首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   27篇
  免费   1篇
儿科学   1篇
基础医学   4篇
临床医学   3篇
内科学   2篇
神经病学   9篇
外科学   2篇
预防医学   1篇
眼科学   3篇
药学   3篇
  2016年   2篇
  2015年   1篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2006年   1篇
  2005年   2篇
  2004年   1篇
  2003年   1篇
  2002年   1篇
  2001年   2篇
  2000年   2篇
  1999年   1篇
  1996年   1篇
  1995年   1篇
  1994年   2篇
  1993年   1篇
  1992年   1篇
  1979年   1篇
  1976年   1篇
  1974年   1篇
  1973年   1篇
  1972年   1篇
排序方式: 共有28条查询结果,搜索用时 15 毫秒
1.
Using liquid ion-exchanger semimicroelectrodes with a side pore, we measured changes of extracellular potassium concentration (Ke +) in adult rabbit and cat gastrocnemius muscles and in venous effluent blood flowing from the cat gastrocnemius muscle during various bouts of activity induced by sciatic nerve stimulation.
1.  Isometric tetanic contractions (at 50 Hz) of various durations caused transient accumulation of Ke + which was non-linearly related to the duration of muscle activity. The peak values of Ke + in response to muscle stimulation were analogous in rabbits and cats, attaining values, e.g. after a 20-s isometric tetanus, between 8–9 mEq/lK+ in both species.
2.  Potassium concentration in venous effluent blood (K ven + ) was transiently increased after isometric tetani. Since blood flow was measured at the same time, it was possible to calculate the amount of K+ lost by the muscle after tetani of various durations. A 32 g gastrocnemius muscle of the cat, for example, loses 9.36±1.52 EqK+ after a 20-s isometric tetanus, which corresponds roughly to 0.5% of the total muscle potassium content. The loss of K+ in this muscle was 29.3 pEq K+/impulse/100 g fresh muscle tissue.
3.  There was no evident difference between the amount of K+ released during isometric tetani, or tetanic contractions performed under isotonic conditions. Single twitches evoked by indirect stimulation at 1 Hz for several minutes also induced a small rise in K ven + .
4.  If the loss of K+ from the muscle into the blood stream is transiently prevented by arterio-venous occlusion installed immediately before a 10-s isometric tetanus, most K+ is released subsequently when blood flow is renewed, if the occlusion lasts for 20–25 s. It is not until blood flow is occluded for 40–60 s that most K+ is apparently resorbed and only a minor portion is released and is to be found in the venous blood.
5.  The transient accumulation of muscle extracellular potassium may locally affect nerve endings, skeletal and smooth muscle cells.
  相似文献   
2.
3.
4.
BACKGROUND: Human cytomegalovirus (CMV) is a significant cause of morbidity and mortality among transplant recipients. Monitoring transplant recipients by CMV IgM serology has been questioned by several studies due to the reported insensitivity of serologic tests relative to antigen detection methods. METHODS: In this retrospective study, we have evaluated the performance of the new recombinant antigen-based Abbott AxSYM CMV IgM assay and compared it with CMV culture technique in a cohort of 40 liver transplant recipients who did not receive antiviral prophylaxis. RESULTS: The sensitivity, specificity, and positive and negative predictive values for detection of CMV disease by the AxSYM CMV IgM assay were 90.0%, 60.0%, 69.2%, and 85.7%, respectively, and by culture the values were 100%, 55.0%, 69.0%, and 100%, respectively. Detection of CMV IgM occurred before or at the time of CMV disease in only R+ recipients. CONCLUSION: Although this assay is a sensitive test for CMV-specific IgM, detection of CMV IgM preceded detection of virus by culture in patients only when the liver transplant recipient was CMV immune before transplantation (R+).  相似文献   
5.
Among 460 children who had an orchiopexy (ORP), we identified 72 children who had attended our institution 1–12 years earlier and in whom the testicular position had been specified. Of the 72 boys 19 were had ascended testes (26%). The age at ORP of the children with ascent of the testes was 7.0 years (1.8–14.0 years). Light and electron microscopy of 13 testicular biopsies taken at ORP, showed alterations of germ cells and sertoli cells, similar but less pronounced than alterations seen in congenital undescended testes.Conclusion A normally positioned testis may ascend into the inguinal region or upper scrotum and remain there fixed. This secondary cryptorchidism does not usually respond to human chorionic gonadotropin treatment and must be corrected by orchiopexy.  相似文献   
6.
Summary Modified Walker's liquid ion-exchanger microelectrodes were employed for measuring changes of K+ concentration in venous effluent blood from the cat gastrocnemius muscle during and after isometric tetani of various duration induced by indirect stimulation. The time course of these changes was obtained and the overall loss of K+ from a working muscle could thus be estimated. By comparing present results in the venous blood and previous findings of K+ concentration changes in the muscle extracellular space, a concentration gradient was found between the muscle and venous effluent blood.The authors wish to acknowledge the assistance of Dr. J. L. Walker in developing the ion-specific microelectrodes and for supplying them with silicone oil and Corning ion-exchanger.  相似文献   
7.
8.
We performed a prospective, randomized study comparing the efficacy and safety of remifentanil, propofol or both for conscious sedation during eye surgery under retrobulbar blockade. Forty-five unpremedicated patients were assigned to receive remifentanil (group R) (n = 15, mean dosage: 0.05 +/- 0.03 microgram kg-1 min-1), propofol (group P) (n = 15, 1.5 +/- 0.5 mg kg-1 h-1) or a combination (group RP) (n = 15, R: 0.03 +/- 0.01 microgram kg-1 min-1; P: 0.7 +/- 0.2 mg kg-1 h-1). Haemodynamic responses were comparable among all groups. Minimum values for respiratory rate were lower in R patients (R: 7 vs. P and RP: 10 breaths min-1). Perioperative blood gas analysis showed differences in maximum carbon dioxide tensions (R: 51.5 vs. P: 48.3 vs. RP: 45.5 mmHg) and decrease in minimum pH values (R: -0.06 vs. P: -0.0 vs. RP: -0.01). All group P patients reported mild to intense pain during retrobulbar block, while 53% of the group R patients were free from pain. In group RP, 60% of patients experienced no pain and the remaining 40% reported mild pain only. Remifentanil, applied as the sole agent, provided superior pain relief and patient comfort when compared with propofol, but produced greater respiratory depression and postoperative nausea. The combination of remifentanil and propofol provided haemodynamic stability, adequate spontaneous respiration and pain relief, with a low risk of untoward side effects.  相似文献   
9.
10.
Inhibitors of acetylcholinesterase are compounds widely used in the treatment of various diseases, such as Alzheimer’s disease, glaucoma and Myasthenia gravis (MG). Compounds used in the therapy of MG posses a positive charge in the molecule to ensure peripheral effect of action and minimal blood-brain barrier penetration. The most prescribed carbamate inhibitors are however known for many severe side effects related to the carbamylation of AChE. This paper describes preparation and in vitro evaluation of 20 newly prepared bis-isoquinolinium inhibitors of potential concern for MG.The newly prepared compounds were evaluated in vitro on human recombinant AChE and human plasmatic butyrylcholinesterase (BChE). Their inhibitory ability was expressed as IC50 and compared to chosen standards ambenonium dichloride, edrophonium chloride, BW284c51 and ethopropazine hydrochloride. Three novel compounds presented promising inhibition (in nM range) of both enzymes in vitro better or similar to edrophonium and BW284c51, but worse to ambenonium. The novel inhibitors did not present higher selectivity toward AChE or BChE. The kinetic assay confirmed non-competitive inhibition of hAChE by two selected promising novel compounds. Two newly prepared compounds were also chosen for docking studies that confirmed apparent π-π or π-cationic interactions aside the cholinesterases catalytic sites. The SAR findings were discussed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号