BACKGROUND: Chronic cough affects at least 7% of children, and the impact of this on families is significant. Although adult cough-specific quality-of-life (QOL) instruments have been shown to be a useful cough outcome measure, no suitable cough-specific QOL for parents of children with chronic cough exists. This article compares two methods of item reduction (clinical impact and psychometric) and reports on the statistical properties of both QOL instruments. METHOD: One hundred seventy children (97 boys and 73 girls; median age, 4 years; interquartile range, 3 to 7.25 years) and one of their parents participated. A preliminary 50-item parent cough-specific QOL (PC-QOL) questionnaire was developed from conversations with parents of children with chronic cough (ie, cough for > 3 weeks). Parents also completed generic QOL questionnaires (eg, Pediatric Quality of Life Inventory, version 4.0 [PedsQL4.0] and the 12-item Short Form Health Survey, version 2 [SF-12v2]). RESULTS: The clinical impact and psychometric method of item reduction resulted in 27-item and 26-item PC-QOL questionnaires, respectively, with approximately 50% of items overlapping. Internal consistency among the final items from both methods was excellent. Some evidence for concurrent and criterion validity of both methods was established as significant correlations were found between subscales of the PC-QOL questionnaire and the scales of the SF-12v2 and PedsQL4.0 scores. The PC-QOL questionnaire derived from both methods was sensitive to change following an intervention. CONCLUSION: Chronic cough significantly impacts on the QOL of both parents and children. Although the PC-QOL questionnaires derived from a clinical impact method and from a psychometric method contained different items, both versions were shown to be internally consistent and valid. Further testing is required to compare both final versions to objective and subjective cough measures. 相似文献
This study examined: 1) the impact of myectomy on postoperative mitral regurgitation (MR) and 2) the association between the severity of MR and the left ventricular outflow tract (LVOT) gradient.
BACKGROUND
For patients with hypertrophic obstructive cardiomyopathy (HOCM) and MR, controversy exists as to whether myectomy alone is sufficient in eliminating MR. Furthermore, the relationship between the degree of MR and the LVOT peak gradient has not been well defined.
METHODS
We performed pre- and postoperative transthoracic as well as intraoperative transesophageal studies in 104 consecutive patients with HOCM undergoing septal myectomy. Left ventricular outflow tract gradient and the nature of MR were assessed.
RESULTS
In the 93 patients without independent mitral valve disease, a relationship was observed between MR severity and the LVOT gradient. Left ventricular outflow tract gradient (mean ± standard deviation) for trivial, mild, moderate and severe MR were: 23.2 ± 19.1, 43.8 ± 25.4, 70.1 ± 21.0 and 104 ± 21.0 mm Hg (p < 0.001). Early postoperative, MR was absent or trivial in 80%, mild in 19% and moderate in 1%. None of these patients required additional mitral valve surgery. For patients with independent mitral valve disease (n = 11), five required mitral valve surgery as well as myectomy. The remainder had significant reductions in the degree of MR with myectomy alone.
CONCLUSIONS
For patients with HOCM and MR not due to independent mitral valve disease, myectomy significantly reduced the degree of MR, without requirement for additional mitral valve surgery. In these patients the severity of MR was directly related to the magnitude of the LVOT gradient. 相似文献
BACKGROUND: In counseling patients with a history of stroke, clinicians have limited information regarding the risks and benefits of alcohol consumption. OBJECTIVE: To examine the relationship between alcohol intake and risks of total and cardiovascular mortality in men with a history of stroke. METHODS: The study population consisted of 112 528 men from the enrollment cohort of the Physicians' Health Study, 1320 of whom reported a baseline history of stroke. Men provided self-reported data on alcohol consumption, which was classified into 1 of 4 categories: rarely or never drink, very light (<1 drink per week), light (1-6 drinks per week), or moderate (> or =1 drink per day). Cox proportional hazards models were used to assess the relative risks of mortality associated with alcohol consumption, after adjustment for major coronary risk factors. RESULTS: During a mean follow-up of 4(1/2) years, 369 men died, 267 of whom died of cardiovascular disease. Compared with men with a history of stroke who drank rarely or never, those with a very light to moderate alcohol intake had multivariate relative risks for total mortality of 0.88 (95% confidence interval [CI], 0.60-1.28), 0.64 (95% CI, 0.48-0.85), and 0.71 (95% CI, 0.54-0.94), respectively (P =.03 for trend); and relative risks for cardiovascular mortality of 0.89 (95% CI, 0.58-1.36), 0.56 (95% CI, 0.40-0.79), and 0.64 (95% CI, 0.46-0.88) P =.008 for trend). Compared with age-adjusted models, adjustment for major coronary risk factors did not significantly change risk estimates for total or cardiovascular mortality. CONCLUSIONS: These data indicate a possible inverse association between light to moderate alcohol intake and risks of total and cardiovascular mortality in men with a history of stroke. More data are needed to confirm or refute these results. 相似文献
OBJECTIVE: Chronic beta-adrenoceptor antagonist (beta-blocker) treatment reduces the incidence of reversion to AF in patients, possibly via an adaptive myocardial response. However, the underlying electrophysiological mechanisms are presently unclear. We aimed to investigate electrophysiological changes in human atrial cells associated with chronic treatment with beta-blockers and other cardiovascular-acting drugs. METHODS: Myocytes were isolated enzymatically from the right atrial appendage of 40 consenting patients who were in sinus rhythm. The cellular action potential duration (APD), effective refractory period (ERP), L-type Ca(2+) current (I(CaL)), transient (I(TO)) and sustained (I(KSUS)) outward K(+) currents, and input resistance (R(i)) were recorded using the whole cell patch clamp. Drug treatments and clinical characteristics were compared with electrophysiological measurements using simple and multiple regression analyses. P<0.05 was taken as statistically significant. RESULTS: In atrial cells from patients treated chronically with beta-blockers, the APD(90) and ERP (75 beats/min stimulation) were significantly longer, at 213+/-11 and 233+/-11 ms, respectively (n=15 patients), than in cells from non-beta-blocked patients, at 176+/-12 and 184+/-12 ms (n=11). These cells also displayed a significantly reduced action potential phase 1 velocity (22+/-3 vs. 34+/-3 V/s). Chronic beta-blockade was also associated with a significant reduction in the heart rate (58+/-3 vs. 69+/-5 beats/min) and in the density of I(TO) (8.7+/-1.3 vs. 13.7+/-2.1 pA/pF), an increase in the R(i) (214+/-24 vs. 132+/-14 MOmega), but no significant change in I(CaL) or I(KSUS). The I(TO) blocker 4-aminopyridine largely mimicked the changes in phase 1 and ERP associated with chronic beta-blockade, in cells from non-beta-blocked patients. Chronic treatment of patients with calcium channel blockers or angiotensin converting enzyme inhibitors (n=11-13 patients) was not associated with any significant changes in atrial cell electrophysiology. CONCLUSION: The observed atrial cellular electrophysiological changes associated with chronic beta-blockade are consistent with a long-term adaptive response, a type of 'pharmacological remodelling', and provide mechanistic evidence supportive of the anti-arrhythmic actions of beta-blockade. 相似文献
Technological development and improvements in Wearable Physiological Monitoring devices, have facilitated the wireless and continuous field-based monitoring/capturing of physiologic measures in healthy, clinical or athletic populations. These devices have many applications for prevention and rehabilitation of musculoskeletal disorders, assuming reliable and valid data is collected. The purpose of this study was to appraise the quality and synthesize findings from published studies on psychometric properties of heart rate measurements taken with the Zephyr Bioharness device.
Methods
We searched the Embase, Medline, PsycInfo, PuMed and Google Scholar databases to identify articles. Articles were appraised for quality using a structured clinical measurement specific appraisal tool. Two raters evaluated the quality and conducted data extraction. We extracted data on the reliability (intra-class correlation coefficients and standard error of measurement) and validity measures (Pearson/Spearman’s correlation coefficients) along with mean differences. Agreement parameters were summarised by the average biases and 95% limits of agreement.
Results
A total of ten studies were included: quality ratings ranged from 54 to 92%. The intra-class correlation coefficients reported ranged from 0.85–0.98. The construct validity coefficients compared against gold standard calibrations or other commercially used devices, ranged from 0.74–0.99 and 0.67–0.98 respectively. Zephyr Bioharness agreement error ranged from ??4.81 (under-estimation) to 3.00 (over-estimation) beats per minute, with varying 95% limits of agreement, when compared with gold standard measures.
Conclusion
Good to excellent quality evidence from ten studies suggested that the Zephyr Bioharness device can provide reliable and valid measurements of heart rate across multiple contexts, and that it displayed good agreements vs. gold standard comparators – supporting criterion validity.