首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   118篇
  免费   23篇
基础医学   8篇
临床医学   3篇
特种医学   129篇
外科学   1篇
  2023年   3篇
  2020年   2篇
  2019年   7篇
  2018年   1篇
  2017年   5篇
  2016年   10篇
  2015年   5篇
  2014年   11篇
  2013年   5篇
  2012年   9篇
  2011年   10篇
  2010年   12篇
  2009年   5篇
  2008年   22篇
  2007年   8篇
  2006年   15篇
  2005年   6篇
  2004年   4篇
  2003年   1篇
排序方式: 共有141条查询结果,搜索用时 31 毫秒
101.

Purpose:

To compare generalized autocalibrating partially parallel acquisitions (GRAPPA), modified sensitivity encoding (mSENSE), and SENSE in phase‐contrast magnetic resonance imaging (PC‐MRI) applications.

Materials and Methods:

Aliasing of the torso can occur in PC‐MRI applications. If the data are further undersampled for parallel imaging, SENSE can be problematic in correctly unaliasing signals due to coil sensitivity maps that do not match that of the aliased volume. Here, a method for estimating coil sensitivities in flow applications is described. Normal volunteers (n = 5) were scanned on a 1.5 T MRI scanner and underwent PC‐MRI scans using GRAPPA, mSENSE, SENSE, and conventional PC‐MRI acquisitions. Peak velocity and flow through the aorta and pulmonary artery were evaluated.

Results:

Bland–Altman statistics for flow in the aorta and pulmonary artery acquired with mSENSE and GRAPPA methods (R = 2 and R = 3 cases) have comparable mean differences to flow acquired with conventional PC‐MRI. GRAPPA and mSENSE PC‐MRI have more robust measurements than SENSE when there is aliasing artifact caused by insufficient coil sensitivity maps. For peak velocity, there are no considerable differences among the mSENSE, GRAPPA, and SENSE reconstructions and are comparable to conventional PC‐MRI.

Conclusion:

Flow measurements of images reconstructed with autocalibration techniques have comparable agreement with conventional PC‐MRI and provide robust measurements in the presence of wraparound. J. Magn. Reson. Imaging 2010;31:1004–1014. ©2010 Wiley‐Liss, Inc.  相似文献   
102.
Phase contrast MRI with multidirectional velocity encoding requires multiple acquisitions of the same k‐space lines to encode the underlying velocities, which can considerably lengthen the total scan time. To reduce scan time, parallel imaging is often applied. In dynamic phase contrast MRI using standard generalized autocalibrating partially parallel acquisitions (GRAPPA), several central k‐spaces for autocalibration of the reconstruction (autocalibrating signal lines (ACS)) are typically acquired, separately for each velocity direction and each cardiac timeframe, for calculating the reconstruction weights. To further accelerate data acquisition, we developed two methods, which calculated weights with a substantially reduced number of ACSl lines. The effects on image quality and flow quantification were compared to fully sampled data, standard GRAPPA, and time‐interleaved sampling scheme in combination with generalized autocalibrating partially parallel acquisitions (TGRAPPA). The results show that the two proposed methods can clearly improve scan efficiency while maintaining image quality and accuracy of measured flow or myocardial tissue velocities. Compared to TGRAPPA, the proposed methods were more accurate in evaluating flow velocity. In conclusion, the proposed reconstruction strategies are promising for dynamic multidirectionally encoded acquisitions and can easily be implemented using the standard GRAPPA reconstruction algorithm. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   
103.
In MRI applications where short acquisition time is necessary, the increase of acquisition speed is often at the expense of image resolution and SNR. In such cases, the newly developed parallel acquisition techniques could provide images without mentioned limitations and in reasonably shortened measurement time. A newly designed eight-channel head coil array (i-PAT coil) allowing for parallel acquisition of independently reconstructed images (GRAPPA mode) has been tested for its applicability in neuroradiology. Image homogeneity was tested in standard phantom and healthy volunteers. BOLD signal changes were studied in a group of six volunteers using finger tapping stimulation. Phantom studies revealed an important drop of signal even after the use of a normalization filter in the center of the image and an important increase of artifact power with reduction of measurement time strongly depending on the combination of acceleration parameters. The additional application of a parallel acquisition technique such as GRAPPA decreases measurement time in the range of about 30%, but further reduction is often possible only at the expense of SNR. This technique performs best in conditions in which imaging speed is important, such as CE MRA, but time resolution still does not allow the acquisition of angiograms separating the arterial and venous phase. Significantly larger areas of BOLD activation were found using the i-PAT coil compared to the standard head coil. Being an eight-channel surface coil array, peripheral cortical structures profit from high SNR as high-resolution imaging of small cortical dysplasias and functional activation of cortical areas imaged by BOLD contrast. In BOLD contrast imaging, susceptibility artifacts are reduced, but only if an appropriate combination of acceleration parameters is used.  相似文献   
104.
105.
The purpose of this study was to explore how to optimally undersample and reconstruct time‐resolved 3D data using a k‐t‐space‐based GRAPPA technique. The performance of different reconstruction strategies was evaluated using data sets with different ratios of phase (Ny) and partition (Nz) encoding lines (Ny × Nz = 64–128 × 40–64) acquired in a moving phantom. Image reconstruction was performed for different kernel configurations and different reduction factors (R = 5, 6, 8, and 10) and was evaluated using regional error quantification and SNR analysis. To analyze the temporal fidelity of the different kernel configurations in vivo, time‐resolved 3D phase contrast data were acquired in the thoracic aorta of two healthy volunteers. Results demonstrated that kernel configurations with a small kernel extension yielded superior results especially for more asymmetric data matrices as typically used in clinical applications. The application of k‐t‐GRAPPA to in vivo data demonstrated the feasibility of undersampling of time‐resolved 3D phase contrast data set with a nominal reduction factors of up to Rnet = 8, while maintaining the temporal fidelity of the measured velocity field. Extended GRAPPA‐based parallel imaging with optimized multidimensional reconstruction kernels has the potential to substantially accelerate data acquisitions in time‐resolved 3D MRI. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.  相似文献   
106.
107.
108.
Accelerated parallel MRI has advantage in imaging speed, and its image quality has been improved continuously in recent years. This paper introduces a two‐dimensional infinite impulse response model of inverse filter to replace the finite impulse response model currently used in generalized autocalibrating partially parallel acquisitions class image reconstruction methods. The infinite impulse response model better characterizes the correlation of k‐space data points and better approximates the perfect inversion of parallel imaging process, resulting in a novel generalized image reconstruction method for accelerated parallel MRI. This k‐space‐based reconstruction method includes the conventional generalized autocalibrating partially parallel acquisitions class methods as special cases and has a new infinite impulse response data estimation mechanism for effective improvement of image quality. The experiments on in vivo MRI data show that the proposed method significantly reduces reconstruction errors compared with the conventional two‐dimensional generalized autocalibrating partially parallel acquisitions method, particularly at the high acceleration rates. Magn Reson Med, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   
109.
110.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号