Introduction: Allergic rhinitis is a common condition with increasing prevalence and is associated with several comorbid disorders such as bronchial asthma and atopic dermatitis. If allergen avoidance is not possible, allergen-specific immunotherapy is the only causal treatment option.
Areas covered: This review focuses on current treatments and the future outlook for allergic rhinitis. Pharmacotherapy includes mast cell stabilizers, antihistamines, glucocorticosteroids (GCSs), leukotriene receptor antagonists, and nasal decongestants. Nasal GCSs are currently regarded as the most effective treatment and are considered first-line therapy together with non-sedating antihistamines. The new formulation MP29-02 combines the nasal GCS fluticasone propionate with azelastine in one single spray and has achieved greater improvements than those under monotherapy with modern GCSs or antihistamines. Furthermore, this review discusses allergen immunotherapy alone and in combination with modern monoclonal antibodies.
Expert opinion: Despite the variety of medications for allergic rhinitis, ranging from general symptomatic agents like GCSs or decongestants, to more specific ones like histamine receptor or leukotriene blockers, to causal therapy like immunotherapy, many patients still experience treatment failures or unsatisfactory results. The ultimate goal may be to endotype every downstream pathway separately in order to offer patients individualized, targeted therapy with specific antibodies against the respective pathway. 相似文献
Motion is a major confound in diffusion‐weighted imaging (DWI) in the body, and it is a common cause of image artefacts. The effects are particularly severe in cardiac applications, due to the nonrigid cyclical deformation of the myocardium. Spin echo‐based DWI commonly employs gradient moment‐nulling techniques to desensitise the acquisition to velocity and acceleration, ie, nulling gradient moments up to the 2nd order (M2‐nulled). However, current M2‐nulled DWI scans are limited to encode diffusion along a single direction at a time. We propose a method for designing b‐tensors of arbitrary shapes, including planar, spherical, prolate and oblate tensors, while nulling gradient moments up to the 2nd order and beyond. The design strategy comprises initialising the diffusion encoding gradients in two encoding blocks about the refocusing pulse, followed by appropriate scaling and rotation, which further enables nulling undesired effects of concomitant gradients. Proof‐of‐concept assessment of in vivo mean diffusivity (MD) was performed using linear and spherical tensor encoding (LTE and STE, respectively) in the hearts of five healthy volunteers. The results of the M2‐nulled STE showed that (a) the sequence was robust to cardiac motion, and (b) MD was higher than that acquired using standard M2‐nulled LTE, where diffusion‐weighting was applied in three orthogonal directions, which may be attributed to the presence of restricted diffusion and microscopic diffusion anisotropy. Provided adequate signal‐to‐noise ratio, STE could significantly shorten estimation of MD compared with the conventional LTE approach. Importantly, our theoretical analysis and the proposed gradient waveform design may be useful in microstructure imaging beyond diffusion tensor imaging where the effects of motion must be suppressed. 相似文献
10 patients with CLL and 2 with CML were treated with gradually increasing doses of 1 alpha(OH)D3, up to 4 micrograms daily during 6 wk. 3 patients with preleukemia and 1 with myelofibrosis were treated with 2 micrograms daily of 1 alpha(OH)D3 for a prolonged period up to 17 wk. The treatment with 1 alpha (OH)D3 did not result in changes of disease parameters in any of the patients under study. Receptor studies for 1,25(OH)2D3 were performed in 8 CLL patients and revealed only 1 patient with increased specific receptor binding capacity. The maximum tolerable dose of 1 alpha(OH)D3 varied individually, but was in the range of 2-4 micrograms daily. 相似文献
OBJECTIVES: Intraoperative cone-beam computerized tomography (CBCT) imaging has been introduced in oral and maxillofacial surgery. Using midfacial fractures as the pioneer model, this study describes the spectrum of further promising clinical indications for intraoperative CBCT and a clinical combination with intraoperative navigation. STUDY DESIGN: One hundred seventy-nine patients admitted for surgical treatment of the facial skeleton were included in the study. Intraoperatively, 3-dimensional images were generated with the mobile CBCT scanner Arcadis Orbic 3D, obtained from Siemens Medical Solutions, in a variety of indications. RESULTS: The acquisition of the data sets was uncomplicated, and image quality was sufficient to assess the postoperative result in all cases. In the example of a facial gunshot injury, a navigation system for intraoperative localization of the metal foreign bodies was used. 相似文献