Purpose: To use polymerase chain reaction (PCR) and Goldmann-Witmer coefficient (GWC) calculation to diagnose infectious uveitis.
Methods: Prospective cross-sectional study.
Results: Twenty-seven of 106 patients had positive PCR and/or GWC results on aqueous humor (AH) sampling and 15 of 27 (55.6%) were HIV-positive. Patients with non-anterior uveitis (NAU) were more likely to be HIV+ (p = 0.005). More than 1 possible pathogen was identified in 9 of 27 patients of whom 7 were HIV+. The final clinical diagnosis was discordant with AH findings in 9 of 27 cases. A positive EBV PCR result was associated with a discordant diagnosis (p = 0.001). All cases of herpetic anterior uveitis (42.9% HIV+) tested PCR-/GWC+ while all cases of herpetic NAU tested PCR+/GWC- (83.3% HIV+). All rubella virus cases were PCR+/GWC+.
Conclusion: PCR is useful to diagnose herpetic NAU in HIV+ patients while GWC is useful to diagnose herpetic anterior uveitis. 相似文献
Maternal and Child Health Journal - Background Prenatal substance use screening is recommended. The 4 P’s Plus screener includes questions on perceived problematic substance use in parents... 相似文献
Motion is a major confound in diffusion‐weighted imaging (DWI) in the body, and it is a common cause of image artefacts. The effects are particularly severe in cardiac applications, due to the nonrigid cyclical deformation of the myocardium. Spin echo‐based DWI commonly employs gradient moment‐nulling techniques to desensitise the acquisition to velocity and acceleration, ie, nulling gradient moments up to the 2nd order (M2‐nulled). However, current M2‐nulled DWI scans are limited to encode diffusion along a single direction at a time. We propose a method for designing b‐tensors of arbitrary shapes, including planar, spherical, prolate and oblate tensors, while nulling gradient moments up to the 2nd order and beyond. The design strategy comprises initialising the diffusion encoding gradients in two encoding blocks about the refocusing pulse, followed by appropriate scaling and rotation, which further enables nulling undesired effects of concomitant gradients. Proof‐of‐concept assessment of in vivo mean diffusivity (MD) was performed using linear and spherical tensor encoding (LTE and STE, respectively) in the hearts of five healthy volunteers. The results of the M2‐nulled STE showed that (a) the sequence was robust to cardiac motion, and (b) MD was higher than that acquired using standard M2‐nulled LTE, where diffusion‐weighting was applied in three orthogonal directions, which may be attributed to the presence of restricted diffusion and microscopic diffusion anisotropy. Provided adequate signal‐to‐noise ratio, STE could significantly shorten estimation of MD compared with the conventional LTE approach. Importantly, our theoretical analysis and the proposed gradient waveform design may be useful in microstructure imaging beyond diffusion tensor imaging where the effects of motion must be suppressed. 相似文献
Abstract The purpose of this study was to investigate the strength of the relationships between self-efficacy and (i) functional exercise capacity and (ii) physical activity in chronic obstructive pulmonary disease (COPD), and whether self-efficacy assessment type (i.e., COPD symptoms, exercise-task, exercise-barrier, general, falls) and physical activity assessment type (i.e., self-report vs. objective) are moderators. A systematic search of COPD and self-efficacy concepts was conducted using eight databases from inception to 23 January 2019. Studies were included if they provided correlation coefficients of the relationship between self-efficacy and functional exercise capacity or physical activity, were conducted in adults diagnosed with COPD, and were published in English-language journals. A total of 14 correlation coefficients were included in the self-efficacy and functional exercise capacity meta-analysis, and 16 in the self-efficacy and physical activity meta-analysis. Data were screened, reviewed, and extracted independently by two reviewers, with discrepancies resolved by a third reviewer. Stronger self-efficacy was associated with better functional exercise capacity (weighted r?=?0.38, 95%CI [0.25, 0.50]), and greater physical activity (weighted r?=?0.25, 95%CI [0.17, 0.34]). Exercise-task self-efficacy had the strongest relationship to functional exercise capacity (weighted r?=?0.64, 95% CI [0.51, 0.73]). For physical activity, the type of self-efficacy most strongly related was inconclusive. In COPD, self-efficacy has a relationship to functional exercise capacity and physical activity, the strength of which is influenced by the choice of self-efficacy measure. An understanding of these relationships will assist clinicians in selecting the self-efficacy measure most closely related to the outcome of interest. 相似文献
I discuss various viewpoints of physically disabled and nondisabled persons. I then question which views to preserve and which need to be changed as regards the subject of supervision of the physically disabled. I believe that illness and/or being physically disabled require different definitions and that for many physically disabled persons there is no either-or. In various theories it is asked how the physically disabled can be supported in their personal development, when it is maintained held that both disabled and non-disabled persons have the same mental and emotional conditions and requirements. The following theories will be considered: role theory, labeling theory, which holds to the idea of "self-fulfilling prophesy", the concept of the five pillars of identity, the expectations of self-effectiveness and of results and the theory of internal locus of control. It is a question of whether the physically disabled, like the nondisabled, should take the responsibility for their personal development upon themselves. In closing, I discuss where supervision can have a supportive effect in helping the physically disabled achieve greater personal development. Personal development improves the quality of life. Supervision for those who work with the physically disabled should contribute to reaching these goals. 相似文献
In order to assess the histological tissue changes over time around the site of implant, tissue biopsies were taken at 1 to 38 months post-implant from 54 (34 male) consenting human subjects who had received the Australian subcutaneous naltrexone-poly(DL-lactide) implant for heroin dependence. The implant consists of multiple tablets containing compressed naltrexone-poly[trans-3,6-dimethyl-1,4-dioxane-2,5-dione] (DL-lactide) loaded microspheres. Assessment of tissue samples by pathologists showed an early phase (up to 12 months post-implant) of inflammation, foreign body reaction, and fibrosis. This subsided gradually over the next 12 months until tissue returned to normal by 25+ months. Sufficient evidence was not available to conclude that the poly(DL-lactide) implant matrix was totally biodegradable within the study period. While implant material was not identified in most of the latter biopsies, its presence was noted in one biopsy at 26 months post-implant. Nevertheless the study results did demonstrate the implant's biocompatibility by the lack of inflammation, foreign body reaction, and fibrosis detected by 25+ months. It seems highly probable that surgical technique rather than the implant itself was associated with the additional finding of fat necrosis. Moderate fat necrosis was observed as a common feature of biopsies carried out during the first 6 months following implant. It subsided to mild levels over the next 18 months, and was notably absent by 25+ months. The results of the study indicated that the Australian naltrexone-poly(DL-lactide) implant is well tolerated and may have a role for use in the management of medical conditions such as heroin dependence. 相似文献
BACKGROUND: Studies of the association between indoor allergen exposure and the development of allergic diseases have often measured allergen exposure at one point in time. OBJECTIVE: We investigated the variability of house dust mite (Der p 1, Der f 1) and cat (Fel d 1) allergen in Dutch homes over a period of 8 years. METHODS: Data were obtained in the Dutch PIAMA birth cohort study. Dust from the child's mattress, the parents' mattress and the living room floor was collected at four points in time, when the child was 3 months, 4, 6 and 8 years old. Dust samples were analysed for Der p 1, Der f 1 and Fel d 1 by sandwich enzyme immuno assay. RESULTS: Mite allergen concentrations for the child's mattress, the parents' mattress and the living room floor were moderately correlated between time-points. Agreement was better for cat allergen. For Der p 1 and Der f 1 on the child's mattress, the within-home variance was close to or smaller than the between-home variance in most cases. For Fel d 1, the within-home variance was almost always smaller than the between-home variance. Results were similar for allergen levels expressed per gram of dust and allergen levels expressed per square metre of the sampled surface. Variance ratios were smaller when samples were taken at shorter time intervals than at longer time intervals. CONCLUSION: Over a period of 4 years, mite and cat allergens measured in house dust are sufficiently stable to use single measurements with confidence in epidemiological studies. The within-home variance was larger when samples were taken 8 years apart so that over such long periods, repetition of sampling is recommended. 相似文献