A case of Scedosporium apiospermum keratitis was successfully treated with oral voriconazole and penetrating keratoplasty. Voriconazole levels in the aqueous humor were 53% of the levels in plasma and exceeded the MIC for the isolate by sevenfold. 相似文献
Heparan sulfate proteoglycans (HSPGs) have been suggested to play an important role in the formation and persistence of senile plaques and neurofibrillary tangles in dementia of the Alzheimer's type (DAT). We performed a comparative immunohistochemical analysis of the expression of the HSPGs agrin, perlecan, glypican-1, and syndecans 1-3 in the lesions of DAT brain neocortex and hippocampus. Using a panel of specific antibodies directed against the protein backbone of the various HSPG species and against the glycosaminoglycan (GAG) side-chains, we demonstrated the following. The basement membrane-associated HSPG, agrin, is widely expressed in senile plaques, neurofibrillary tangles and cerebral blood vessels, whereas the expression of the other basement membrane-associated HSPG, perlecan, is lacking in senile plaques and neurofibrillary tangles and is restricted to the cerebral vasculature. Glypican and three different syndecans, all cell membrane-associated HSPG species, are also expressed in senile plaques and neurofibrillary tangles, albeit at a lower frequency than agrin. Heparan sulfate GAG side chains are also associated with both senile plaques and neurofibrillary tangles. Our results suggest that glycosaminoglycan side chains of the HSPGs agrin, syndecan, and glypican, but not perlecan, may play an important role in the formation of both senile plaques and neurofibrillary tangles. In addition, we speculate that agrin, because it contains nine protease-inhibiting domains, may protect the protein aggregates in senile plaques and neurofibrillary tangles against extracellular proteolytic degradation, leading to the persistence of these deposits. 相似文献
Summary After screening two local populations in the northern part of The Netherlands for hypertension, patients with a diastolic pressure (DP) between 95 and 120 mmHg were treated daily either with 50 mg hydrochlorothiazide or 100 mg atenolol. Non-responders were given the combination and if necessary the dose of atenolol was increased to 200 mg. Non-responders to the latter combination were randomized and treated either with 50 mg hydrochlorothiazide and labetalol or with 50 mg hydrochlorothiazide, 200 mg atenolol and prazosin. If after 1 month a DP90 mmHg had been reached the patient was reassessed after a further 3 months. If a DP>90 mmHg was found the dose of labetalol or prazosin was increased and the patient was re-examined after 1 month.This protocol was followed until the maximum dose was reached or adverse reactions prevented a further increase in dosage.During 6 months of treatment there was a further drop in systolic and diastolic blood pressures under both regimens of, respectively, 8.6 and 2.4 mmHg for labetalol, and 7.7 and 5.0 mmHg for the prazosin group. At the end of the period the average daily doses of labetalol and prazosin were 1256 mg and 4.3 mg, respectively. There was no significant difference in the average number of complaints between the labetalol and the prazosin group. 相似文献
Accurate accelerometer-based methods are required for assessment of 24-h physical behavior in young children. We aimed to summarize evidence on measurement properties of accelerometer-based methods for assessing 24-h physical behavior in young children.
Methods
We searched PubMed (MEDLINE) up to June 2021 for studies evaluating reliability or validity of accelerometer-based methods for assessing physical activity (PA), sedentary behavior (SB), or sleep in 0–5-year-olds. Studies using a subjective comparison measure or an accelerometer-based device that did not directly output time series data were excluded. We developed a Checklist for Assessing the Methodological Quality of studies using Accelerometer-based Methods (CAMQAM) inspired by COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN).
Results
Sixty-two studies were included, examining conventional cut-point-based methods or multi-parameter methods. For infants (0—12 months), several multi-parameter methods proved valid for classifying SB and PA. From three months of age, methods were valid for identifying sleep. In toddlers (1—3 years), cut-points appeared valid for distinguishing SB and light PA (LPA) from moderate-to-vigorous PA (MVPA). One multi-parameter method distinguished toddler specific SB. For sleep, no studies were found in toddlers. In preschoolers (3—5 years), valid hip and wrist cut-points for assessing SB, LPA, MVPA, and wrist cut-points for sleep were identified. Several multi-parameter methods proved valid for identifying SB, LPA, and MVPA, and sleep.
Despite promising results of multi-parameter methods, few models were open-source. While most studies used a single device or axis to measure physical behavior, more promising results were found when combining data derived from different sensor placements or multiple axes.
Conclusions
Up to age three, valid cut-points to assess 24-h physical behavior were lacking, while multi-parameter methods proved valid for distinguishing some waking behaviors. For preschoolers, valid cut-points and algorithms were identified for all physical behaviors. Overall, we recommend more high-quality studies evaluating 24-h accelerometer data from multiple sensor placements and axes for physical behavior assessment. Standardized protocols focusing on including well-defined physical behaviors in different settings representative for children’s developmental stage are required. Using our CAMQAM checklist may further improve methodological study quality.
Sentinel lymph node biopsy (SLNB) without further axillary dissection in patients with sentinel node-negative breast carcinoma appears to be a safe procedure to ensure locoregional control. During a median follow-up of 35 months the false-negative rate was 1% in our study population of 185 patients. BACKGROUND: The objective of this prospective study is to provide data on follow-up of patients with primary operable breast carcinoma staged with SLNB without axillary lymph node dissection (ALND) if the sentinel lymph nodes (SLNs) were tumour-negative. METHODS: One hundred and eighty-five patients were enrolled. Preoperative dynamic and static lymphoscintigraphy were performed; both a vital blue dye and a gamma detection probe were used intraoperatively. Patients with tumour-positive SLNs received completion ALND or if no SLNs could be identified. All patients were monitored according to regional follow-up protocols. RESULTS: The SLNs were identified in 179 out of the 185 patients. In 73 patients the SLNs were tumour-positive and in 106 patients tumour-negative. The median follow-up was 35 months (range 17-59). In one SLN-negative patient an axillary recurrence occurred 26 months after the SLNB (false-negative rate: 1%). CONCLUSIONS: SLNB without ALND appears to be a safe procedure to ensure locoregional control in SLN-negative breast carcinoma, if carried out by an experienced team. 相似文献
We report a severe acute respiratory syndrome coronavirus 2 superspreading event in the Netherlands after distancing rules were lifted in nightclubs, despite requiring a negative test or vaccination. This occurrence illustrates the potential for rapid dissemination of variants in largely unvaccinated populations under such conditions. We detected subsequent community transmission of this strain. 相似文献
18F-FDG PET has gained acceptance for staging of esophageal cancer. However, FDG is not tumor specific and false-positive results may occur by accumulation of FDG in benign tissue. The tracer 18F-fluoro-3'-deoxy-3'-L-fluorothymidine (18F-FLT) might not have these drawbacks. The aim of this study was to investigate the feasibility of 18F-FLT PET for the detection and staging of esophageal cancer and to compare 18F-FLT PET with 18F-FDG PET. Furthermore, the correlation between 18F-FLT and 18F-FDG uptake and proliferation of the tumor was investigated. METHODS: Ten patients with biopsy-proven cancer of the esophagus or gastroesophageal junction were staged with CT, endoscopic ultrasonography, and ultrasound of the neck. In addition, all patients underwent a whole-body 18F-FLT PET and 18F-FDG PET. Standardized uptake values were compared with proliferation expressed by Ki-67 positivity. RESULTS: 18F-FDG PET was able to detect all esophageal cancers, whereas 18F-FLT PET visualized the tumor in 8 of 10 patients. Both 18F-FDG PET and 18F-FLT PET detected lymph node metastases in 2 of 8 patients. 18F-FDG PET detected 1 cervical lymph node that was missed on 18F-FLT PET, whereas 18F-FDG PET showed uptake in benign lesions in 2 patients. The uptake of 18F-FDG (median standardized uptake value [SUV(mean)], 6.0) was significantly higher than 18F-FLT (median SUV(mean), 3.4). Neither 18F-FDG maximum SUV (SUV(max)) nor 18F-FLT SUV(max) correlated with Ki-67 expression in the linear regression analysis. CONCLUSION: In this study, uptake of 18F-FDG in esophageal cancer is significantly higher compared with 18F-FLT uptake. 18F-FLT scans show more false-negative findings and fewer false-positive findings than do 18F-FDG scans. Uptake of 18F-FDG or 18F-FLT did not correlate with proliferation. 相似文献