排序方式: 共有40条查询结果,搜索用时 15 毫秒
1.
N. Govindarajan S. Meiyappan O. Prakash 《Journal of clinical monitoring and computing》1993,9(3):141-148
We have applied advanced real-time techniques in softwave, that are intensively used in critical areas like space research and defence applications, to realise an Integrated Real-Time Respiratory Monitoring System at the Thorax Anesthesiology, Academic Hospital Rotterdam. The system is called the SERVO WINDOW —a window to the servo ventilator. The heart of the system is a real-time kernel that uses preemptive scheduling to achieve multitasking on a IBMPC compatible hardware platform. To the clinician this means that he gets all relevant information from one source i.e. the Respiratory Workstation. The waveforms of the airway pressure, airway flow and the expired CO2 curve are displayed continuously on the screen. The Vector Loops like Pressure Volume, Flow Pressure and Flow Volume loops are also available in addition to the lung mechanics parameters like Expiratory and Inspiratory Resistances, Compliance, Peak Pressure, PEEP, etc. The Single Breath Diagram i.e. expired CO2 concentration versus volume and dead space ventilation is also calculated. The blood gas analysis data is plotted in convenient diagrams like the O2–CO2 diagram, Oxygen Chart, etc. The trend of all these parameters are available with a granularity of one minute. An industry standard laser printer is used for report generation to produce reports of the real-time waveforms, parameter values and the trends. User interface is through easy menus with the traditional keyboard, touchscreen including keyborad on screen for data entry and the mouse. 相似文献
2.
Zaver M Bhujwalla Dmitri Artemov Kshama Natarajan Meiyappan Solaiyappan Peggy Kollars Paul E G Kristjansen 《Clinical cancer research》2003,9(1):355-362
PURPOSE: The availability of noninvasive techniques to detect the effects of antiangiogenic agents is critically important for optimizing treatment of cancer with these agents. Magnetic resonance imaging (MRI) is one such noninvasive technique that is routinely used clinically. EXPERIMENTAL DESIGN: In this study, we have evaluated the use of MRI of the intravascular contrast agent albumin-GdDTPA to detect the effects of the antiangiogenic agent TNP-470 on the vascular volume and permeability of the MatLyLu prostate cancer model. RESULTS: TNP-470-treated tumors demonstrated a significant decrease of vascular volume, as well as a significant reduction in vascular and permeable regions, compared with volume-matched control tumors. Although the fractional volume of permeable regions in the tumor decreased, the average value of tumor permeability did not decrease significantly. This was attributable to increase in permeability in some regions of the tumor. These regions were mostly associated with low vascular volume. ELISA assays of control and treated MatLyLu tumors also detected a significant increase of vascular endothelial growth factor in the TNP-470-treated tumors. CONCLUSION: MRI detected significant changes in tumor vascular characteristics after treatment with TNP-470. 相似文献
3.
4.
Imaging cortical association tracts in the human brain using diffusion-tensor-based axonal tracking. 总被引:21,自引:0,他引:21
Susumu Mori Walter E Kaufmann Christos Davatzikos Bram Stieltjes Laura Amodei Kim Fredericksen Godfrey D Pearlson Elias R Melhem Meiyappan Solaiyappan Gerald V Raymond Hugo W Moser Peter C M van Zijl 《Magnetic resonance in medicine》2002,47(2):215-223
Diffusion-tensor fiber tracking was used to identify the cores of several long-association fibers, including the anterior (ATR) and posterior (PTR) thalamic radiations, and the uncinate (UNC), superior longitudinal (SLF), inferior longitudinal (ILF), and inferior fronto-occipital (IFO) fasciculi. Tracking results were compared to existing anatomical knowledge, and showed good qualitative agreement. Guidelines were developed to reproducibly track these fibers in vivo. The interindividual variability of these reconstructions was assessed in a common spatial reference frame (Talairach space) using probabilistic mapping. As a first illustration of this technical capability, a reduction in brain connectivity in a patient with a childhood neurodegenerative disease (X-linked adrenoleukodystrophy) was demonstrated. 相似文献
5.
OBJECTIVE: The purpose of this study was to develop geometric indices, based on morphologic measurements, of contrast-enhanced breast lesions using three-dimensional magnetic resonance imaging (MRI) that can statistically differentiate between benign and malignant lesions. METHODS: Thirty-three patients with abnormal mammograms were scanned using three-dimensional MRI. The lesion was then extracted from the volume data set using interactive volume-rendering software. From the extracted region of interest, the surface boundary corresponding to the lesion was extracted using an isosurface method. The boundary was represented as a triangular mesh, from which the surface area and volume enclosed by the surface were computed. The following variables were tested for discrimination ability between benign and malignant lesions: 1) the volume-to-surface area (V/S) ratio, 2) spherical shape index (SSI), and 3) resolution reduction for V/S and SSI values (100%, 16%, 8%, 4%, 2%, and 1% resolution). In addition, comparisons were made between the V/S and SSI values at 100% versus their reduced resolutions. RESULTS: Thirty-three subjects (15 malignant tumors and 18 benign tumors) were studied. The SSI index (P = 0.0063) was a significant discriminator for malignancy. The V/S ratio (P = 0.9280) did not seem to be a useful variable in distinguishing benign and malignant masses. The V/S resolution comparisons (P > 0.5897) and the SSI resolution comparisons (P > 0.05) were also not useful discriminating variables. CONCLUSION: The SSI seems to be a useful factor in differentiating between benign and malignant lesions. Current clinical interpretation of breast lesions using MRI may be enhanced by the adjunctive use of this objective postanalysis method. 相似文献
6.
Kraitchman DL Chin BB Heldman AW Solaiyappan M Bluemke DA 《Journal of magnetic resonance imaging : JMRI》2002,15(2):149-158
PURPOSE: To assess the value of an intravascular, albumin-targeted contrast agent, MS-325, in visualizing myocardial ischemia with magnetic resonance imaging (MRI). MATERIALS and METHODS: Left anterior descending coronary artery (LAD) stenosis was created in 19 pigs using a closed-chest modified angioplasty technique. Myocardial ischemia was detected by first-pass, contrast-enhanced MRI at peak dipyridamole stress and was compared to Technetium-99m (Tc-99m) sestamibi single photon emission computed tomography (SPECT). Regional coronary blood flow was determined using microspheres. RESULTS: Inducible myocardial ischemia with >40% reduction in stress myocardial blood flow was created in eight animals. An MRI defect, classified as > or=75% reduction in peak myocardial signal intensity in the affected territory, was detected in 92.3% of these animals. In the presence of mild coronary stenosis, there was uniform enhancement with MRI and tracer uptake by SPECT. Concordance of MRI and SPECT for detecting perfusion defects was 85%. CONCLUSION: The pattern of prolonged and persistent MR hypoenhancement of the ischemic myocardial bed using MS-325, which is retained primarily in the vascular bed due to its albumin-binding properties, facilitates the detection of myocardial perfusion defects. 相似文献
7.
Mori S Kaufmann WE Pearlson GD Crain BJ Stieltjes B Solaiyappan M van Zijl PC 《Annals of neurology》2000,47(3):412-414
8.
Beache GM Herzka DA Boxerman JL Post WS Gupta SN Faranesh AZ Solaiyappan M Bottomley PA Weiss JL Shapiro EP Hill MN 《Circulation》2001,104(11):1214-1217
9.
A framework for callosal fiber distribution analysis 总被引:7,自引:0,他引:7
This paper presents a framework for analyzing the spatial distribution of neural fibers in the brain, with emphasis on interhemispheric fiber bundles crossing through the corpus callosum. The proposed approach combines methodologies for fiber tracking and spatial normalization and is applied on diffusion tensor images and standard magnetic resonance images. 相似文献
10.