullary canal was reamed to a diameter of 2.0 mm, and nails with a diameter of 2.0 mm and a length of 34 mm were introduced. In all cases, either a pure Ti nail or a Ti nail entirely plasma sprayed with HA was used in a random manner. The surface roughness of the pure Ti was characterized by Ra 2.6 microm and Rt 22 microm. Ra of HA was 7.5 microm and Rt 52 microm. At sacrifice after 16 weeks, both femurs were dissected free from soft tissues and then immersed in fixative. A specimen slice of about 5 mm in thickness was prepared from the subtrochanteric region with a water-cooled band saw. Sample preparation for undecalcified tissue followed the internal guidelines at the laboratories of the Department of Biomaterials/Handicap Research. Generally, bone contact to the nails with HA coating was more predictable than was bone contact to the Ti nails. But due to rather large variations in bone contact between the samples, statistical analyses revealed non-significant differences between the 4 groups (p = 0.083). There were no significant differences between Ti and HA coated nails of 2.0 mm (p = 0.633), nor between Ti and HA coated nails of 1.5 mm (p = 0.924). The pooled values for the 2.0 mm nails showed significantly higher bone bonding contact than the pooled values of the 1.5 mm nails (p = 0.011). Our results, then, indicate that bone bonding contact to implants with a loose fit insertion is less predictable than in press fit insertion, and HA coating seemed to be more predictable than pure Ti. However, due to large variations between the samples, the differences did not reach significant levels. 相似文献
2.
Mathias Pålsson Jan-Henrik Stjerndahl Gabriel Granåsen Mats Löfgren Karin Sundfeldt 《International urogynecology journal》2017,28(9):1341-1349
Introduction and hypothesis
Hysterectomy is sometimes considered the cause of lower urinary tract symptoms (LUTS). We hypothesized that hysterectomy for abnormal uterine bleeding and/or symptoms of fibroids is more likely to cause LUTS than a hysteroscopic procedure for the same indications.Methods
Two groups of women were compared: one group comprised 3,618 women who had had a hysterectomy due to abnormal uterine bleeding or symptoms of fibroids and the other group comprised 238 women who had had hysteroscopic treatment for the same indications. The main outcome measures were occurrence of LUTS before and 1 year after the surgical intervention. The frequencies of LUTS before and after surgery were compared between the groups. Binary logistic regression was used to model the odds of having postoperative urinary leakage and urgency while controlling for uterine size, surgical procedure and preoperative LUTS.Results
There were no statistically significant differences between women after hysterectomy and after hysteroscopy in the frequencies of LUTS before or after surgery, when uterine size was comparable. However, there was a difference in the rates of de novo urinary incontinence between women with hysterectomy and women with hysteroscopy (7.6%, 95% CI 6.3–9.0, and 3.2%, 95% CI 1.6–6.5, respectively). Of the women with a large uterus, 58.6% (95% CI 51.5–65.5) reported relief of urinary incontinence and 85.5% (95% CI 82.3–88.4) reported relief of urinary urgency postoperatively.Conclusions
Our results suggest that it is important to individualize preoperative information in women prior to hysterectomy since the outcome concerning LUTS depends on preoperative symptoms and uterine size.3.
4.
5.
Partheen K Levan K Osterberg L Claesson I Fallenius G Sundfeldt K Horvath G 《International journal of cancer. Journal international du cancer》2008,123(9):2130-2137
The mortality rate for patients with ovarian carcinomas is high and the available prognostic factors are insufficient. The use of biomarkers may contribute to better prediction and survival for these patients. We aimed to study the gene and protein expressions for 7 potential biomarkers, to determine if it is possible to use them as prognostic factors. Genes selected from our previous microarray analysis (2006), CLU, ITGB3, TACC1, MUC5B, CAPG, PRAME and TROAP, were analyzed in 19 of the tumors with quantitative real-time polymerase chain reaction (QPCR). We found that CLU and ITGB3 were more expressed in tumors from survivors and PRAME and CAPG were more expressed in tumors from deceased patients. None of the other 3 genes were significantly differently expressed. The protein expressions of CLU, ITGB3, PRAME and CAPG were analyzed in 43 of the tumors with western blot for semiquantitative analysis. We established that the mRNA and protein expressions correlated and that all 4 proteins were significantly differently expressed. Further, immunohistochemistry (IHC) was used to localize the expression of the proteins in the tumor samples. According to our results, the 4 biomarkers CLU, ITGB3, PRAME and CAPG may be used as prognostic factors for patients with stage III serous ovarian adenocarcinomas. 相似文献
6.
Lind AK Weijdegård B Dahm-Kähler P Mölne J Sundfeldt K Brännström M 《Acta obstetricia et gynecologica Scandinavica》2006,85(12):1476-1484
BACKGROUND: Remodeling of the collagens around the follicle is a major event in ovulation. The aim of the present study was to investigate the distribution of collagen I, III, and IV in the human ovary. METHODS: Biopsies of the perifollicular stroma were obtained at sterilization during the preovulatory phase (follicle size >14 mm) or at any of three intervals (12-18 h after human chorionic gonadotrophin: early ovulatory phase; >18-24 h: late ovulatory phase; 44-77 h: postovulatory phase) after human chorionic gonadotrophin. Excised dominant follicles and whole ovarian sections were also obtained. Immunohistochemistry using antibodies against collagen I, III, IV, vimentin, and CD 45 was performed. RESULTS AND CONCLUSIONS: Collagens I and III were distributed in concentric layers in the capsular stroma with bundles of collagens connecting these layers to form a mesh. Collagen I was present in larger quantities in the outer layers and collagen III showed the inverse distribution. In the theca, collagen I was present in the externa and collagen III in the entire layer. The staining intensity of collagens I and III in the perifollicular stroma decreased from the preovulatory stage. Collagen IV was present in the basal lamina separating granulosa and theca cells. This study shows that collagen I and III are abundant in and around the ovulating human follicle with typical patterns of distribution. Collagen IV is present in the basal membrane that separates the granulosa from the theca cells. Taking into account the abundance of collagens in the follicular wall and their specific localization, major site-directed degradation of collagens seems to be necessary for follicular rupture to occur. 相似文献
7.
Reikerås O Johansson CB Sundfeldt M 《Journal of long-term effects of medical implants》2004,14(6):443-454
The aim of this study was to investigate the interaction between bone and pure titanium, titanium coated with hydroxyapatite (HA), and titanium coated with carbon in a rat femur model. In 25 rats, the medullary cavity of both femurs was entered by an awl from the trochanteric area. With steel burrs it was successively reamed to a diameter of 2.0 mm. Nails with a diameter of 2.0 mm and with a length of 34 mm were inserted in a random manner; either a pure titanium nail, a titanium nail entirely plasma-sprayed with a 75-100-microm layer of HA or a titanium nail coated with 2-10-microm carbon. The surface roughness of the pure titanium was characterized by Ra 2.6 microm and Rt 22 microm. Ra of HA was 7.5 microm and Rt 52 microm, and of carbon Ra was 0.4 microm and Rt 4.0 microm. Twelve rats were randomized to a follow up of 8 weeks, and the remaining 13 rats were followed for 16 weeks. At sacrifice both femora were dissected free from soft tissues and then immersed in fixative. A specimen slice of about 5 mm thickness was prepared from the subtrochanteric region with a water-cooled band-saw. Sample preparation for un-decalcified tissue followed the internal guidelines at the laboratories of Biomaterials/Handicap Research. At 8 weeks the median bone bonding contact of the implants was 43% (range 0-74) in the titanium group, 39% (0-75) in the HA group, and 3% (0-59) in the carbon group. At 16 weeks the corresponding figures were 58% (0-78) in the titanium group, 51% (15-75) in the HA group, and 8% (0-79) in the carbon group. In conclusion, we found great variability in bone bonding contact. In general, carbon-coated nails had reduced bone bonding contact both at 8 and at 16 weeks as compared to pure titanium or titanium coated with hydroxyapatite. 相似文献
8.
9.
Sundfeldt M Widmark M Johansson CB Campbell P Carlsson LV 《Acta orthopaedica Scandinavica》2002,73(4):416-424
In a rabbit model of a weight bearing, articulating prosthetic joint we repeatedly injected submicron particles of Ultra-High-Molecular-Weight-Polyethylene (UHMWPE) produced in a hip simulator. The contralateral knee with the same prosthesis was injected with carrier (NaCl) without UHMWPE. Histomorphometrical studies on undecalcified cut and ground sections at 26 and 42 weeks involved quantifications of the entire bone to metal contact and the bone area around each implant. We found no statistically significant differences between test and control groups, and the UHMWPE debris did not induce any significant osteolysis, indicating that an osseointegrated implant with a sealed interface may not be affected by UHMWPE debris or progress to aseptic loosening. 相似文献
10.
Sundfeldt M Johansson CB Regnér L Albrektsson T Carlsson LV 《Journal of long-term effects of medical implants》2003,13(4):341-354
Aseptic loosening of cemented knee arthroplasties has encouraged development of uncemented fixation. The Miller-Galante I (MG I) prosthesis was designed to achieve permanent stability through ingrowth into a titanium fiber mesh. Thirty-five knees in 30 patients with MG I knee replacements have been followed clinically and radiologically with a mean follow-up of 12 years. Twenty knees were revised with a mean follow-up of 5 years. Patellofemoral problems, especially avulsion of the polyethylene from the metal-backed patella and in some cases severe metallosis, have been the main reason for revision. Metal-backed patellar component should be avoided. In addition, instability has been a problem. However, the fixation of the components has been excellent, with a high degree of osseous ingrowth displayed at histological analysis of retrieved components. The clinical and radiological results after revision are in most cases good, despite the femoral component having been left in situ. 相似文献