1. To investigate Genkwa Flos hepatotoxicity, a cell metabolomics strategy combined with serum pharmacology was performed on human HL-7702 liver cells in this study.
2. Firstly, cell viability and biochemical indicators were determined and the cell morphology was observed to confirm the cell injury and develop a cell hepatotoxicity model. Then, with the help of cell metabolomics based on UPLC-MS, the Genkwa Flos group samples were completely separated from the blank group samples in the score plots and seven upregulated as well as two down-regulated putative biomarkers in the loading plot were identified and confirmed. Besides, two signal molecules and four enzymes involved in biosynthesis pathway of lysophosphatidylcholine and the sphingosine kinase/sphingosine-1-phosphate pathway were determined to investigate the relationship between Genkwa Flos hepatotoxicity and these two classic pathways. Finally, the metabolic pathways related to specific biomarkers and two classic metabolic pathways were analyzed to explain the possible mechanism of Genkwa Flos hepatotoxicity.
3. Based on the results, lipid peroxidation and oxidative stress, phospholipase A2/lysophosphatidylcholine pathway, the disturbance of sphingosine-1-phosphate metabolic profile centered on sphingosine kinase/sphingosine-1-phosphate pathway and fatty acid metabolism might be critical participators in the progression of liver injury induced by Genkwa Flos. 相似文献
Objective: To report a case of labour induction during extracorporeal membrane oxygenation (ECMO) support in a patient with acute respiratory distress syndrome (ARDS) caused by influenza and review of the literature.
Methods: Case report and the literature search of all English articles on delivery while on ECMO in patients with ARDS caused by influenza.
Results: A 25-year-old pregnant woman was initiated with ECMO due to severe ARDS caused by influenza A (H1N1) virus. When the patient had symptoms of colporrhagia and uterine contractions, the medical team decided to start labour induction while on ECMO. There were in total five case reports identified. Maternal oxygenation was improved after delivery and ECMO was successfully discontinued.
Conclusions: Maternal oxygenation was improved after delivery, which may be beneficial to reduce the duration of ECMO. Caesarean section (CS) may be the most used mode and labour induction could be another option. The procedure should be performed by an experienced ECMO team, cooperating with the obstetrician, anaesthesiologist, and ICU doctors. 相似文献
Prolonged survival of pancreatic islet allografts implanted in diabetic BB rats was achieved by encapsulation of individual islets in a protective biocompatible alginate-polylysine-alginate membrane without immunosuppression. Intraperitoneal transplantation of the encapsulated islets reversed the diabetic state of the recipients within 3 days and maintained normoglycemia for 190 days. Normal body weight and urine volume were maintained during this period, and no cataracts were detected in the transplant recipients. In contrast, control rats receiving transplants of unencapsulated islets experienced normoglycemia for less than 2 wk. These results demonstrated that microencapsulation can protect allografted islets from both graft rejection and autoimmune destruction without immunosuppression in an animal model that mimics human insulin-dependent diabetes. 相似文献
OBJECTIVES: Dental lasers have been used for uncovering submerged implants as well as decontaminating implant surfaces when treating peri-implantitis. The objective of this study was to compare the possible alterations of the smooth surface and resorbable blast material (RBM) surface implants after using NdYAG and CO(2) lasers at various energies. MATERIALS AND METHODS: Ten smooth surface implants and 10 RBM surface implants were used. Two smooth surface implants and 2 RBM surface implants served as a control group that was not lased. The remaining implants were treated using NdYAG and CO(2) lasers. The surface of each implant was treated for 10 seconds on the second and third threads. The smooth surface implants (group 1) were treated using a pulsed contact NdYAG laser at power settings of 1, 2, 3.5, and 5 W, which are commonly used for soft tissue surgery; the corresponding energy and frequency were 50 mJ and 20 Hz, 100 mJ and 20 Hz, 350 mJ and 10 Hz, and 250 mJ and 20 Hz, respectively. The group 2 RBM implants were treated using a pulsed contact NdYAG laser. The group 3 smooth surface implants were treated using a pulsed wave non-contact CO(2) laser at 1, 2, 3.5, and 5 W, and the group 4 RBM implants were treated using a pulsed wave non-contact CO(2) laser. Data were analyzed using scanning electron microscopy. RESULTS: The control surface was very regular and smooth. After NdYAG laser treatment, the implant surface showed alterations of all the surfaces. The amount of damage was proportional to the power. A remarkable finding was the similarity of the lased areas on the smooth and RBM surfaces. CO(2) laser at power settings of 1.0 or 2.0 W did not alter the implant surface, regardless of implant type. At settings of 3.5 and 5 W, there was destruction of the micromachined groove and gas formation. CONCLUSION: This study supports that CO(2) laser treatment appears more useful than NdYAG laser treatment and CO(2) laser does not damage titanium implant surface, which should be of value when uncovering submerged implants and treating peri-implantitis. 相似文献
Many studies have recently reported on laparoscopic liver resection, although its development has been slow compared to laparoscopy in other fields. The indications for the location of laparoscopic liver resection have previously been limited to easily accessible lesions. Performing laparoscopic liver resection in the posterior and superior parts of the liver has been considered difficult due to inadequate exposure, the poor operative field and the difficulty with parenchymal dissection. Flexible endoscopy, high definition imaging and various kinds of equipment for parenchymal transection have been introduced for clinical use. In addition, much experience with this procedure has been accumulated at many centers. Accordingly, there are an increasing number of reports on laparoscopic liver resection in difficult locations. At our institution, the location of the tumor is no longer a limitation to laparoscopic liver resection. However, for safer laparoscopic liver resection, the patient positioning and trocar placement should be individualized according to the tumor location. The type of resection also may depend on the remaining liver’s functional capacity. We describe here the technical considerations for performing laparoscopic liver resection, including the technical considerations for performing laparoscopic liver resection for lesions located in the postero-superior segments of the liver. 相似文献