Background: Previous studies have shown that propofol and sevoflurane enhance the function of [gamma]-aminobutyric acid type A (GABAA) receptors. However, it is not known whether these two drugs modulate the same molecular pathways. In addition, little is known about receptor function in the presence of both propofol and sevoflurane. The aim of this study was to better understand the interactions of propofol and sevoflurane with the GABAA receptor.
Methods: Wild-type [alpha]1, [beta]2, [gamma]2s GABAA receptor subunit complementary DNAs were transfected into human embryonic kidney cells grown on glass coverslips using a calcium phosphate transfection method. After transfection (36-72 h), cells were whole cell patch clamped and exposed to combinations of the following: 0.3-1,000 [mu]m [gamma]-aminobutyric acid (GABA), 0-10 [mu]m propofol, and 0-1,650 [mu]m sevoflurane. Chemicals were delivered to the cells using two 10-channel infusion pumps and a rapid solution exchanger.
Results: Both propofol and sevoflurane alone enhanced the amplitude of GABAA receptor responses to submaximal concentrations of GABA in a dose-dependent manner. The enhancement was underpinned by an increase in the apparent affinity of the receptor for GABA. Coapplication of both anesthetics further enhanced the apparent affinity of the receptor for GABA. 相似文献
The aim of the present study was to explore differences in the clinical expression, clinical diagnoses and management of airway diseases in a primary-care setting. Patients aged >or=35 yrs who had ever smoked were enrolled when they presented for any reason to one of eight rural primary-care practices. Respiratory symptom questionnaires and spirometry were administered. In total, 1,034 patients had acceptable and reproducible spirometry, of whom 550 (53%) were males and 484 (47%) were females. Males smoked more than females (41.2 versus 29.2 pack-yrs) respectively, and were more likely to have a pre-bronchodilator forced expiratory volume in one second/forced vital capacity <0.70 at 22.4 versus 11.8%, respectively. However, more females than males reported breathlessness (51.0 versus 42.8%, respectively), a prior diagnosis compatible with airflow obstruction and taking respiratory medications (23.4 versus 14.9%, respectively). In conclusion, the current results suggest that females are more likely than males to report breathlessness and be prescribed respiratory medications independent of differences in the severity of airflow obstruction. 相似文献
A very high ventilatory response to hypoxia is believed necessary to reach extreme altitude without oxygen. Alternatively, the excessive ventilation could be counterproductive by exhausting the ventilatory reserve early on. To test these alternatives, 11 elite climbers (2004 Everest-K2 Italian Expedition) were evaluated as follows: 1) at sea level, and 2) at 5,200 m, after 15 days of acclimatisation at altitude. Resting oxygen saturation, minute ventilation, breathing rate, hypoxic ventilatory response, maximal voluntary ventilation, ventilatory reserve (at oxygen saturation = 70%) and two indices of ventilatory efficiency were measured. Everest and K2 summits were reached 29 and 61 days, respectively, after the last measurement. Five climbers summited without oxygen, the other six did not, or succeeded with oxygen (two climbers). At sea level, all data were similar. At 5,200 m, the five summiters without oxygen showed lower resting minute ventilation, breathing rate and ventilatory response to hypoxia, and higher ventilatory reserve and ventilatory efficiency, compared to the other climbers. Thus, the more successful climbers had smaller responses to hypoxia during acclimatisation to 5,200 m, but, as a result, had greater available reserve for the summit. A less sensitive hypoxic response and a greater ventilatory efficiency might increase ventilatory reserve and allow sustainable ventilation in the extreme hypoxia at the summit. 相似文献
BACKGROUND: Impaired neuropsychological test performance, especially on tests of executive function and attention, is often seen in children diagnosed with autism spectrum disorders (ASD). Structures involved in fronto-striatal circuitry, such as the caudate nucleus, may support these cognitive abilities. However, few studies have examined caudate volumes specifically in children with ASD, or correlated caudate volumes to cognitive ability. METHODS: Neuropsychological test scores and caudate volumes of children with ASD were compared to those of children with bipolar disorder (BD) and of typically developing (TD) children. The relationship between test performance and caudate volumes was analyzed. RESULTS: The ASD group displayed larger right and left caudate volumes, and modest executive deficits, compared to TD controls. While caudate volume inversely predicted performance on the Wisconsin Card Sorting Test in all participants, it differentially predicted performance on measures of attention across the ASD, BD and TD groups. CONCLUSIONS: Larger caudate volumes were related to impaired problem solving. On a test of attention, larger left caudate volumes predicted increased impulsivity and more omission errors in the ASD group as compared to the TD group, however smaller volume predicted poorer discriminant responding as compared to the BD group. 相似文献
PURPOSE: The advantages of a focometer (FOCOMETER) over other methods of refraction for use in developing countries are that it is lightweight, compact, relatively inexpensive, fairly quick, and easy to use with minimal training. This clinical trial compared the repeatability, validity, and ease of use of the focometer with an autorefractor. METHODS: The refractive status of the right eye of 80 participants was determined with an autorefractor (Canon RK3). Three measurements were also taken with the focometer. RESULTS: The spherical equivalent (M) of the focometer was 0.25 D more positive than the autorefractor (p < 0.001) and 84% of measurements were within 0.75 D of the autorefractor. The autorefractor detected astigmatism in 91% (73) of the eyes, whereas the focometer identified only 32% (26). The design of the clock target restricts cylinder axis accuracy to the nearest 15 degrees . There was evidence of a learning effect for the focometer: the second and third measurements were more repeatable in the untrained group. There were no differences between the mean (1.03 +/- 2.28) and third focometer (-1.05 +/- 2.32) measurements (p = 0.34). However, using the third focometer measurement, 94% of participants had visual acuities of at least 6/12(-2). CONCLUSIONS: This study highlighted the focometer's restricted power range, inaccuracy of astigmatism and axis determination, and dependence on subject understanding and compliance. Therefore, in most clinical settings, the focometer would not be adequate for quantifying refractive error, but the focometer spherical equivalent was within acceptable limits of the autorefractor, and the visual acuity with lenses determined by the focometer indicates its potential usefulness in public health settings, especially where only spherical ready-made spectacles are dispensed. There may be more cost-effective ways to determine refractive error in these circumstances. A potentially important enhancement in focometer methodology that improves its ease of use was identified: use only the third measurement for each eye. 相似文献
BACKGROUND: An augmented reality tool for computer assisted surgery named X-Scope allows visual tracking of real anatomical structures in superposition with volume rendered CT or MRI scans and thus can be used for navigated translocation of bony segments. METHODS: In a feasibility study X-Scope was used in orthognathic surgery to control the translocation of the maxilla after Le Fort I osteotomy within a bimaxillary procedure. The situation achieved was compared with the pre-operative situation by means of cephalometric analysis on lateral and frontal cephalograms. RESULTS: The technique was successfully utilized in 5 patients. Maxillary positioning using X-Scope was accomplished accurately within a range of 1mm. The tool was used in all cases in addition to the usual intra-operative splints. A stand-alone application without conventional control does not yet seem reasonable. CONCLUSION: Augmented reality tools like X-Scope may be helpful for controlling maxillary translocation in orthognathic surgery. The application to other interventions in cranio-maxillofacial surgery such as Le Fort III osteotomy, fronto-orbital advancement, and cranial vault reshaping or repair may also be considered. 相似文献