首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   97篇
  免费   0篇
儿科学   18篇
基础医学   7篇
临床医学   8篇
内科学   17篇
神经病学   4篇
特种医学   21篇
外科学   11篇
预防医学   6篇
药学   3篇
肿瘤学   2篇
  2021年   2篇
  2020年   3篇
  2019年   2篇
  2017年   2篇
  2016年   2篇
  2015年   3篇
  2013年   6篇
  2012年   9篇
  2011年   10篇
  2009年   1篇
  2008年   9篇
  2007年   13篇
  2006年   5篇
  2005年   11篇
  2004年   6篇
  2003年   4篇
  2002年   7篇
  2000年   1篇
  1999年   1篇
排序方式: 共有97条查询结果,搜索用时 15 毫秒
31.
X-ray mammography is routinely used in national screening programmes and as a clinical diagnostic tool. Magnetic Resonance Imaging (MRI) is commonly used as a complementary modality, providing functional information about the breast and a 3D image that can overcome ambiguities caused by the superimposition of fibro-glandular structures associated with X-ray imaging. Relating findings between these modalities is a challenging task however, due to the different imaging processes involved and the large deformation that the breast undergoes. In this work we present a registration method to determine spatial correspondence between pairs of MR and X-ray images of the breast, that is targeted for clinical use. We propose a generic registration framework which incorporates a volume-preserving affine transformation model and validate its performance using routinely acquired clinical data. Experiments on simulated mammograms from 8 volunteers produced a mean registration error of 3.8±1.6mm for a mean of 12 manually identified landmarks per volume. When validated using 57 lesions identified on routine clinical CC and MLO mammograms (n=113 registration tasks) from 49 subjects the median registration error was 13.1mm. When applied to the registration of an MR image to CC and MLO mammograms of a patient with a localisation clip, the mean error was 8.9mm. The results indicate that an intensity based registration algorithm, using a relatively simple transformation model, can provide radiologists with a clinically useful tool for breast cancer diagnosis.  相似文献   
32.
33.

Background

Sepsis is associated with an increased production of oxidant species and a decrease in endogenous antioxidant defenses. Mortality is high, especially when endotoxins are involved, e.g., in infants with Gram-negative sepsis. Yet, chronic as well as acute unconjugated hyperbilirubinemia has been shown to protect against endotoxin-induced shock in vivo in rats and in mice. We hypothesized that hyperbilirubinemia in infants with Gram-negative sepsis improves survival and/or mitigates the inflammatory response.

Objective

To assess the relationships between serum bilirubin concentrations on the one hand, and leukocyte count, C-reactive protein and survival on the other hand, in infants with Gram-negative sepsis.

Methods

Retrospectively, we retrieved clinical and biochemical data from infants less than 90 days of age with a blood culture-proven Gram-negative sepsis between January 1998 and December 2005.

Results

We identified 92 infants with Gram-negative sepsis in the indicated period. Median gestational age was 29 (24-42) weeks. 22 Patients died. Preceding sepsis, median total serum bilirubin concentrations were below 150 μmol/L. Median concentrations of conjugated bilirubin concentrations increased (+ 63%, p < 0.05), and median concentrations of unconjugated bilirubin decreased (− 36%, p < 0.05) in infants with Gram-negative sepsis. Median total bilirubin concentrations before and during sepsis were not significantly different between survivors and non-survivors. Changes in bilirubin concentrations were not significantly correlated with changes in either white blood cell count or C-reactive protein.

Conclusion

Present data do not support the concept that bilirubin positively affects survival or the inflammatory response in infants with Gram-negative sepsis.  相似文献   
34.
With the improved treatment of the pulmonary complications of cystic fibrosis (CF), gastrointestinal problems have become more important in the morbidity in CF. A hallmark of the gastrointestinal phenotype of CF, apart from pancreatic insufficiency, is a disruption of bile acid homeostasis. Bile acid homeostasis is important for many gastrointestinal processes including fat absorption, inflammation, microbial composition, as well as regulation of whole body energy metabolism. This review describes the impairment of bile acid homeostasis in CF, its possible consequences for gastrointestinal and metabolic complications and its potential as a target for therapy.  相似文献   
35.
36.
To create a radiomics approach based on multiparametric magnetic resonance imaging (mpMRI) features extracted from an auto-fixed volume of interest (VOI) that quantifies the phenotype of clinically significant (CS) peripheral zone (PZ) prostate cancer (PCa). This study included 206 patients with 262 prospectively called mpMRI prostate imaging reporting and data system 3–5 PZ lesions. Gleason scores > 6 were defined as CS PCa. Features were extracted with an auto-fixed 12-mm spherical VOI placed around a pin point in each lesion. The value of dynamic contrast-enhanced imaging(DCE), multivariate feature selection and extreme gradient boosting (XGB) vs. univariate feature selection and random forest (RF), expert-based feature pre-selection, and the addition of image filters was investigated using the training (171 lesions) and test (91 lesions) datasets. The best model with features from T2-weighted (T2-w) + diffusion-weighted imaging (DWI) + DCE had an area under the curve (AUC) of 0.870 (95% CI 0.980–0.754). Removal of DCE features decreased AUC to 0.816 (95% CI 0.920–0.710), although not significantly (p = 0.119). Multivariate and XGB outperformed univariate and RF (p = 0.028). Expert-based feature pre-selection and image filters had no significant contribution. The phenotype of CS PZ PCa lesions can be quantified using a radiomics approach based on features extracted from T2-w + DWI using an auto-fixed VOI. Although DCE features improve diagnostic performance, this is not statistically significant. Multivariate feature selection and XGB should be preferred over univariate feature selection and RF. The developed model may be a valuable addition to traditional visual assessment in diagnosing CS PZ PCa. • T2-weighted and diffusion-weighted imaging features are essential components of a radiomics model for clinically significant prostate cancer; addition of dynamic contrast-enhanced imaging does not significantly improve diagnostic performance. • Multivariate feature selection and extreme gradient outperform univariate feature selection and random forest. • The developed radiomics model that extracts multiparametric MRI features with an auto-fixed volume of interest may be a valuable addition to visual assessment in diagnosing clinically significant prostate cancer.  相似文献   
37.
PURPOSE: To investigate the effect of an endorectal balloon (ERB) and an off-line correction protocol on the day-to-day, interfraction prostate gland motion, in patients receiving external beam radiotherapy for prostate cancer. METHODS AND MATERIALS: In 22 patients, irradiated with an ERB in situ (ERB group) and in 30 patients without an ERB (No-ERB group), prostate displacements were measured daily in three orthogonal directions with portal images. Implanted gold markers and an off-line electronic portal imaging correction protocol were used for prostate position verification and correction. Movie loops were analyzed to evaluate prostate motion and rectal filling variations. RESULTS: The off-line correction protocol reduced the systematic prostate displacements, equally for the ERB and No-ERB group, to 1.3-1.8 mm (1 SD). The mean 3D displacement was reduced to 2.8 mm and 2.4 mm for the ERB and No-ERB group, respectively. The random interfraction displacements, relative to the treatment isocenter, were not reduced by the ERB and remained nearly unchanged in all three directions: 3.1 mm (1 SD) left-right, 2.6 mm (1 SD) superior-inferior, and 4.7 mm (1 SD) for the anterior-posterior direction. These day-to-day prostate position variations can be explained by the presence of gas and stool beside the ERB. CONCLUSIONS: The off-line corrections on the fiducial markers are effective in reducing the systematic prostate displacements. The investigated ERB does not reduce the interfraction prostate motion. Although the overall mean displacement is low, the day-to-day interfraction motion, especially in anterior-posterior direction, remains high compared with the systematic displacements.  相似文献   
38.
A disturbed methylation has been proposed as a mechanism via which homocysteine is associated with diseases like vascular disease, neural tube defects and mental disorders. Catechol-O-methyltransferase (COMT) is involved in the S-adenosylmethionine-dependent methylation of catecholamines and catecholestrogens and in this way contributes to homocysteine synthesis. COMT dysfunction has been related to schizophrenia and breast cancer. We hypothesized that COMT dysfunction by virtue of functional genetic polymorphisms may affect plasma total homocysteine (tHcy). Our primary objective was to study the association between common COMT polymorphisms and tHcy. Secondly, we evaluated these polymorphisms as a risk factor for recurrent venous thrombosis. We obtained genotype data from four polymorphisms in the COMT gene (rs2097603, rs4633, rs4680 [324G>A] and rs174699) from 401 population-based controls. We performed haplotype analysis to investigate the association between common haplotypes and tHcy. In addition, we assessed the rs4680 variant as a genetic risk factor in a case-control study on recurrent venous thrombosis (n = 169). We identified a common haplotype that was significantly associated with tHcy levels. This effect was largely explained by the rs4680 variant, resulting in an increase in tHcy of 10.4% (95% CI 0.01 to 0.21, p = 0.03) for 324AA compared with 324GG subjects. Interestingly, we found that the 324AA genotype was more common in venous thrombosis patients (OR 1.61 [95% CI 0.97 to 2.65], p = 0.06) compared to control subjects. We show that the COMT rs4680 variant modulates tHcy, and might be associated with venous thrombosis risk as well.  相似文献   
39.
40.
Multimodality PET/CT of the liver can be performed with an integrated (hybrid) PET/CT scanner or with software fusion of dedicated PET and CT. Accurate anatomic correlation and good image quality of both modalities are important prerequisites, regardless of the applied method. Registration accuracy is influenced by breathing motion differences on PET and CT, which may also have impact on (attenuation correction-related) artifacts, especially in the upper abdomen. The impact of these issues was evaluated for both hybrid PET/CT and software fusion, focused on imaging of the liver. METHODS: Thirty patients underwent hybrid PET/CT, 20 with CT during expiration breath-hold (EB) and 10 with CT during free breathing (FB). Ten additional patients underwent software fusion of dedicated PET and dedicated expiration breath-hold CT (SF). The image registration accuracy was evaluated at the location of liver borders on CT and uncorrected PET images and at the location of liver lesions. Attenuation-correction artifacts were evaluated by comparison of liver borders on uncorrected and attenuation-corrected PET images. CT images were evaluated for the presence of breathing artifacts. RESULTS: In EB, 40% of patients had an absolute registration error of the diaphragm in the craniocaudal direction of >1 cm (range, -16 to 44 mm), and 45% of lesions were mispositioned >1 cm. In 50% of cases, attenuation-correction artifacts caused a deformation of the liver dome on PET of >1 cm. Poor compliance to breath-hold instructions caused CT artifacts in 55% of cases. In FB, 30% had registration errors of >1 cm (range, -4 to 16 mm) and PET artifacts were less extensive, but all CT images had breathing artifacts. As SF allows independent alignment of PET and CT, no registration errors or artifacts of >1 cm of the diaphragm occurred. CONCLUSION: Hybrid PET/CT of the liver may have significant registration errors and artifacts related to breathing motion. The extent of these issues depends on the selected breathing protocol and the speed of the CT scanner. No protocol or scanner can guarantee perfect image fusion. On the basis of these findings, recommendations were formulated with regard to scanner requirements, breathing protocols, and reporting.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号