Deposits of dental plaque or calculus are typically quantified using planimetric techniques. However, error is introduced into a quantitative analysis of plaque deposits using these methods, since they require a significant amount of human intervention. The purpose of this study is to describe and validate a computerized imaging routine which has the potential to objectively identify material on dental roots and measure the area covered by these deposits. Dentiform teeth with simulated plaque were videorecorded. A computer routine was developed based on a flood-fill algorithm which analyzed images of the dentiform teeth and determined the amount of simulated plaque on their root surfaces. Results showed that the dentiform teeth and their simulated plaque patterns are duplicated by the imaging routine in a rapid and reliable fashion. The system shows a high degree of accuracy with an average error factor of only 0.58%. As well, the system enables precise reproducibility with an average error factor of only 0.71%. 相似文献
We present a case of a female patient suffering from type I complex regional pain syndrome (CRPS) who developed “mirror imaging” of her CRPS and was successfully treated with dual spinal cord stimulation (SCS) in the paraforaminal epidural space. This patient initially had unilateral pain that was unsuccessfully treated with midline SCS and single‐lead lateral epidural lead placement “paraforaminally.” One year later, because we believed that paraforaminal stimulation would preferentially stimulate primary sensitized afferents innervating the painful area, we reperformed SCS with two leads positioned laterally and paraforaminally close to the roots within the epidural space. After repositioning and after 1 year of paraforaminal stimulation, there was significant improvement in the patient's symptoms, resolving all unilateral and “mirrored” symptoms. We conclude that paraforaminal stimulation may be a valid therapeutic option for the treatment of CRPS. 相似文献
目的:建立一种裸鼠前列腺癌骨转移模型,观察肿瘤局部生长和远处转移情况,并进一步探讨其应用价值。方法:9只6周龄雄性BALB/C裸鼠麻醉后,将前肢及左后肢固定,以1 m l TB针筒-29G针头从胫骨头关节窝,刺入骨髓腔缓缓注入人前列腺癌Du145细胞悬液30μl(约5×106个细胞)至骨髓腔,以建立前列腺癌骨转移模型。观察裸鼠生命体征变化。于濒死状态下处死,取右后肢及其附近淋巴结、肺脏和肝脏等标本,用40 m l/L甲醛固定、石蜡包埋、苏木精-伊红染色后显微镜下观察。结果:9只裸鼠中有6只模型建立成功。接种后平均48 d裸鼠出现跛行现象,右后肢胫骨部可触及米粒大小的包块,质硬,进一步发展至小鼠行走障碍。55 d后出现恶病质,解剖后发现右后肢胫骨部骨质疏松,局部有“腐肉”样组织突出髓腔,填塞肌肉间隙,病理证实为肿瘤组织。肝脏泛黄、被膜皱缩,镜下呈急性重型肝炎的病理改变。结论:胫骨内注射细胞悬液制作裸鼠前列腺癌骨转移模型较好地模拟了人前列腺癌在骨骼微环境中的生长及转归情况,是研究前列腺肿瘤骨转移的适宜模型。 相似文献
Study Objective: To test the hypothesis that slow administration of local anesthetic into the epidural space by gravity flow reduces the incidence of signs and symptoms of unintended injection.
Design: Prospective, randomized study.
Setting: Teaching hospital.
Patients: 600 ASA physical status I and II parturients scheduled for labor and delivery or elective cesarean section.
Interventions: After identification of the epidural space with pulsations of an air-fluid column, parturients for vaginal delivery (n = 380) were randomized to receive a test dose of 3 ml 3% 2-chloroprocaine with epinephrine 20 μg, two doses of 7 ml bupivacaine 0.03 % with sufentanil 1 μg/ml and epinephrine 2 μg/ml by either gravity flow (Group 1) given over 30 seconds or by bolus injection (Group 2) given over 5 seconds through the epidural needle; parturients for Cesarean delivery (n = 220) were randomized to receive a test dose and two doses of 6 ml lidocaine 2 % with sufentanil 1 μg/ml and epinephrine 2 μg/ml by either gravity flow or by bolus injection through the epidural needle. Changes in maternal heart rate (HR) and blood pressure, signs of intravascular injection, and adverse effects of epidural bupivacaine-sufentanil were recorded after each dose.
Measurements and Main Results: Gravity flow administration (Group 1) was associated with a smaller increase in mean maternal HR (p < 0.001), less hypotension (p < 0.01), sedation (p < 0.01), nausea (p = 0.01), and segmental spread (p < 0.0001) than were corresponding doses given by traditional bolus injection (Group 1) for vaginal or Cesarean deliveries. The incidence of systemic toxicity was zero of 300 (0%) with gravity flow and 4 of 300 (1.3%) by bolus injection, p = 0.12, Fisher's exact test. No patient in either group had an accidental intrathecal injection.
Conclusion: Gravity flow administration of local anesthetic-opioid solution during epidural block for obstetrics was associated with fewer signs of systemic drug absorption and cardiovascular perturbations than was the traditional bolus injection. This study supports the current opinion that slow administration of local anesthetic during epidural black contributes to fewer adverse events. 相似文献