Four patients, who received epidural blood patch to treat postdural puncture headache, were examined with computed tomography in order to demonstrate the distribution of the injected blood. Blood alone could not be identified, but adding 2 ml contrast agent Iohexol 180 mg J/ ml (Omnipaque®, Nycomed Imaging) to 18 ml blood gave an excellent demonstration of the distribution of the blood in the epidural space, both cranio-caudally (7–14 segments) and spatially in relation to the epidural septae. The blood-contrast media had a strong affinity to the dural sac. There was no support of the spacefilling effect of blood patch. 相似文献
Study Objective: To test the hypothesis that slow administration of local anesthetic into the epidural space by gravity flow reduces the incidence of signs and symptoms of unintended injection.
Design: Prospective, randomized study.
Setting: Teaching hospital.
Patients: 600 ASA physical status I and II parturients scheduled for labor and delivery or elective cesarean section.
Interventions: After identification of the epidural space with pulsations of an air-fluid column, parturients for vaginal delivery (n = 380) were randomized to receive a test dose of 3 ml 3% 2-chloroprocaine with epinephrine 20 μg, two doses of 7 ml bupivacaine 0.03 % with sufentanil 1 μg/ml and epinephrine 2 μg/ml by either gravity flow (Group 1) given over 30 seconds or by bolus injection (Group 2) given over 5 seconds through the epidural needle; parturients for Cesarean delivery (n = 220) were randomized to receive a test dose and two doses of 6 ml lidocaine 2 % with sufentanil 1 μg/ml and epinephrine 2 μg/ml by either gravity flow or by bolus injection through the epidural needle. Changes in maternal heart rate (HR) and blood pressure, signs of intravascular injection, and adverse effects of epidural bupivacaine-sufentanil were recorded after each dose.
Measurements and Main Results: Gravity flow administration (Group 1) was associated with a smaller increase in mean maternal HR (p < 0.001), less hypotension (p < 0.01), sedation (p < 0.01), nausea (p = 0.01), and segmental spread (p < 0.0001) than were corresponding doses given by traditional bolus injection (Group 1) for vaginal or Cesarean deliveries. The incidence of systemic toxicity was zero of 300 (0%) with gravity flow and 4 of 300 (1.3%) by bolus injection, p = 0.12, Fisher's exact test. No patient in either group had an accidental intrathecal injection.
Conclusion: Gravity flow administration of local anesthetic-opioid solution during epidural block for obstetrics was associated with fewer signs of systemic drug absorption and cardiovascular perturbations than was the traditional bolus injection. This study supports the current opinion that slow administration of local anesthetic during epidural black contributes to fewer adverse events. 相似文献
This study attempts to demonstrate the existence of allergic contact dermatitis from grass, and to develop a patch test series to screen patients with grass intolerance. 6 common grass species from lawns and military training areas were collected. Solvent extracts of polar. non-polar and volatile fractions were prepared and used for patch testing in 20 control subjects and 46 patients with a history of grass intolerance. The 20 control had negative responses to patch testing. 5 out of 46 patients had positive patch tests to Axonopus compressus (carpet grass). Ischaenmum muticum (sea-shore centipede grass). Imperata evlindrica (lalang). Panicum maximum (Guinea grass) and Pennisetum purpureum (elephant grass). Reactions to the non-polar fraction for all 5 species were noted. This study demonstrates the existence of allergic contact dermatitis from various common species of grass. In our series, this is seen in 11% of those with a history of grass intolerance. 相似文献
A 62-year-old woman with diabetic triopathy developed widespread erythematous macules, numerous pustules, and a high fever after she underwent electric coagulation for vitreous hemorrhage. She was administered several drugs at that time. After discontinuation of the drugs, the eruption disappeared, and the fever returned to normal within two weeks. A positive patch test with isepamicin sulfate highly suggested that the symptoms described above were due to drug allergy. Cadralazine, which was positive in the drug lymphocyte stimulation test (DLST), could not be excluded from the causative drugs. A false-positive DLST with ofloxacin was confirmed by an accidental challenge test. To our knowledge, this is the first report of acute generalized exanthematous pustulosis due to isepamicin sulfate and/or cadralazine. 相似文献
Objective. Tympanic temperature can be obtained instantaneously using an infrared emission detection (IRED) thermometer. Its accuracy has been documented in a variety of clinical settings, but its performance at low body temperatures is still unknown. In this study we evaluated its performance during coronary artery revascularization surgery in which mild hypothermic cardiopulmonary bypass (CPB) was used. Methods. Thirty adult patients undergoing coronary artery bypass graft surgery were enrolled in the study. Tympanic temperature obtained using IRED thermometry (Tt1) was compared with core temperatures from the esophagus (Te), and venous blood of CPB (Tv) before, during, and after CPB. We also measured tympanic temperature using a thermocouple probe (Tt2) in 16 of the 30 patients in order to study the agreement between the two methods. Values for correlation coefficients and limits of agreement were computed to assess the degree of agreement among the temperatures obtained. Results. The highest agreement with Tv during CPB was obtained from Tt1 (r = 0.94, 0.41 ± 1.73, limits of agreement) and from Te (0.91, 0.36 ± 2.46). Tt1 also showed good agreement with Tt2 during surgery. Conclusions. Infrared tympanic thermometry is a reliable, alternative method to measure tympanic temperature and may be useful to assess core temperature in both normothermic and mild hypothermic conditions. 相似文献
Use of the optimum finishing technique for an amalgam restoration may enhance the marginal integrity of the restoration and discourage its unnecessary early replacement. Two hundred and twenty-eight high copper amalgam restorations in 56 patients were evaluated, using clinical assessment criteria, up to three years after placement. Each patient had received at least one carved-only amalgam, at least one immediately finished restoration, and at least one amalgam that was polished at a subsequent appointment. Regardless of the finishing technique, the restorations exhibited similar marginal integrity up to three years after placement. Polished restorations were found to have substantially superior surface texture and less likelihood of surface discoloration. No evidence was found to support the use of immediate finishing techniques. The clinical significance of these findings, with respect to the need to polish amalgam restorations, is discussed. 相似文献