首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   51篇
  免费   2篇
  国内免费   1篇
耳鼻咽喉   1篇
儿科学   2篇
基础医学   7篇
口腔科学   2篇
临床医学   12篇
内科学   4篇
神经病学   3篇
特种医学   3篇
外科学   4篇
综合类   1篇
预防医学   10篇
眼科学   1篇
药学   4篇
  2022年   3篇
  2021年   4篇
  2020年   5篇
  2019年   2篇
  2018年   1篇
  2017年   1篇
  2016年   4篇
  2015年   2篇
  2014年   4篇
  2013年   5篇
  2012年   4篇
  2011年   3篇
  2010年   4篇
  2009年   1篇
  2008年   3篇
  2007年   4篇
  2006年   1篇
  2002年   1篇
  2000年   1篇
  1989年   1篇
排序方式: 共有54条查询结果,搜索用时 15 毫秒
51.
52.
Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect.  相似文献   
53.

Objective:

Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM.

Methods:

This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization.

Results:

Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly.

Conclusions:

The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.  相似文献   
54.
BackgroundFor protection against coronavirus disease 2019 (COVID-19), the Korean government recommended the KF94 mask or that a mask at the same level as the KF94 should be worn when contacting a patient with COVID-19. Furthermore, adequately fitted N95 respirators and KF94 masks are essential. We investigated the fit tests to determine whether healthcare workers had adequate protection with N95 respirators and KF94 masks.MethodsIn this prospective single-center simulation study, five N95 respirators (two made in the USA by 3M and three made in Korea) and six KF94 masks, the Korean standard medical masks, were tested. The fit factor (FF) and leakage rate were evaluated using a two-fit test device. Adequate protection (defined as FF ≥ 100 or leakage rate ≤ 5) rates were compared between N95 respirators and KF94 masks, and between made in Korea and the 3M N95 respirators. For KF94 masks, adequate protection rates were compared before and after ear strap fixation.ResultsOverall, 30 participants were enrolled, and 330 fit tests were performed for FF and leakage rate. Adequate protection rates of all tested N95 respirators and KF94 masks were 22.7% (n = 75) by FF and 20.6% (n = 68) by leakage rate. N95 respirators showed a significantly higher adequate protection rate than KF94 masks for FF (48.7% vs. 1.1%, P < 0.001) and leakage rate (42.0% vs. 2.8%, P < 0.001). Adequate protection rate of 3M-made N95 respirators was significantly higher than that of those made in Korea (83.3% vs. 25.6% in FF, P < 0.001; 73.3% vs. 21.1% in leakage rate, P < 0.001). In KF94 masks, after fixation of ear strap with a hook, adequate protection rate improved significantly (1.1% vs. 12.8% in FF, P < 0.001; 2.8% vs. 11.1%, P < 0.001).ConclusionAlthough adequate protection rate of N95 respirators was higher than that of KF94 masks, N95 respirator protection rate was not optimum. Thus, it is necessary to minimize exposure to risk by selecting an appropriate mask or respirator that adequately fits each person, and by wearing respirators or masks appropriately, before contacting the patients. With their superior protection rate, wearing N95 respirators is recommended instead of KF94 masks, especially when performing aerosol-generating procedures.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号