Background: General anesthetics inhibit evoked release of classic neurotransmitters. However, their actions on neuropeptide release in the central nervous system have not been well characterized.
Methods: The effects of representative intravenous and volatile anesthetics were studied on the release of sulfated cholecystokinin 8 (CCK8s), a representative excitatory neuropeptide, from isolated rat cerebrocortical nerve terminals (synaptosomes). Basal, elevated KCl depolarization-evoked and veratridine-evoked release of CCK8s from synaptosomes purified from rat cerebral cortex was evaluated at 35[degrees]C in the absence or presence of extracellular Ca2+. CCK8s released into the incubation medium was determined by enzyme-linked immunoassay after filtration.
Results: Elevation of extracellular KCl concentration (to 15-30 mm) or veratridine (10-20 [mu]m) stimulated Ca2+-dependent CCK8s release. Basal, elevated KCl- or veratridine-evoked CCK8s release was not affected significantly by propofol (12.5-50 [mu]m), pentobarbital (50 and 100 [mu]m), thiopental (20 [mu]m), etomidate (20 [mu]m), ketamine (20 [mu]m), isoflurane (0.6-0.8 mm), or halothane (0.6-0.8 mm). 相似文献
Cancer Chemotherapy and Pharmacology - Addition of solid doxorubicin or solutions to pre-formed liposomes proved to be the optimal method for incorporating the drug into liposomes whilst... 相似文献
We describe a simple direct extraction method for the gas-liquid chromatography determination of serum valproic acid. The working range for the assay is 2-180 mg/L and our within-run precision was 5.8 and 4.3% at the 40 and 90 mg/L concentrations respectively. Hemolyzed and lipemic sera as well as samples from patients with hyperbilirubinemia and from patients with decreased renal function were put through the assay and no interfering peaks were noted. Interference occurred when teflon-lined screw caps were used during the extraction step. The method was proven to be accurate by linear regression analysis of samples containing weighed-in amounts of valproic acid. The above assay was compared to an enzyme immunoassay technique (EMIT). The working range for the latter is 10-150 mg/L and the with-run precision was 10.8 and 5.9% and 90 mg/L concentration respectively. Samples were run by both the gas-liquid chromatograph and enzyme immunoassay methods and gave very similar results over the range 16-139 mg/L. 相似文献
1 Contractile responses of canine intestinal circular and longitudinal muscles to field stimulation (20 Hz, 1 ms, 30 V/cm, for 5 s) were inhibited by treatment with atropine (0.1 microgram/ml), indicating that the response to field stimulation was mediated by acetylcholine (ACh). 2 Prostaglandins E1 (PGE1), PGE2 and PGF2 alpha inhibited the response of circular but not longitudinal muscle to field stimulation, although PGF2 alpha was less effective than PGE1 and E2. 3 PGE1 was much less active in inhibiting the response of circular muscle to ACh than to field stimulation, suggesting that prostaglandins might act predominantly at prejunctional sites to prevent the release of ACh. 4 Indomethacin (1 microgram/ml) potentiated the response of circular muscle but not longitudinal muscle to field stimulation. 5 Release of PGE-like compounds from circular muscle only, was increased by field stimulation at 20 Hz (total of 1000 pulses) and ACh (10 micrograms/ml), but not by a lower frequency (2 Hz, total of 2400 pulses) which produced only a slight contraction. This finding may indicate that prostaglandins were released predominantly from the muscle. 6 Prostaglandins may exert a negative feedback mechanism of excitatory transmission in circular muscle but not in longitudinal muscle of canine small intestine. 相似文献
The purpose of this project was to design an efficient, low cost, and portable system for renography suitable for clinical use. The principles involved in the renographic test, and the procedures and calculations which act on the design of our system, are given. The system consists of an Apple II Plus computer equipped with 48K memory, two disk drives with diskettes of 143K each, a thermal printer with graphic capability, the Microsoft Z80 card, and an interface which is specifically designed for renographic data acquisition. 相似文献
The presence of accessory channels between the liver and extrahepatic bile ducts has long been recognised by anatomists and the division of such ducts may be a cause of bile leakage following cholecystectomy. However, visualisation of accessory bile ducts at operation is difficult as they are often small and sometimes less than 1 mm in diameter. Cholangiography has been used to help in the identification of accessory ducts in 50 patients included in a prospective trial. X-rays were taken after dissection of the gall bladder from its bed and extravasation of contrast was seen on five occasions (10%) suggesting leakage from divided accessory ducts. The identification of damage to accessory bile ducts in 10% of patients suggests that this may occur more frequently than previously supposed. 相似文献
A total of 106 pairs of identical twins, of whom 56 were concordant and 50 discordant for insulin-dependent diabetes, were typed for HLA-DR. In both the concordant and discordant groups there was a high prevalence of the antigens DR3 and DR4, a low prevalence of DR5 and DR7, and a virtual absence of DR2. The heterozygous phenotype DR3,DR4 was more prevalent in concordant than discordant pairs. This was therefore the first demonstration of a genetic difference between concordant and discordant identical twin pairs. These findings suggest that possession of both DR3 and DR4 antigens confers a greater genetic predisposition to insulin-dependent diabetes than does the possession of either antigen alone. 相似文献
Summary The quantity of protein and carbohydrate comprising the matrix of calcium oxalate monohydrate (COM) renal stones was found
to decrease with distance from the surface of the stone. The average organic concentration of stones 3 to 30 mm in diameter
ranged from 5.7% at the surface to 2.7% at the core. This concentration gradient suggests matrix involvement in a “growth
front” on stone surfaces with migration of organic material from the “older” interior. The matrix distribution was not readily
correlated with density variations or with the presence of hydroxyapatite or calcium oxalate dihydrate. Surface matrix concentrations
were greater than amounts predicted by physical adsorption. Electron microscopy confirmed the presence of the organic-rich
surface layer and also suggested that increase in stone size occurs predominantly by crystal growth with microcrystal aggregates
as growth centers. 相似文献
Understanding the normal anatomy of the shoulder and its variations is important for the proper interpretation of MR images. This study was performed to describe variations in the normal labral-capsular complex as seen on MR images. MR images of 52 shoulders in 30 asymptomatic volunteers and 27 shoulders of symptomatic patients who had subsequent arthroscopy and/or reconstructive surgery were obtained with 1.5-T MR. The 52 scans of the asymptomatic group were reviewed by three radiologists in conference, and the assessment of labral shapes and capsular insertions was done by consensus. The 27 MR scans of the shoulders in the symptomatic group were reviewed by one radiologist before and after the asymptomatic cases were interpreted. Differences in these two interpretations were shown on receiver-operating-characteristic curves by using the results of subsequent arthroscopy and surgery as the gold standard. The anterior and posterior parts of the labra, respectively, varied in shape but showed several dominant features: triangular (45%, 73%), round (19%, 12%), cleaved (15%, 0%), notched (8%, 0%), flat (7%, 6%), and absent (6%, 8%). Most capsules inserted anteriorly on the labrum (47%) or glenoid rim (49%). All posterior insertions were on the labrum (100%). Intrinsic labral signal was noted on proton density-weighted images, but never on T2-weighted images. Receiver-operating-characteristic curves from interpretations of the symptomatic and clinical cases made before and after evaluation of the asymptomatic shoulders showed the interpretations improved considerably after scans of asymptomatic volunteers were studied. Our study reveals a wide variability in the MR appearance of the labral-capsular complex in asymptomatic shoulders. 相似文献