Abstract Perioscan requires a plaque sample to detect the presence of enzymes capable of degrading N-benzoyl-DL-arginine-2-naphthylamide (BANA) from relatively few anaerobic periodontal pathogens. Periocheck assays the presence of neutral proteases in crevicular fluid. The aim of this study was to compare these test kits with traditional clinical methods of detecting periodontal disease and to monitor the ability of the kits to reflect the response to initial therapy. 19 patients with moderately severe chronic periodontitis were seen before and after a course of oral hygiene and root instrumentation consisting of 4 appointments. Clinical measurements and test assays were collected at 5 diseased sites and 2 healthy sites in each subject. Complete data from 125 sites were available for statistical analysis. At baseline Periocheck had a sensitivity of 88% and a specificity of 61% whereas Perioscan had a sensitivity of 99% and a specificity of 55%, when related to the clinical diagnosis. A composite clinical assessment, based on improvement or deterioration of one whole unit change of the subjective clinical indices and 2mm changes or greater in probing depth or probing attachment level, revealed 75 sites which improved following treatment, whereas 45 sites did not change and 5 sites deteriorated. The probability that the tests agreed with the clinical outcome after treatment, was calculated as 50.4% for Periocheck and 52% for Perioscan. The diagnostic kits did not reliably reflect the clinical assessment of periodontal disease in the cross sectional study, or the outcome following treatment. 相似文献
Background: General anesthetics inhibit evoked release of classic neurotransmitters. However, their actions on neuropeptide release in the central nervous system have not been well characterized.
Methods: The effects of representative intravenous and volatile anesthetics were studied on the release of sulfated cholecystokinin 8 (CCK8s), a representative excitatory neuropeptide, from isolated rat cerebrocortical nerve terminals (synaptosomes). Basal, elevated KCl depolarization-evoked and veratridine-evoked release of CCK8s from synaptosomes purified from rat cerebral cortex was evaluated at 35[degrees]C in the absence or presence of extracellular Ca2+. CCK8s released into the incubation medium was determined by enzyme-linked immunoassay after filtration.
Results: Elevation of extracellular KCl concentration (to 15-30 mm) or veratridine (10-20 [mu]m) stimulated Ca2+-dependent CCK8s release. Basal, elevated KCl- or veratridine-evoked CCK8s release was not affected significantly by propofol (12.5-50 [mu]m), pentobarbital (50 and 100 [mu]m), thiopental (20 [mu]m), etomidate (20 [mu]m), ketamine (20 [mu]m), isoflurane (0.6-0.8 mm), or halothane (0.6-0.8 mm). 相似文献
The present study was designed to detect three single nucleotide polymorphisms (SNPs) located on 22q11 that was thought as being of particularly importance for genetic research into schizophrenia. We recruited a total of 176 Chinese family trios of Han descent, consisting of mothers, fathers and affected offspring with schizophrenia for the genetic analysis. The transmission disequilibrium test (TDT) showed that of three SNPs, rs10314 in the 3'-untranslated region of the CLDN5 locus was associated with schizophrenia (chi(2) = 4.75, P = 0.029). The other two SNPs, rs1548359 present in the CDC45L locus centromeric of rs10314 and rs739371 in the 5'-flanking region of the CLDN5 locus, did not show such an association. The global chi-square (chi(2)) test showed that the 3-SNP haplotype system was not associated with schizophrenia although the 1-df test for individual haplotypes showed that the rs1548359(C)-rs10314(G)-rs739371(C) haplotype was excessively non-transmitted (chi(2) = 5.32, P = 0.02). Because the claudin proteins are a major component for barrier-forming tight junctions that could play a crucial role in response to changing natural, physiological and pathological conditions, the CLDN5 association with schizophrenia may be an important clue leading to look into a meeting point of genetic and environmental factors. 相似文献
Dopamine inhibits Na+,K(+)-ATPase activity in several renal tubule segments and thereby regulates urinary Na+ excretion. We now show that a phosphopeptide of 31 amino acids, corresponding to residues 8-38 of the protein phosphatase inhibitor DARPP-32 (dopamine- and cAMP-regulated phosphoprotein of Mr 32,000), mimics the inhibitory action of dopamine on Na+,K(+)-ATPase activity in renal tubule cells from the ascending limb of the loop of Henle. The dephosphorylated form of the peptide is ineffective. The results indicate that dopamine acts through a protein phosphorylation pathway to regulate the activity of an ion pump. In addition, the data suggest that inhibition of protein phosphatase 1 by phophorylated DARPP-32 is a component of the mechanism by which dopamine regulates urinary Na+ excretion. 相似文献
Gastroesophageal reflux disease (GERD) is the most common disease of the upper gastrointestinal tract. With the introduction of proton pump inhibitors medical treatment of GERD has been significantly improved. However, the development of laparoscopic antireflux surgery resulted in an increasing interest of surgeons in this disease. An interactive meeting was organized in order to develop an agreement between gastoenterologists and surgeons regarding therapeutic decisions and this is the main topic of this paper. 相似文献
Flow-phantom magnetic resonance (MR) imaging, with use of both spin-echo (SE) and gradient-echo (GRE) techniques at 1.5 T, was performed on the percutaneous Greenfield (beta-III titanium alloy [TMA wire]), Amplatz (MP32-N alloy), and Simon nitinol filters and TMA wire facsimiles of the bird's nest, Gunther, new retrievable, and Amplatz vena caval filters. SE imaging allowed detection of thrombi as small as 5 X 5 mm trapped within the percutaneous Greenfield, Simon nitinol, and TMA-wire facsimile filters; with the MP32-N Amplatz filter, a larger volume of thrombus (10 X 20-mm clots) was necessary for clot detection. GRE imaging allowed detection of intraluminal tilting of the percutaneous Greenfield and facsimile Amplatz (TMA-wire) filters. GRE imaging was useful for demonstrating postfilter turbulence due to clots, which was greatest for the Amplatz filter. Imaging of facsimile vascular devices made of tantalum or TMA wire did not cause the severe "black-hole" MR artifacts typical of the stainless-steel devices. SE and GRE imaging were very useful for determining caval patency in two patients with previously placed Mobin-Uddin filters. Noninvasive MR evaluation of blood vessels in the presence of a variety of low-artifact intravascular devices appears feasible. 相似文献