Medullary thyroid carcinoma (MTC) is a rare form of thyroid cancer representing about 10% of all thyroid malignancies. It occurs mostly as a sporadic tumor or in association with autosomal dominant inherited cancer syndromes--multiple endocrine neoplasia (MEN) types 2A and 2B and familial MTC. Germline mutations in exons 8, 10, 11, 13, 14, 15 and 16 of the RET proto-oncogene are found in most of the familial cases. There are only a few published data reporting multiple germline mutations in the RET proto-oncogene. We have detected double germline mutations in 2 different exons on the same RET allele in two MEN 2 families. In the MEN 2A family, double germline mutation in exons 10 (Cys620Phe) and 13 (Tyr791Phe) was detected. In the MEN 2B family, beside the classical germline mutation in exon 16 (Met918Thr) a second germline mutation in exon 13 (Tyr791Phe) was found. This study revealed that MEN 2 syndromes can also be caused by double germline mutations in the RET proto-oncogene and these families can be added to small worldwide cohort of families with multiple germline mutations. 相似文献
Sniff nasal inspiratory pressure (SNIP) measurement is a volitional noninvasive assessment of inspiratory muscle strength. A maximum of 10 sniffs is generally used. The purpose of the present study was to investigate whether the maximum SNIP improved after the tenth sniff. In total, 20 healthy volunteers and 305 patients with various neuromuscular and lung diseases were encouraged to perform 40 and 20 sniffs, respectively. The best SNIP among the first 10 sniffs was lower than the best SNIP among the next 10 sniffs in the healthy volunteers and patients. The SNIP improvement after the twentieth sniff was marginal. In conclusion, a learning effect persists after the tenth sniff. The current authors suggest using 10 additional sniffs when the best result of the first 10 sniffs is slightly below normal, or when sniff nasal inspiratory pressure is used to monitor a progressive decline in inspiratory muscle strength. 相似文献
BACKGROUND: Many mild-to-moderately obese individuals (body mass index [BMI] 30-35 kg/m(2)) have serious diseases related to their obesity. Nonoperative therapy is ineffective in the long term, yet surgery has never been made widely available to this population. METHODS: Between 1996 and 2004, 93 patients with a BMI of 30-35 kg/m(2) underwent laparoscopic adjustable gastric banding with the LAP-BAND. All patients were referred by their primary physician, entered into a comprehensive bariatric surgery program at one Australian center, and operated on by one surgeon. Data on all patients were collected prospectively and entered into an electronic registry. The study parameters included preoperative age, gender, BMI, presence of co-morbidities, percentage of excess weight loss, and resolution of co-morbidities. RESULTS: The mean age was 44.6 years (range 16-76), mean weight was 98 kg, and the mean BMI was 32.7 kg/m(2) (range 30-34). Of the 93 patients, 42 (45%) had co-morbidities, including asthma, diabetes, hypertension, and sleep apnea. The proportion of patients in follow-up was 79%, 85%, and 89% at 1, 2, and 3 years, respectively. The mean weight was reduced to 71 kg at 1 year, 72 kg at 2 years, and 72 kg at 3 years. The mean BMI was reduced to 27.2 +/- 2.2, 27.3 +/- 3.1, and 27.6 +/- 3.7 kg/m(2), respectively, and the mean percentage of excess weight loss was 57.9% +/- 24.5%, 57.6 +/- 29.3%, and 53.8% +/- 32.8% at 1, 2, and 3 years, respectively. At 3 years, the BMI was 18-24 kg/m(2) in 34%, 25-29 kg/m(2) in 51%, and 30-35 kg/m(2) in 10%. At 3 years, the percentage of excess weight loss was <25% in 10%, 25-50% in 24%, 50-75% in 51%, and >75% in 10%. The co-morbidities improved or completely resolved in most patients. No mortality occurred. CONCLUSION: We are very encouraged by this series of low BMI patients treated with the LAP-BAND. Their weight loss has been good, the complications have been minimal, and the co-morbidities have partially or wholly resolved. With additional study, it is reasonable to expect the weight guidelines for bariatric surgery to be altered to include patients with a BMI of 30-35 kg/m(2). 相似文献
Background: Few studies have examined the use of ultrasound for sciatic nerve localization. The authors evaluated the usefulness of low-frequency ultrasound in identifying the sciatic nerve at three locations in the lower extremity and in guiding needle advancement to target before nerve stimulation.
Methods: In this prospective observational study, 15 volunteers underwent sciatic nerve examination using a curved ultrasound probe in the range of 2-5 MHz and a Philips-ATL 5000 unit (ATL Ultrasound, Bothell, WA) in the gluteal, infragluteal, and proximal thigh regions. Thereafter, an insulated block needle was advanced inline with the ultrasound beam to reach the nerve target, which was further confirmed by electrical stimulation. The quality of sciatic nerve images, ease of needle to nerve contact, threshold stimulating current, and resultant motor response were recorded.
Results: The sciatic nerve was successfully identified in the transverse view as a solitary predominantly hyperechoic structure on ultrasound in all of the three regions examined. The target nerve was visualized easily in 87% and localized within two needle attempts in all patients. Nerve stimulation was successful in 100% after two attempts with a threshold current of 0.42 +/- 0.12 (mean +/- SD) eliciting foot plantarflexion or dorsiflexion. 相似文献
Abstract: Background: Fetal pulse oximetry improves the assessment of fetal well‐being during labor. The objective of this study was to evaluate women's satisfaction with their experience with this additional technology. Methods: We surveyed women participating in the FOREMOST trial, a randomized controlled trial comparing the addition of fetal pulse oximetry (FPO) to conventional cardiotocograph (CTG) monitoring (intervention group), versus CTG‐only (control group), in the presence of nonreassuring fetal status during labor. Our survey evaluated 3 aspects of women's experience: labor, fetal monitoring, and participation in the research. The survey was administered within a few days of giving birth and repeated 3 months later. Results: No differences were found between the intervention and control groups for women's evaluations of their labor, fetal monitoring, research, or overall experiences when surveyed on both occasions. Within each study group, a small but statistically significant decline occurred in women's scores for their experience of labor and overall experience from the initial survey close to the time of giving birth, to 3 months later. The magnitude of differences in responses over time was similar for the both groups. Women were more satisfied after a spontaneous or assisted vaginal birth than after cesarean section. Length of time the research midwife was present had a significant positive effect on women's ratings of their experience several days after giving birth (p = 0.006), but no effect at 3 months. Conclusions: The addition of fetal pulse oximetry for the assessment of fetal well‐being during labor did not affect childbearing women's perceptions of fetal monitoring or their labor. Women evaluated their experience in the research process positively overall. Small changes occurred in women's perception of their satisfaction over time. (BIRTH 33:2 June 2006)相似文献