The events at the hydroxyapatite implant material/tissue interface in the rat middle ear were studied by light microscopy, autoradiography, morphometry, transmission electron microscopy (TEM), scanning electron microscopy (SEM), and X-ray microanalysis. Deposition of calcium, partially in the form of calcium phosphate, was found at the interface. Resorption of the implant material occurred as the result of mono- and multinuclear phagocyte activity. Resorption decreased 6 mnth after the operation, possibly due to the decreasing number of phagocytes at the interface and the increasing amount of bone in the macropores. 相似文献
The long term success of total joint replacement can be limited by fatigue failure of the acrylic cement and the resulting disruption of the bone-cement interface. The incidence of such problems may be diminished by reduction of the fatigue notch factor in the cement, so that stress concentrations are avoided and the fatigue crack initiation time maximized. This study describes a method for numerical shape optimization whereby the finite element method is used to determine an optimal shape for the femoral stem of a hip prosthesis in order to minimize the fatigue notch factor in the cement layer and at interfaces with the bone and stem.
A two-dimensional model of the proximal end of a femur fitted with a total hip prosthesis was used which was equivalent to a simplified three-dimensional axisymmetric model. Software was developed to calculate the fatigue notch factor in the cement along the cement/stem and cement/bone interfaces and in the proximal bone. The fatigue notch factor in the cement at the cement/stem interface was then minimized using the ANSYS finite element program while constraining the fatigue notch factor at the cement/bone interface at or below its initial level and maintaining levels of stress in the proximal bone to prevent stress shielding. The results were compared with those from other optimization studies. 相似文献
By use of scanning electron microscopy (SEM), together with energy dispersive chemical analysis, a study has been made of the comparison of an in vitro method of assessing interface reactions between bone and ceramic implants with the naturally occurring changes seen in the rat ear model. Interface reactions between bone and two ceramic materials were examined following 4 wk in culture and 4 wk implantation. In both cases a gradual chemical change occurred at the calcium silicate surface during the fibrous growth onto the ceramic material. Gradual mineralization of the connective fibres was found at the interface of the calcium silicate material, whereas, in the case of alumina ceramic a connective fibrous bond had formed with no associated chemical change at the ceramic surface. 相似文献
Recording the motor output of the central nervous system from the cervical spinal cord was investigated as a method of generating voluntary command signals, potentially to be used in quadriplegic individuals. Corticospinal volleys evoked by motor cortex stimulation were recorded from the spinal cord surface with multicontact electrodes in anesthetized cats. The multicontact recordings were analyzed for their information-carrying capacity as a neural interface. Neural signals resulting from the stimulation of various points in the motor cortex were considered as symbols of an alphabet that were sent through a discrete information channel. The information capacity of this channel at the thermal noise level of the electrode contacts was calculated. The maximum information rate was 1.57 bits in a trial for a 4-symbol alphabet. The background noise that reduces the information rate to 50% of its maximum theoretical value was defined as the half-bitrate-noise-tolerance (HBR-NoiseTol) and used as a measure of symbol distinguishability. The HBR-NoiseTol for all trials on average was 24 +/- 12%, 18 +/- 10%, and 15 +/- 9% for interfaces with 2-, 3-, and 4-symbol alphabets (n = 11 trials). The average peak-to-peak amplitude of the neural volleys was 13.5 +/- 6.7 microV (n = 11). These results suggest that the corticospinal signals can be recorded with spatial selectivity from the spinal cord surface and thus warrant further investigation of their potential use for a spinal cord-computer interface. 相似文献
AIMS: To describe a new surgical technique for deep stromal anterior lamellar keratoplasty. METHODS: In eye bank eyes and sighted human eyes, aqueous was exchanged by air, to visualise the posterior corneal surface--that is, the "air to endothelium" interface. Through a 5.0 mm scleral incision, a deep stromal pocket was created across the cornea, using the air to endothelium interface as a reference plane for dissection depth. The pocket was filled with viscoelastic, and an anterior corneal lamella was excised. A full thickness donor button was sutured into the recipient bed after stripping its Descemet's membrane. RESULTS: In 25 consecutive human eye bank eyes, a 12% microperforation rate was found. Corneal dissection depth averaged 95.4% (SD 2.7%). Six patient eyes had uneventful surgeries; in a seventh eye, perforation of the lamellar bed occurred. All transplants cleared. Central pachymetry ranged from 0.62 to 0.73 mm. CONCLUSION: With this technique a deep stromal anterior lamellar keratoplasty can be performed with the donor to recipient interface just anterior to the posterior corneal surface. The technique has the advantage that the dissection can be completed in the event of inadvertent microperforation, or that the procedure can be aborted to perform a planned penetrating keratoplasty. 相似文献