Purpose: To evaluate the basic characteristics and reproducibility of anterior chamber angle (ACA) measurements determined by anterior‐segment optical coherence tomography (AS‐OCT) in open‐angle and primary angle closure suspect (PACS) patients. Methods: Thirty‐nine open‐angle and 18 PACS patients were imaged for ACA by AS‐OCT. Subjects underwent imaging of the nasal, temporal and inferior ACA under conditions of constant light, and darkness. For analysis, we used three ACA parameters handled by the Visante OCT software: angle opening distance at 500 μm (AOD500), trabecular‐iris space area at 500 μm (TISA500) and angle recess area at 500 μm (ARA500). For determination of inter‐session reproducibility, a single well‐trained operator (D.Y.K.) scanned all patients at two different visits. For determination of inter‐operator variability, a second operator (S.B.P.) acquired another set of images independently. Three sets of images were acquired at least 24 hour apart. Results: All parameters were significantly different when measured both in light and darkness, and in the nasal and temporal quadrants. There were no significant differences between the left and right eyes in the three ACA parameters in all quadrants. The temporal angle was wider than the nasal and inferior angles. All parameters of the nasal, temporal angles had excellent inter‐session and inter‐operator reproducibility [intra‐class correlation coefficient (ICC) 0.796–0.981], but these values were slightly lower for inferior angle measurements (ICC 0.662–0.892) in both open‐angle and PACS groups. Conclusion: AS‐OCT provides quantitative and reproducible assessment of ACA. Reproducibility was lower in the inferior angle compared with the nasal and temporal angles, perhaps because of variable placement of the scleral spur. 相似文献
Magic-angle spinning (MAS) solid-state NMR (SSNMR) techniques have emerged in recent years for solving complete structures of uniformly labeled proteins lacking macroscopic order. Strategies used thus far have relied primarily on semiquantitative distance restraints, analogous to the nuclear Overhauser effect (NOE) routinely used in solution NMR. Here, we present a complementary approach for using relative orientations of molecular fragments, determined from dipolar line shapes. Whereas SSNMR distance restraints typically have an uncertainty of approximately 1 A, the tensor-based experiments report on relative vector (pseudobond) angles with precision of a few degrees. By using 3D techniques of this type, vector angle (VEAN) restraints were determined for the majority of the 56-residue B1 immunoglobulin binding domain of protein G [protein GB1 (a total of 47 HN-HN, 49 HN-HC, and 12 HA-HB restraints)]. By using distance restraints alone in the structure calculations, the overall backbone root-mean-square deviation (bbRMSD) was 1.01 +/- 0.13 A (1.52 +/- 0.12 A for all heavy atoms), which improved to 0.49 +/- 0.05 A (1.19 +/- 0.07 A) on the addition of empirical chemical shift [torsion angle likelihood obtained from shift and sequence similarity (TALOS)] restraints. VEAN restraints further improved the ensemble to 0.31 +/- 0.06 A bbRMSD (1.06 +/- 0.07 A); relative to the structure with distances alone, most of the improvement remained (bbRMSD 0.64 +/- 0.09 A; 1.29 +/- 0.07 A) when TALOS restraints were removed before refinement. These results represent significant progress toward atomic-resolution protein structure determination by SSNMR, capabilities that can be applied to a large range of membrane proteins and fibrils, which are often not amenable to solution NMR or x-ray crystallography. 相似文献
BACKGROUND: This study was designed to confirm our previous findings that nonalcoholic offspring from families with alcohol-dependent individuals have greater hypothalamic-pituitary-adrenal axis activation induced by opioid blockade compared with nonalcoholic subjects without a family history of alcohol dependence. METHODS: Sixty-four nonalcoholic subjects aged 18 to 25 years were enrolled in the protocol. Twenty-seven subjects were offspring from families with alcohol dependence and were designated as family history-positive subjects (FHP). Thirty-seven subjects were biological offspring of non-alcohol-dependent parents and were designated as family history-negative subjects (FHN). Subjects received naloxone hydrochloride (0, 50, 125, 375, and 500 microg/kg) in double-blind, randomized order; adrenocorticotropin (ACTH) and cortisol were monitored over 120 min. RESULTS: No hormone differences at baseline or during placebo administration were identified between FHP and FHN subjects. FHP subjects had greater ACTH and cortisol response to opioid receptor blockade induced by naloxone hydrochloride compared with FHN subjects. CONCLUSIONS: These observations confirm previous findings that differences in ACTH and cortisol dynamics between FHP and FHN subjects can be unmasked by opioid receptor blockade. 相似文献
Background: Bioelectrical impedance analysis (BIA) is an inexpensive, non-invasive and fast method to assess body composition. Little is known of the interaction between anti IL 12/23 treatment and body composition. The aim of this study was to evaluate 6- and 12-month changes in body weight, Body Mass Index (BMI) and body composition assessed by BIA in psoriatic patients treated with anti-IL-12/23.
Research design and methods: Demographic and clinical data were collected for each enrolled patient. Physical examination, anthropometric assessment, Psoriasis Area and Severity Index (PASI) assessment and body composition by BIA (single-frequency 50 kHz), were assessed at baseline and at 6 and 12 months of treatment.
Results: A significant decrease in body weight, compared to baseline, in BMI, Fat Mass at month 6 and a significant increase at month 12 for body cellular mass (BCM) and Phase Angle (PhA) were observed. In addition, a significant increase was found for intracellular water.
Conclusion: At baseline, psoriatic patients showed a lower BCM and a lower mean PhA score. During ustekinumab treatment, the mean PhA and BCM scores increased with an improvement in psoriatic disease. Thus, ustekinumab can be an effective drug for improving not only psoriasis but also the general clinical status of patients. 相似文献
To quantify the effects of initial hip angle and angular hip velocity settings of a lower-limb wearable robotic exoskeleton (WRE) on the balance control and mechanical energy requirements in patients with paraplegic spinal cord injuries (SCIs) during WRE-assisted sit-to-stand (STS).
Design
Observational, cross-sectional study.
Setting
A university hospital gait laboratory with an 8-camera motion analysis system, 3 forceplates, a pair of instrumented crutches, and a WRE.
Participants
Patients (N=12) with paraplegic SCI.
Interventions
Not applicable.
Main Outcome Measures
The inclination angle (IA) of the body’s center of mass (COM) relative to the center of pressure (COP), and the rate of change of IA (RCIA) for balance control, and the mechanical energy and forward COM momentum before and after seat-off for energetics during WRE-assisted STS were compared between conditions with 2 initial hip angles (105° and 115°) and 3 initial hip angular velocities (800, 1000, 1200 rpm).
Results
No interactions between the main factors (ie, initial hip angle vs angular velocity) were found for any of the calculated variables. Greater initial hip angle helped the patients with SCI move the body forward with increased COM momentum but reduced RCIA (P<.05). With increasing initial angular hip velocity, the IA and RCIA after seat-off (P<.05) increased linearly while total mechanical energy reduced linearly (P<.05).
Conclusions
The current results suggest that a greater initial hip angle with smaller initial angular velocity may provide a favorable compromise between momentum transfer and balance of the body for people with SCI during WRE-assisted STS. The current data will be helpful for improving the design and clinical use of the WRE. 相似文献
Children with slipped capital femoral epiphysis (SCFE) are often seen by an array of medical professionals prior to diagnosis. Patients with mild slips, slips with knee pain, or bilateral slips can occasionally present a diagnostic challenge that increases the risk of a delay in diagnosis and associated complications.
Objectives
This study introduces a new radiographic parameter, which we refer to as the S-sign, and analyzes its diagnostic utility on a frog-leg lateral radiograph.
Methods
Twenty observers reviewed the radiographs from 35 patients with SCFE using Klein's line on anteroposterior pelvis radiographs and the S-sign on frog-leg lateral radiographs to diagnose an SCFE. Analysis included diagnostic outcomes and intraobserver and interobserver reliability.
Results
The S-sign was more accurate at identifying an SCFE compared with Klein's line (92.4% vs. 79.2%, respectively). Sensitivity and specificity was greater for the S-sign compared with Klein's line (89.0% and 95.2% vs. 68.3% and 89.0%, respectively). A combination of the S-sign and Klein's line yielded a sensitivity of 96.5% and a specificity of 85.0%. The combination of tests was more diagnostic for an SCFE, compared with using the Klein's line, which was statistically significant (p < 0.001).
Conclusions
With increased awareness of the S-sign and a usage of the combined test, clinicians can more reliably and accurately diagnose an SCFE. Clinicians are more likely to diagnose an SCFE using the combined test, compared with solely relying on Klein's line, which we found to be statistically significant. 相似文献