Objective: To examine (i) the associations between physical activity dimensions, cardiorespiratory fitness and body composition and, (ii) the associations between physical activity dimensions, cardiorespiratory fitness, body composition and biomarkers of cardiometabolic health in persons with spinal cord injury (SCI).
Methods: A cross-sectional prospective cohort study with 7-day follow-up was conducted. Body composition, cardiorespiratory fitness and biomarkers of cardiometabolic health were measured in thirty-three participants with SCI (> 1 year post injury). Physical activity dimensions were objectively assessed over 7-days.
Results: Activity energy expenditure (r =.43), physical activity level (r =.39), and moderate-to-vigorous physical activity (MVPA) (r =.48) were significantly (P < 0.001) associated with absolute (L/min) peak oxygen uptake (?O2 peak). ?O2 peak was significantly higher in persons performing ≥150 MVPA minutes/week compared to <40 minutes/week (P?=?0.003). Individual physical activity dimensions were not significantly associated with biomarkers of cardiometabolic health. However, body composition characteristics (BMI, waist and hip circumference) showed significant (P < 0.04), moderate (r >.30) associations with parameters of metabolic regulation, lipid profiles and inflammatory biomarkers. Relative ?O2 peak (ml/kg/min) was moderately associated with only insulin sensitivity (r?=?0.37, P?=?0.03).
Conclusions: Physical activity dimensions are associated with cardiorespiratory fitness; however, stronger and more consistent associations suggest that poor cardiometabolic health is associated with higher body fat content. Given these findings, the regulation of energy balance should be an important consideration for researchers and clinicians looking to improve cardiometabolic health in persons with SCI. 相似文献
Robotic approaches have been steadily replacing laparoscopic approaches in metabolic and bariatric surgeries (MBS); however, their superiority has not been rigorously evaluated. The main goal of the study was to evaluate the 5-year utilization trends of robotic MBS and to compare to laparoscopic outcomes.
Methods
Retrospective analysis of 2015–2019 MBSAQIP data. Kruskal-Wallis test/Wilcoxon and Fisher’s exact/chi-square were used to compare continuous and categorical variables, respectively. Generalized linear models were used to compare surgery outcomes.
Results
The use of robotic MBS increased from 6.2% in 2015 to 13.5% in 2019 (N= 775,258). Robotic MBS patients had significantly higher age, BMI, and likelihood of 12 diseases compared to laparoscopic patients. After adjustment, robotic MBS patients showed higher 30-day interventions and 30-day readmissions alongside longer surgery time (26–38 min).
Conclusion
Robotic MBS shows higher intervention and readmission even after controlling for cofounding variables.
Chronic transplant dysfunction is a complex dynamic pathogenic process. Clinically, a decrease in glomerular filtration rate (GFR) becomes apparent leading to chronic renal insufficiency and dialysis or death from cardiovascular events. Chronic transplant dysfunction can develop into a chronic alIograft nephropathy (CAN) as a specific entity with dynamic progression. CAN includes a collection of immunologic and non-immunologic factors, rejection, ischemia time, donor and recipient characteristics and toxicity of calcineurin inhibitors. Despite improvements in immunosuppression, the long-range prognosis of renal allografts has not improved. Whether modern immunosuppressive concepts with reduction or avoidance of calcineurin inhibitors and a therapy based on antimetabolites, such as mycophenolate or mTOR-inhibitors could lead to a prolongation of transplant survival, remains to be seen. 相似文献
We report the case of a littoral‐cell angioma of the spleen, a recently described benign vascular tumour, whose imaging and pathological characteristics have been discussed only by a few authors. The diagnosis was made after elective splenectomy. The CT images, scintigraphy and histological specimens are presented, and differential diagnoses discussed. 相似文献
Multi-day signals, generally with duration of 2-10 days, are a prominent temporal variation type of radon (Rn) in geogas in the unsaturated zone. Rare multi-day Rn signals have been found which are characterized by: (a) a declining limb lasting up to 10 days which conforms to the radioactive decay of Rn, (b) recurs at the same location and (c) is recorded in diverse situations-volcanic and seismogenic. It suggested that a Rn blob is injected at a lower level on a steady upward flow of geogas whereby the rise and final fall of the signal are attributed to the edges of the blob while the central Rn-decay segment records the passing of the decaying blob itself. Rn-decay signals are a small subset of multi-day Rn signals which are considered as highly irregular and unusable for the understanding of geophysical processes. In difference, it is concluded that multi-day Rn signals are probably proxies of subtle geodynamic processes at upper crustal levels and are therefore significant for studying such processes. 相似文献
SPECT with 99mTc-labeled agents is better able to detect viability after nitrate administration. Nitrates induce vasodilation and may increase blood flow to severely hypoperfused but viable myocardium, thereby enhancing tracer delivery and improving the detection of viability. Quantitative data on the changes in blood flow are lacking in SPECT but can be provided by PET. The aim of the present study was to use PET to evaluate whether nitrate administration increases blood flow to chronically dysfunctional but viable myocardium. METHODS: 13N-Ammonia PET was used to quantitatively assess blood flow, and 18F-FDG PET was used as the gold standard to detect viable myocardium. Twenty-five patients with chronic ischemic left ventricular dysfunction underwent 13N-ammonia PET at rest and after nitrate administration. RESULTS: A significant increase in nitrate-enhanced blood flow was observed in viable segments (from 0.55 +/- 0.15 to 0.68 +/- 0.24 mL/min/g, P < 0.05). No statistically significant change in blood flow was observed in nonviable segments (0.60 +/- 0.20 vs. 0.55 +/- 0.18 mL/min/g). A ratio of at least 1.1 for nitrate-enhanced flow to resting flow allowed optimal detection of viable myocardium, yielding a sensitivity of 82% with a specificity of 100%. CONCLUSION: 13N-Ammonia PET showed a significant increase in nitrate-enhanced blood flow in viable myocardium, whereas blood flow remained unchanged after nitrate administration in nonviable myocardium. Nitrate use during myocardial perfusion imaging will lead to improved assessment of myocardial viability. 相似文献
BACKGROUND AND PURPOSE: There is concern about the increase of radiation-induced malignancies with the application of modern radiation treatment techniques such as intensity-modulated radiotherapy (IMRT) and proton radiotherapy. Therefore, X-ray scatter and neutron radiation as well as the impact of the primary dose distribution on secondary cancer incidence are analyzed. MATERIAL AND METHODS: The organ equivalent dose (OED) concept with a linear-exponential and a plateau dose-response curve was applied to dose distributions of 30 patients who received radiation therapy of prostate cancer. Three-dimensional conformal radiotherapy was used in eleven patients, another eleven patients received IMRT with 6-MV photons, and eight patients were treated with spot-scanned protons. The treatment plans were recalculated with 15-MV and 18-MV photons. Secondary cancer risk was estimated based on the OED for the different treatment techniques. RESULTS: A modest increase of 15% radiation-induced cancer results from IMRT using low energies (6 MV), compared to conventional four-field planning with 15-MV photons (plateau dose-response: 1%). The probability to develop a secondary cancer increases with IMRT of higher energies by 20% and 60% for 15 MV and 18 MV, respectively (plateau dose-response: 2% and 30%). The use of spot-scanned protons can reduce secondary cancer incidence as much as 50% (independent of dose-response). CONCLUSION: By including the primary dose distribution into the analysis of radiation-induced cancer incidence, the resulting increase in risk for secondary cancer using modern treatment techniques such as IMRT is not as dramatic as expected from earlier studies. By using 6-MV photons, only a moderate risk increase is expected. Spot-scanned protons are the treatment of choice in regard to secondary cancer incidence. 相似文献
Conclusion Several quality-control measures take place before (patient and camera preparation) and during SPECT acquisition to achieve
high-quality images. Not uncommonly, technologists and physicians are left with suboptimal images that have to be addressed
to reach the “right answer” for patient diagnosis and hence management. In many cases patients may be reimaged, especially
if the problem is detected early, but in other cases either the patient has left the nuclear laboratory or there is an inevitable
problem that, even with reimaging, will not be resolved. In these situations the technologist and physician have to seek the
available techniques to obtain the best images possible. These resources are discussed in this issue as an aid in quality
control to obtain the best possible images. 相似文献