BackgroundAs the World Health Organization (WHO) currently recommends that children be protected against 11 different pathogens, it is becoming increasingly necessary to administer multiple injectable vaccines during a single immunization visit. In this study we assess Gambian healthcare providers’ and infant caregivers’ attitudes and practices related to the administration of multiple injectable vaccines to a child at a single immunization visit before and after the 2015 introduction of inactivated polio vaccine (IPV). IPV introduction increased the number of injectable vaccines recommended for the 4-month immunization visit from two to three in The Gambia.MethodsWe conducted a cross-sectional questionnaire-based survey before and after the introduction of IPV at 4 months of age in a representative sample of all health facilities providing immunizations in The Gambia. Healthcare providers who administer vaccines at the selected health facilities and caregivers who brought infants for their 4 month immunization visit were surveyed.FindingsPrior to IPV introduction, 9.9% of healthcare providers and 35.7% of infant caregivers expressed concern about a child receiving more than 2 injections in a single visit. Nevertheless, 98.8% and 90.9% of infants received all required vaccinations for the visit before and after IPV introduction, respectively. The only reason why vaccines were not received was vaccine stock-outs. Infant caregivers generally agreed that vaccinators could be trusted to provide accurate information regarding the number of vaccines that a child needed.ConclusionHealthcare providers and infant caregivers in this resource limited setting accepted an increase in the number of injectable vaccines administered at a single visit even though some expressed concerns about the increase. 相似文献
Introduction: Surgery in patients with head and neck cancers is frequently complicated by multiple stages of procedure that includes significant surgical removal of all or part of an organ with cancer, tissue reconstruction, and extensive neck dissection. Postoperative wound infections, termed ‘surgical site infections’ (SSIs) are a significant impediment to head-and-neck cancer surgery and recovery, and need to be addressed.
Areas covered: Approximately 10–45% of patients undergoing head-and-neck cancers surgery develop SSIs. SSIs can lead to delayed wound healing, increased morbidity and mortality as well as costs. Consequently, SSIs need to be avoided where possible, as even the surgery itself impacts on patients’ subsequent activities and their quality of life, which is exacerbated by SSIs. Several risk factors for SSIs need to be considered to reduce future rates, and care is also needed in the selection and duration of antibiotic prophylaxis.
Expert commentary: Head and neck surgeons should give personalized care especially to patients at high risk of SSIs. Such patients include those who have had chemoradiotherapy and need reconstructive surgery, and patients from lower and middle-income countries and from poorer communities in high income countries, who often have high levels of co-morbidity because of resource constraints. 相似文献
Influenza vaccination is considered the most valuable means to prevent and control seasonal influenza infections, which causes various clinical symptoms, ranging from mild cough and fever to even death. Among various influenza vaccine types, the inactivated subunit type is known to provide improved safety with reduced reactogenicity. However, there are some drawbacks associated with inactivated subunit type vaccines, with the main ones being its low immunogenicity and the induction of Th2-biased immune responses. In this study, we investigated the role of a single-stranded RNA (ssRNA) derived from the intergenic region in the internal ribosome entry site of the Cricket paralysis virus as an adjuvant rather than the universal vaccine for a seasonal inactivated subunit influenza vaccine. The ssRNA adjuvant stimulated not only well-balanced cellular (indicated by IgG2a, IFN-γ, IL-2, and TNF-α) and humoral (indicated by IgG1 and IL-4) immune responses but also a mucosal immune response (indicated by IgA), a key protector against respiratory virus infections. It also increases the HI titer, the surrogate marker of influenza vaccine efficacy. Furthermore, ssRNA adjuvant confers cross-protective immune responses against heterologous influenza virus infection while promoting enhanced viral clearance. Moreover, ssRNA adjuvant increases the number of memory CD4+ and CD8+ T cells, which can be expected to induce long-term immune responses. Therefore, this ssRNA-adjuvanted seasonal inactivated subunit influenza vaccine might be the best influenza vaccine generating robust humoral and cellular immune responses and conferring cross-protective and long-term immunity. 相似文献
An important part of fundamental research in catalysis is based on theoretical and modeling foundations which are closely connected with studies of single-crystalline catalyst surfaces. These so-called model catalysts are often prepared in the form of epitaxial thin films, and characterized using advanced material characterization techniques. This concept provides the fundamental understanding and the knowledge base needed to tailor the design of new heterogeneous catalysts with improved catalytic properties. The present contribution is devoted to development of a model catalyst system of CeO2 (ceria) on the Cu(111) substrate. We propose ways to experimentally characterize and control important parameters of the model catalyst—the coverage of the ceria layer, the influence of the Cu substrate, and the density of surface defects on ceria, particularly the density of step edges and the density and the ordering of the oxygen vacancies. The large spectrum of controlled parameters makes ceria on Cu(111) an interesting alternative to a more common model system ceria on Ru(0001) that has served numerous catalysis studies, mainly as a support for metal clusters. 相似文献
The extracellular electrophysiological properties of neurons in the laterodorsal tegmental nucleus (LDT), a major source of cholinergic afferents to the thalamus, were studied in chloral hydrate-anesthetized rats. A combination of antidromic activation from the thalamus and histological verification of recording sites was used to correlate the identity of extracellular recordings in the rat LDT with cholinergic neurons in that region. All neurons antidromically activated by stimulation of the anteroventral thalamus were histologically verified to be within clusters of cholinergic (NADPH-d-positive) cells in the LDT or in the adjacent nucleus locus coeruleus (LC). The thalamically projecting LDT neurons had a homogeneous neurophysiological profile consisting of long duration action potentials (mean = 2.5 ms), slow conduction velocities (mean = 0.78 m/s), and lengthy chronaxie values (mean = 0.725 ms). The appearance and axonal characteristics of these neurons resembled those of noradrenergic LC neurons, but the two populations exhibited substantially different spontaneous activity patterns and sensory responsiveness. These characteristics may be useful in the preliminary identification of putative cholinergic neurons in vivo, and thereby provide a foundation for exploring the neuropharmacology, afferent modulation, sensory responsiveness and behavioral correlates of the brainstem cholinergic system. 相似文献
Two nonlinear pharmacokinetic models were simulated to investigate the relationship between single and multiple dose bioequivalency parameters for drugs such as phenytoin and propranolol which exhibit either saturable elimination kinetics or a capacity limited first pass effect. Mean Tmax, Cmax and area under the plasma-concentration time curve values from 0 to infinity (AUC 0-infinity) were compared after a single and multiple dose(s) of a test or reference drug. The aim was to determine if there were systematic changes in the limits of the single dose confidence interval at steady state that would limit the usefulness of confidence intervals following a single dose in accurately predicting bioavailability following multiple dosing. The 90 per cent confidence interval expressed as a percentage of the reference mean for Tmax, Cmax, and AUC 0-infinity showed model dependent changes from single to multiple dosing in response to the level of data error and changes in absorption. Changes in clearance also seemed to have a marked effect on the observed limits of the single and multiple dose confidence intervals especially for Cmax which showed a characteristic change in the intervals as a function of the clearance ratio. The model used to describe phenytoin had confidence intervals for Cmax and AUC 0-infinity from single to multiple dosing that were similar to that seen for the experimental data. However, the model predictions for Tmax confidence intervals following single and multiple dosing was at variance with the experimental data for formulations A and B. 相似文献
Summary A new modification of microvenous anastomosis, which has increased patency rates while simultaneously decreasing the difficulty of the procedure, is presented in this paper. The primary purpose of this study was to compare the classical and the temporary stent techniques of microvenous anastomosis. Because of problems such as mixing and tangling of strings during insertion and tying of the last four sutures while applying the temporary stent technique, we decided to modify the procedure. The silastic tube was removed through an incision (venotomy), distant from the actual suture line. This modified technique and the other above mentioned techniques were carried out on rat femoral veins. The results indicate that this modification has increased patency rates, shortened the time of anastomosis and facilitated the procedure. 相似文献
The Flinders Sensitive Line (FSL) of rats has been selectively bred to have increased sensitivity to cholinergic agonists. However, these rats exhibit altered responsiveness to a number of noncholinergic agents, such as apomorphine, buspirone and ethanol. This study compared the FSL and control Flinders Resistant Line (FRL) rats in terms of their hyperthermic response to the phencyclidine (PCP) receptor agonist, MK-801 (0.2 mg/kg SC) and their MK-801 binding characteristics. We have found that FSL rats react with a delayed hyperthermia, having a significantly lower hyperthermia for the first 120 min of observation. Thereafter the response does not differ in FSL and FRL rats. Both groups had similar affinities and numbers of [3H]MK-801 binding sites in the hippocampus/cerebral cortex. Pretreatment with scopolamine (1 mg/kg SC) failed to affect MK-801-induced hyperthermia in either line of rats. These findings suggest that selective breeding of FSL rats attenuated the secondary mechanisms involved in the PCP receptor-mediated hyperthermic response. However, by itself cholinergic supersensitivity does not appear to be a major factor in the blunted responsiveness of FSL rats to MK-801. 相似文献
With the dawn of a new millennium, physicians' demands for very thin transvenous leads able to be positioned in nontraditional sites like the Bachmann's bundle, the high and mid-right ventricular septum, and the His bundle have created new and exciting challenges for lead engineers. Bipolar leads can now be as thin and reliable as unipolar leads. Cathode electrodes are very small, porous, and demonstrate high impedance. To optimize stimulation thresholds, steroid-eluting passive- and active-fixation electrodes have become popular for use in the atrium and ventricle. To create thin lead body diameters, new insulation and conductor materials and lead body designs are necessary. Hybrid medical materials having the best features of silicone rubber and polyurethane will allow for reliable insulation. Conductor cables instead of helical coils permit strong thin diameter leads to be designed. Transvenous lead implantation using the traditional stylet may not be possible with thin diameter leads, necessitating the use of sophisticated workstations using steerable catheters to guide these new active-fixation leads to selective sites in the right heart. The pacing lead of the future may be very different from the one used today. Ironically, it will have features and implantation techniques similar to the transvenous leads designed prior to the use of the stylet. We are now approaching full circle in lead development, retracing the footprints of the early implanters of three and a half decades ago. (PACE 2004; 27[Pt. II]:887–893) 相似文献