The aim of this study is to investigate the feasibility of manufacturing thin real-time relative dosimeters for clinical radiotherapy (RT) with potential applications for transmission monitoring in vivo dosimetry and pre-treatment dose verifications. Thin (≈1 μm) layers of a high sensitivity, wide bandgap semiconductor, the inorganic perovskite CsPbCl3, have been grown for the first time by magnetron sputtering on plastic substrates equipped with electrode arrays. Prototype devices have been tested in real-time configuration to evaluate the dose delivered by a 6 MV photon beam from a linear accelerator. Linearity of the charge with the dose has been verified over three order of magnitudes, linearity of the current signal with the dose rate has been also successfully tested in the range 0.5-4.3 Gy/min. The combination of high sensitivity per unit volume and wide bandgap provides high signal-to-noise ratios, up to 70, even at moderate applied voltages. The Schottky diode configuration allows the detector to operate without bias voltage (null bias).The blocking-barrier structure allows to confine the active volume within sub-millimetric sizes, a quite attractive feature in view to increase granularity and achieve the high spatial resolutions required in modern RT techniques. All the above-mentioned features indeed pave the way to a novel generation of flexible, transmission, real time dosimeters for clinical radiotherapy. 相似文献
Central illustration: cumulative major adverse cardiac events (MACE) and bioresorbable vascular scaffold (BVS) thrombosis rates after 1, 2, 3, 4 and 5 years.相似文献
PurposeTo retrospectively evaluate the safety and effectiveness of the Covera stent graft (SG) for the treatment of dysfunctional or thrombosed arteriovenous grafts (AVGs).Materials and MethodsWithin 29 months (February 2016–August 2018), 79 patients underwent Covera SG placement in the authors’ department for the treatment of dysfunctional AVGs. Data were available for 64 patients who underwent 64 procedures, using 64 devices. Minimum follow-up was 6 months, unless reintervention occurred. Mean follow-up was 277 days (6–923 days). Treatment characteristics were 51 cases with venous-graft anastomosis (VGA) stenosis (79.7%), 13 cases of puncture zone stenosis (20.3%), 14 cases of in SG stenosis (21.9%), 8 cases of pseudoaneurysm treatment (12.5%) (1 treatment area might have had more than 1 characteristic). Thirty-six patients presented with thrombosis (56.2%), and 31 of 64 case were de novo treatment areas (48.4%). Primary outcome measurements were technical success and post-intervention primary patency (PIPP) at 6 months, whereas secondary outcome measurements included factors influencing primary outcome.ResultsTechnical success was 100%. Median PIPP was 336 days, and 73.6% of treatment areas were patent at 6 months. There were no significant differences in terms of PIPP when de novo treatment areas were compared with restenotic areas (519 vs. 320 days, respectively; P = .1); patients who presented with versus those who presented without thrombosis (320 vs. 583 days, respectively; P = .07); puncture zone stenosis or elsewhere (329 vs. 686 days, respectively; P = .52); and VGA stenosis or elsewhere (336 vs. 335 days, respectively; P = .9).ConclusionsUse of the Covera SG for AVG treatment was safe and effective in every type of treatment area presented in this retrospective analysis. 相似文献
Summary A new modification of microvenous anastomosis, which has increased patency rates while simultaneously decreasing the difficulty of the procedure, is presented in this paper. The primary purpose of this study was to compare the classical and the temporary stent techniques of microvenous anastomosis. Because of problems such as mixing and tangling of strings during insertion and tying of the last four sutures while applying the temporary stent technique, we decided to modify the procedure. The silastic tube was removed through an incision (venotomy), distant from the actual suture line. This modified technique and the other above mentioned techniques were carried out on rat femoral veins. The results indicate that this modification has increased patency rates, shortened the time of anastomosis and facilitated the procedure. 相似文献