Normal blood flow and velocity in the superior sagittal sinus were measured in 30 patients. A fast two-dimensional ungated phase-contrast (PC) pulse sequence was compared with a peripherally gated cine PC technique for velocity and flow quantitation. The same imaging parameters were used for both methods. Measured values for mean velocity and flow obtained with the two methods were compared by using regression analysis and t testing. For blood flow, the correlation coefficient was 0.976. For velocity measurements, r was 0.950. Mean flow was 285 mL/min ± 19 with the ungated PC method and 281 mL/min ± 19 with the cine PC method. The mean velocities measured with the two methods were 12.94 cm/sec ± 1.1 and 13.59 cm/sec ± 1.1, respectively. There was no significant difference (paired t test) between the methods for mean flow or velocity data. This was true even though flow in the superior sagittal sinus is moderately pulsatile, as shown with the cine PC technique. The ungated PC method provided these data in 13 seconds versus 3.5 minutes for the cine PC method. 相似文献
Background. Partial harvesting of the left internal mammary artery (LIMA) is a widespread technique used during minimally invasive coronary operations performed through a left anterior small thoracotomy. The influence of persisting LIMA branches was investigated to evaluate their effect on the blood flow of the left anterior descending artery.
Methods. Thirty patients, 15 with totally (group A) and 15 with partially (group B) harvested LIMAs, were evaluated. All the patients underwent postoperative angiography, during which a flow map of the LIMA was performed. The average peak velocity and the diastolic-to-systolic peak velocity ratio were recorded. The LIMA graft flow pattern was recorded in the proximal and distal thirds of the artery. Intramammary adenosine (12 to 14 μg) was injected and the average peak velocities before and after injection were calculated.
Results. The average peak velocity was similar in both groups in the proximal and distal thirds of the LIMA (25 ± 7 and 26 ± 5 cm/sec, respectively, in group A versus 27 ± 5 and 25 ± 5 cm/sec, respectively in group B; p = NS). The diastolic-to-systolic peak velocity ratio was similar proximally (0.78 ± 0.3 in group A versus 0.69 ± 0.3 cm/s in group B; p = NS), but not distally (1.72 ± 0.1 in group A versus 0.97 ± 0.3 in group B; p < 0.0005). The LIMA graft flow reserve was similar both proximally and distally (2.6 ± 0.6 and 2.5 ± 0.3 cm/s, respectively, in group A versus 2.6 ± 0.5 and 2.6 ± 0.3 cm/s, respectively, in group B; p = NS).
Conclusions. The persistence of LIMA branches does not influence the blood flow of the left anterior descending artery after acute adenosine-induced myocardial hyperemia. If a left anterior small thoracotomy is used in left anterior descending artery direct revascularization, complete LIMA harvesting is not mandatory and depends on the personal preference of the surgeon. 相似文献
The subcellular distribution of the blood group antigen A in the transitional epithelium of the urinary tract and its neoplastic growths was studied using transmission immuno-electronmicroscopy. Sixty-five tissue specimens from 50 blood group A1 patients were processed according to an immunogold procedure which was optimized for preservation of both antigen and ultrastructure. The reactions were stronger in the glycocalyx of the luminal surfaces and at the interdigitating cytoplasmic processes of the cells. In the intracellular compartment the reactions were associated with tubulovesicular membrane-bound structures and with the Golgi complexes. Secretory products, intra- or extra-cellular, were also positive. The greatest variability was noted in the cell surface reactions, which were positive in 88% of normal but only 41% of neoplastic urothelial specimens. An inverse correlation was found between malignant behaviour and cell surface, but not intracellular, reactions. We conclude that, in transitional cell carcinomas, there is a quantitative defect in the processing of substance A which affects predominantly the cell surface component and may involve either the transport-insertion steps, the plasma membrane-associated glycosyltransferases or internalization of blood group antigen A. 相似文献
Perfusion is a crucial physiological parameter for tissue function. To obtain perfusion-weighted images and consequently to measure cerebral blood flow (CBF), a newly developed flow-sensitive alternating inversion recovery (FAIR) technique was used. Dependency of FAIR signal on inversion times (TI) was examined; signal is predominantly located in large vessels at short TI, whereas it is diffused into gray matter areas at longer TI. CBF of gray matter areas in the human brain is 71 ± 15 SD ml/100 g/min (n = 6). In fMRI studies, micro- and macrovessel inflow contributions can be obtained by adjusting TIs. Signal changes in large vessel areas including the scalp were seen during finger opposition at a TI of 0.4 s; however, these were not observed at a longer TI of 1.4 s. To compare with commonly used BOLD and slice selective inversion recovery techniques, FAIR and BOLD images were acquired at the same time during unilateral finger opposition. Generally, activation sites determined by three techniques are consistent. However, activation of some areas can be detected only by FAIR, not by BOLD, suggesting that the oxygen consumption increase couples with the CBF change completely. Relative and absolute CBF changes in the contralateral motor cortex are 53 ± 17% SD (n = 9) and 27 ± 11 SD ml/100 g/min (n = 9), respectively. 相似文献
Summary A rapid and quantitative method for the determination of benzodiazepines using high-performance liquid chromatography (HPLC)
with diode-array detection (DAD) is reported. The drugs were extracted from serum, blood or post-mortem blood using C18 extraction columns. Brotizolam was used as internal standard. Experiments with spiked serum/blood samples resulted in recoveries
between 75% and 94% for all investigated benzodiazepines. Excellent linearity was obtained over the concentration range 5–1500
ng benzodiazepine/ml. The limit of detection was approximately 2 ng/ml. The detection of low therapeutic serum levels of highly
potent benzodiazepines is also possible.
相似文献
Gadolinium-DTPA (diethylenetriaminepentaacetic acid)-cascade-polymer, a potential new blood pool contrast agent for magnetic resonance (MR) imaging, was compared with a known blood pool agent, Gd-DTPA-polylysine, in an animal model. The relative signal intensities of liver, renal cortex, pancreas, and trunk muscle were assessed in 12 pigs between 4 seconds and 120 minutes after injection of a 20 μmol/kg dose of each contrast agent, by using a FLASH (fast low-angle shot) sequence. Except for muscle, all tissues showed visible enhancement after injection of either contrast agent. After injection of Gd-DTPA-polymer, enhancement patterns in the liver, renal cortex, and pancreas were similar to those seen after injection of Gd-DTPA-polylysine. No statistically significant differences in enhancement between the two contrast agents were found at any time point. The authors conclude that the contrast kinetics of Gd-DTPA-cascade-polymer are similar to those of Gd-DTPA-polylysine and that this agent may also be used as a blood pool contrast agent for MR imaging. 相似文献