Background: To date, no study has explored the effect of bent length on lightwand intubation. For successful intubation in daily practice, the authors found that bent length should be approximated to the patient's thyroid prominence-to-mandibular angle distance (TMD), but some patients have a TMD much shorter than the suggested bent length range. The purposes of this study were to understand TMD distribution in adults and to test the influence of bent length on lightwand intubation.
Methods: The TMD, airway, and demographic data of 379 patients were collected. To test the bent length influence, patients were enrolled in group A (158 patients, TMD <= 5.5 cm) and group B (131 patients, TMD > 5.5 cm) and were intubated randomly using the lower (6.5 cm) and upper (8.5 cm) limits of the suggested range. Success rate and lightwand search time were compared.
Results: In group A, the success rate was 98.8% with 6.5-cm bent length and 78.2% with 8.5-cm bent length (P < 0.05). Search times were 5.7 +/- 2.90 and 8.9 +/- 5.80 s with 6.5- and 8.5-cm bent length, respectively (P < 0.01). In group B, there was no statistical difference in success rate and search time between 6.5- and 8.5-cm bent length. 相似文献
PURPOSE: To investigate the corneal and scleral permeability of nalidixic acid and synthesized fluoroquinolones and their in vivo pharmacokinetics in rabbits. METHODS: The corneal and scleral permeability coefficients of ciprofloxacin, norfloxacin, cinoxacin, enoxacin, and ofloxacin were determined in rabbits using high performance liquid chromatography (HPLC). The aqueous humor levels of norfloxacin and ciprofloxacin were measured separately by topical instillation of 0.3% solutions of the two drugs onto rabbit eyes. RESULTS: Nalidixic acid had a higher corneal permeability coefficient (17.3 +/- 3.56 x 10(-6) cm/second) than all other drugs tested (p < 0.01). Corneal permeability coefficients in rabbits among ciprofloxacin, norfloxacin, cinoxacin, enoxacin, and ofloxacin were not significantly different (p > 0.1). Comparing the corneal and scleral permeability coefficients, only values for nalidixic acid were not significantly different (17.35 +/- 3.56 x l0(-6) cm/second versus 22.69 +/- 5.19 x 10(-6) cm/second, p > 0.05), while all other drugs had scleral permeability coefficients 8 to 10 times greater than corneal permeability coefficients. The mean aqueous humor concentration of norfloxacin and ciprofloxacin at 60 minutes to 180 minutes after instillation was around 0.3 microg/mL, a value higher than MIC90 of most bacteria. 相似文献
Background: Malposition of percutaneously inserted chest tubes is considered as a rare complication in critically ill patients. Its incidence, however, remains uncertain. The aims of the study were to assess the true incidence of chest tube malposition in critically ill patients and to identify predicting factors.
Methods: The authors prospectively studied 122 chest tubes percutaneously inserted in 75 consecutive critically ill patients. For clinical reasons independent of the study, thoracic computed tomography scanning was performed in 63 patients, allowing direct visualization of 106 chest tubes. Based on these findings, chest tube position was classified as intrapleural, intrafissural, or intraparenchymal. Factors predicting chest tube malposition were analyzed by univariate and multivariate analysis.
Results: The mean delay between chest tube placement and thoracic scan was 3.5 +/- 2.9 days. Twenty-two chest tubes were diagnosed as being intrafissural (21%), and 10 were diagnosed as being intraparenchymal (9%). The only predicting factor associated with the risk of malposition was the use of a trocar for the percutaneous insertion of the chest tube (P = 0.032). 相似文献
目的:建立大鼠肝脏移植急性排斥反应模型并改进其手术技巧,对所建模型进行评价。方法:采用近交系雄性DA大鼠60只,Lewis大鼠120只,分为两组,其中A组30例:Lewis大鼠为供体(n=30),Lewis大鼠为受体;B组60例:DA大鼠为供体(n=60),Lewis大鼠为受体。采用改良“二袖套”法建立肝脏移植模型,观察手术成功率、平均存活时间、术后第1、3、5、7和10 d各时相点血清丙氨酸氨基转移酶(ALT)、总胆红素(TBIL)水平以及移植肝脏的病理学变化。结果:手术成功率为93.3%(84/90);总耗时(90.0±15.0)min;无肝期时间(14.2±2.6)min;平均存活时间A组超过100d,B组(16.2±1.4)d;术后第5 d B组血清ALT和TBIL升高,与A组比较差异非常显著(P<0.01);B组移植肝脏病理检查有明显的排斥反应,而A组没有。结论:DA→LEW(Lewis)大鼠的品系组合是稳定的肝脏移植急性排斥反应模型;通过改进手术技巧提高了手术成功率,为进一步研究提供技术保障。 相似文献