首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
儿科学   1篇
妇产科学   1篇
眼科学   1篇
  2002年   1篇
  1992年   1篇
  1987年   1篇
排序方式: 共有3条查询结果,搜索用时 0 毫秒
1
1.
The clinical diagnosis of pelvic inflammatory disease (PID) is associated with an average accuracy rate of 65% when preoperative impressions are confirmed or rejected with laparoscopy. The cost of this error rate should be evaluated when considering the cost and risks of immediate laparoscopy in patients suspected of having PID. This study reviewed selected patient admissions for PID from Northwestern Memorial Hospital for the years 1981-1985. The costs of hospitalization and treatment and the inherent diagnostic error rate were considered concurrently. No significant additional expense would have been incurred if all the women admitted with a clinical diagnosis of PID had had laparoscopic verification of their clinical diagnoses as compared to the cost of treatment with intravenous antibiotics for three to five days. We recommend the early use of laparoscopy in establishing the diagnosis of PID because it ensures a more accurate and definitive diagnosis and does not add significantly to costs.  相似文献   
2.
We describe six boys with homozygous sickle cell disease, aged 7 to 13 years, in whom acute, severe neurologic abnormalities developed 1 to 11 days after partial exchange transfusion was performed to treat priapism that was unresponsive to more conservative therapy. Hemoglobin levels were 10.5 to 13.4 gm/dl (mean 12.1 gm/dl), and hemoglobin S levels were 18% to 33% (mean 27%) before the onset of neurologic complications. Severe headache was the initial finding in five patients, four of whom had increased intracranial pressure and three of whom required tracheal intubation and hyperventilation. Four patients had seizures; three had focal neurologic deficits for more than 24 hours. Cerebral arteriography demonstrated vascular abnormalities, including irregularity, stenosis, and complete occlusion of vessels. Patients treated with regular erythrocyte transfusions had no recurrence of neurologic signs or symptoms when hemoglobin S levels were kept at 30% to 50%. The occurrence of serious neurologic complications after partial exchange transfusion in patients with homozygous sickle cell disease from three centers indicates the possibility of a causal relationship between the events. Early and thorough investigation of neurologic symptoms, especially severe headache, is warranted in this clinical setting.  相似文献   
3.
PURPOSE: Frequency-doubling technology (FDT) perimetry was developed as a screening test for glaucoma. Patients with damage to the neuro-ophthalmic sensory visual pathways have different patterns of visual loss than patients with glaucoma. The current study was designed to determine the sensitivity and specificity of FDT as a screening test, compared with conventional automated perimetry (CAP) in neuro-ophthalmic disorders and to test the extent to which it may isolate the M(y) cells. METHODS: FDT and CAP were performed in 97 patients with sensory neuro-ophthalmic disorders and 42 subjects from the general population. The total and pattern-deviation probability plots for test loci common to the two perimetric tests were compared. The gold standard was an unequivocal clinical diagnosis. RESULTS: The sensitivity of FDT was 81.3%, with a specificity of 76.2%. The difference in sensitivity and specificity of CAP, 87.5% and 81.0%, respectively, was not statistically significant (by chi(2) test). In subjects with optic neuropathies, the similarity of the defect shown on FDT and CAP was judged good or fair in 62 of 72 cases. The extent of the defect as seen with FDT and CAP was equal in 41 of 72 cases, more extensive with FDT in 12, and more extensive with CAP in 19. In the patients with hemianopia, scattered abnormal test locations with FDT testing masked the hemianopic nature of the defect in 15 of 25 patients. Also, test locations along the vertical midline in densely hemianopic areas were seen with FDT testing in some patients with hemianopia, probably due to light scatter across the vertical midline and into the uninvolved hemianopic field. CONCLUSIONS: FDT has sensitivity and specificity similar to that of CAP for detecting visual field defects in patients with optic neuropathies. However, defects in patients with hemianopias may be missed because of the presence of scattered abnormal test locations and failure to detect test locations along the vertical meridian. The defects demonstrated by both tests in patients with optic neuropathies are similar in number, extent, and shape of the defects. This suggests FDT may not be isolating the magnocellular (M) cells with nonlinear responses to stimulus contrast (M(y) cells) in patients with visual loss.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号