首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   337篇
  免费   0篇
  国内免费   3篇
儿科学   9篇
妇产科学   3篇
基础医学   43篇
口腔科学   8篇
临床医学   150篇
内科学   43篇
神经病学   8篇
特种医学   6篇
外科学   30篇
综合类   4篇
预防医学   22篇
药学   14篇
  2023年   17篇
  2022年   23篇
  2021年   49篇
  2020年   28篇
  2019年   36篇
  2018年   34篇
  2017年   13篇
  2016年   7篇
  2015年   11篇
  2014年   27篇
  2013年   17篇
  2012年   13篇
  2011年   11篇
  2010年   4篇
  2009年   18篇
  2008年   5篇
  2007年   8篇
  2006年   6篇
  2005年   3篇
  2004年   4篇
  2003年   1篇
  2002年   3篇
  2001年   1篇
  1998年   1篇
排序方式: 共有340条查询结果,搜索用时 15 毫秒
61.
BACKGROUND: The study aimed to compare the time to overall length of stay (LOS) for patients who underwent point-of-care ultrasound (POCUS) versus radiology department ultrasound (RDUS).METHODS: This was a prospective study on a convenience sample of patients who required pelvic ultrasound imaging as part of their emergency department (ED) assessment.RESULTS: We enrolled a total of 194 patients who were on average 32 years-old. Ninety-eight (51%) patients were pregnant (<20 weeks). Time to completion of RDUS was 66 minutes longer than POCUS (95%CI 60-73, P<0.01). Patients randomized to the RDUS arm experienced a 120 minute longer ED length of stay (LOS) (95%CI 66-173, P<0.01)CONCLUSION: In patients who require pelvic ultrasound as part of their diagnostic evaluation, POCUS resulted in a significant decrease in time to ultrasound and ED LOS.  相似文献   
62.
Multiple electrode aggregometry (MEA) enables rapid platelet function testing in whole blood using 600 μL disposable standard test cells (STC). However, newly available 350μL mini test cells (MTC) could potentially be advantageous in some clinical settings where sample volume is limiting. In order to evaluate the diagnostic performance of MTC, we have estimated assay imprecision, correlation and agreement between area under curve (AUC) determined using MTC and STC in whole blood from healthy donors and from 119 cardiac surgery patients. Imprecision was similar with ADP, AA and TRAP test reagents using STC and MTC, but was markedly higher with the unvalidated ADR reagent. AUC determined using MTC and STC and the ADP, AA and TRAP reagents correlated strongly although MTC yield consistently lower AUC values reflecting fewer platelets in the smaller test cell. Agreement between AUC from STC and MTC was less strong, probably reflecting a composite effect of imprecision from both assay formats. MTC and STC are equally valid for MEA but AUC values obtained using one test format cannot be directly transformed to the other. Therefore, STC and MTC cannot be used interchangeably and AUC results must be compared to separately determined reference intervals.  相似文献   
63.
Intrauterine devices (IUDs) are used worldwide. The 2 types that are used are the levonorgestrel IUD and a copper containing IUD. This is a case study of a 30-year-old female with a levonorgestrel IUD who was diagnosed with a ruptured ectopic pregnancy in the emergency department (ED). Point-of-care urine pregnancy test and point-of-care ultrasound (POCUS) were vital in making this diagnosis and should be utilized in patients assigned female at birth who present with abdominal pain.  相似文献   
64.
床旁即时超声(point-of-care ultrasound, POCUS)的可视性大大提升了临床医师进行气道操作时的安全性和气道管理的精准性。POCUS成为临床医师进行快速诊断与精准治疗的必备技能之一。POCUS技术在新型冠状病毒肺炎爆发时亦发挥重要作用。文章综述了现阶段国内外POCUS技术在上气道解剖结构观察中的...  相似文献   
65.
BackgroundAcute respiratory tract infections (RTIs) are the most common reason to seek medical care, with many patients receiving inappropriate antibiotics. Novel testing approaches to identify aetiology at the point-of-care are required to accurately guide antibiotic treatment.ObjectiveTo assess the diagnostic accuracy of biomarker combinations to rapidly differentiate between acute bacterial or viral RTI aetiology.Data sourcesMEDLINE, Embase and Web of Science databases were searched to February 2021.Study eligibility criteriaDiagnostic accuracy studies comparing accuracy of point-of-care and rapid diagnostic tests in primary or secondary care, consisting of biomarker combinations, to identify bacterial or viral aetiology of RTI.MethodsRisk of bias was assessed using the QUADAS-2 tool. Sensitivity and specificity of tests reported by more than one study were meta-analysed using a random effects model.ResultsTwenty observational studies (3514 patients) were identified. Eighteen were judged at high risk of bias. For bacterial aetiologies, sensitivity ranged from 61% to 100% and specificity from 18% to 96%. For viral aetiologies, sensitivity ranged from 59% to 97% and specificity from 74% to 100%. Studies evaluating two commercial tests were meta-analysed. For ImmunoXpert, the summary sensitivity and specificity were 85% (95% CI 75%–91%, k = 4) and 86% (95% CI 73%–93%, k = 4) for bacterial infections, and 90% (95% CI 79%–96%, k = 3) and 92% (95% CI 83%–96%, k = 3) for viral infections, respectively. FebriDx had pooled sensitivity and specificity of 84% (95% CI 75%–90%, k = 4) and 93% (95% CI 90%–95%, k = 4) for bacterial infections, and 87% (95% CI 72%–95%; k = 4) and 82% (95% CI 66%–86%, k = 4) for viral infections, respectively.ConclusionCombinations of biomarkers show potential clinical utility in discriminating the aetiology of RTIs. However, the limitations in the evidence base, due to a high proportion of studies with high risk of bias, preclude firm conclusions. Future research should be in primary care and evaluate patient outcomes and cost-effectiveness with experimental study designs.Clinical trialPROSPERO registration number: CRD42020178973.  相似文献   
66.
67.
Amniotic fluid embolism is a rare but often catastrophic emergency. The non-specific clinical features and lack of diagnostic tests make it a diagnosis of exclusion. Point-of-care visco-elastometric testing is being increasingly used during obstetric haemorrhage. We present a case of amniotic fluid embolism, diagnosed and managed using rotational thromboelastography. During a precipitous labour, a 21-year-old multiparous woman became pale, distressed and disorientated. The fetus was delivered using forceps. Simultaneously maternal cardiac arrest occurred and advanced life support was commenced. As there was no obvious bleeding, pulmonary embolism was considered the most likely diagnosis and preparation was made to thrombolyse. During resuscitation, rotational thromboelastometry demonstrated haemostatic failure, supporting a diagnosis of amniotic fluid embolism. This reversed the decision to thrombolyse and focused the team on resuscitation and management of coagulopathy. Targeted blood products were given using a local protocol specific to obstetric bleeding. Return of cardiac output was achieved. The total measured blood loss was more than 3.6 L and transfusion was guided by point-of-care tests. Transfused blood products were six units of packed red blood cells, one pool of platelets, 12 units of fresh frozen plasma and 14 g of fibrinogen concentrate. This case demonstrates amniotic fluid embolism with haemostatic failure, without initial revealed blood loss. The high mortality of amniotic fluid embolism necessitates rapid diagnosis and aggressive management. Laboratory tests in this context are impractical in informing clinical decisions, showing the value of point-of-care testing in facilitating team work and timely administration of targeted blood products.  相似文献   
68.
ObjectivesOlder adults have an elevated risk of dehydration, a state with proven detrimental cognitive and physical effects. Furthermore, the use of diuretics by hypertensive patients further compounds this risk. This prospective study investigated the diagnostic accuracy of point-of-care (POC) salivary osmolarity (SOSM) measurement for the detection of dehydration in hypertensive adults with and without diuretic pharmacotherapy.DesignProspective diagnostic accuracy study.SettingHome visits to patients recruited from 4 community health centers in West Sulawesi, Indonesia.ParticipantsA total of 148 hypertensive older adults (57 men, 91 women). The mean ages of male and female patients were 69.4 ± 11.4 and 68.1 ± 7.8 years, respectively.MethodsHypertensive adults were divided into 2 groups based on the presence of diuretics in their pharmacotherapeutic regimen. First-morning mid-stream urine samples were used to perform urine specific gravity (USG) testing. Same-day SOSM measurements were obtained using a POC saliva testing system.ResultsBoth USG (P = .0002) and SOSM (P < .0001) were significantly elevated in hypertensive patients with diuretic pharmacotherapy. At a USG threshold of ≥1.030, 86% of diuretic users were classified as dehydrated compared with 55% of non-using participants. A strong correlation was observed between USG and SOSM measurements (r = 0.78, P < .0001). Using a USG threshold of ≥1.030 as a hydration classifier, an SOSM threshold of ≥93 mOsm had a sensitivity of 78.6% and a specificity of 91.1% for detecting dehydration.Conclusions and ImplicationsHypertensive patients on diuretics have significantly higher first-morning USG and SOSM values, indicating a higher likelihood of dehydration relative to those on other classes of antihypertensive medication. POC SOSM assessment correlates strongly with first-morning USG assessment, and represents a rapid and noninvasive alternative to urinary hydration assessment that may be applicable for routine use in populations with elevated risk of dehydration.  相似文献   
69.
Point-of-care ultrasound (POCUS) is a sensitive, specific tool for early diagnosis of diaphragm pathology in critically ill patients. We report the case of a patient with a history of iatrogenic diaphragmatic hernia who was admitted to the Resuscitation Unit after an emergency exploratory laparotomy. As the diagnosis of diaphragmatic hernia had already been confirmed, we determined the POCUS features that establish the diagnosis of diaphragmatic hernia: (1) normal bilateral diaphragmatic shortening fraction; (2) decreased diaphragmatic excursion, and (3) cephalic position of the diaphragmatic dome (4) greater in supine than in sitting position. We also outline a systematic ultrasound examination of the diaphragm and a POCUS-based differential classification of diaphragmatic dysfunction based on the functional integrity of the peripheral muscle and central diaphragmatic tendon in critically ill patients.  相似文献   
70.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号