The recent identification of a large array of different vaccinia virus‐derived CD8+ T‐cell epitopes offers a unique opportunity to systematically analyze the correlation between protective efficacy and variables such as kinetics of expression and function of viral proteins, binding affinity to MHC molecules, immunogenicity, and viral antigen processing/presentation. In the current study, 49 different H‐2b restricted epitopes were tested for their ability to protect peptide‐immunized C57Bl/6 mice from lethal i.n. challenge with vaccinia virus. The epitopes varied greatly in their ability to confer protection, ranging from complete protection with minimal disease to no protection at all. The function or kinetics of the viral antigen expression did not correlate with protective efficacy. However, binding affinity partially predicted protection efficacy and ultimately epitope immunogenicity and recognition of infected cells offered the best correlation. 相似文献
Several deep‐learning models have been proposed to shorten MRI scan time. Prior deep‐learning models that utilize real‐valued kernels have limited capability to learn rich representations of complex MRI data. In this work, we utilize a complex‐valued convolutional network (?Net ) for fast reconstruction of highly under‐sampled MRI data and evaluate its ability to rapidly reconstruct 3D late gadolinium enhancement (LGE) data. ?Net preserves the complex nature and optimal combination of real and imaginary components of MRI data throughout the reconstruction process by utilizing complex‐valued convolution, novel radial batch normalization, and complex activation function layers in a U‐Net architecture. A prospectively under‐sampled 3D LGE cardiac MRI dataset of 219 patients (17 003 images) at acceleration rates R = 3 through R = 5 was used to evaluate ?Net . The dataset was further retrospectively under‐sampled to a maximum of R = 8 to simulate higher acceleration rates. We created three reconstructions of the 3D LGE dataset using (1) ?Net , (2) a compressed‐sensing‐based low‐dimensional‐structure self‐learning and thresholding algorithm (LOST), and (3) a real‐valued U‐Net (realNet) with the same number of parameters as ?Net . LOST‐reconstructed data were considered the reference for training and evaluation of all models. The reconstructed images were quantitatively evaluated using mean‐squared error (MSE) and the structural similarity index measure (SSIM), and subjectively evaluated by three independent readers. Quantitatively, ?Net ‐reconstructed images had significantly improved MSE and SSIM values compared with realNet (MSE, 0.077 versus 0.091; SSIM, 0.876 versus 0.733, respectively; p < 0.01). Subjective quality assessment showed that ?Net ‐reconstructed image quality was similar to that of compressed sensing and significantly better than that of realNet. ?Net reconstruction was also more than 300 times faster than compressed sensing. Retrospective under‐sampled images demonstrate the potential of ?Net at higher acceleration rates. ?Net enables fast reconstruction of highly accelerated 3D MRI with superior performance to real‐valued networks, and achieves faster reconstruction than compressed sensing. 相似文献
In recent years e-liquids used in electronic cigarettes have become an attractive alternative to smoking tobacco. A new trend is the use of e-liquids containing synthetic cannabinoids (SCs) instead of smoking cannabis or herbal mixtures laced with SCs. In the frame of a systematic monitoring of the online market of ‘legal high’ products, e-liquids from online retailers who also sell herbal blends were bought.
Methods
The products were analyzed by gas chromatography-mass spectrometry. In some of the e-liquids an unknown compound was detected which was identified as the SC 5F-Cumyl-PINACA (1-(5-fluoropentyl)-N-(2-phenylpropan-2-yl)-1H-indazole-3-carboxamide) by nuclear magnetic resonance analysis. To investigate the phase I metabolism of this new class of compounds, 5F-Cumyl-PINACA and its non-fluorinated analog Cumyl-PINACA were incubated with pooled human liver microsomes (pHLM). Cumyl-PINACA was additionally ingested orally (0.6 mg) by a volunteer in a controlled self-experiment. To assess the relative potency of Cumyl-PINACA a set of SCs were characterized using a cAMP assay.
Results
Metabolism of 5F-Cumyl-PINACA and Cumyl-PINACA showed similarities with AM-2201 and JWH-018. The main metabolites were formed by hydroxylation at the N-pentyl side chain. The main metabolites detected in the volunteer’s urine sample were the same as in the pHLM assay. All SCs tested with the cAMP assay were full agonists at the CB1 receptor. Cumyl-PINACA was the most potent SC among the tested compounds and showed an EC50 value of 0.06 nM.
Conclusions
The increasing popularity of e-liquids particularly among young people, and the extreme potency of the added SCs, pose a serious threat to public health. To our knowledge, this is the first report describing the tentative identification of human in vivo metabolites of Cumyl-PINACA and 5F-Cumyl-PINACA.
Background and purpose — Motorized intramedullary lengthening nails (ILNs) have been developed as an alternative to external fixators for long bone lengthening. The antegrade approach represents the standard method for tibial ILN insertion. In patients with preexisting ankle and hindfoot fusion a retrograde approach provides an alternative technique that has not been evaluated so far. We report the outcome of this method in 10 patients.Patients and methods — This retrospective study included 10 patients (mean age 18 years [13–25]) with preexisting ankle and hindfoot fusion who underwent tibial lengthening with a retrograde ILN (PRECICE). The mean leg length discrepancy (LLD) was 58 mm (36–80). The underlying conditions were congenital (n = 9) and post tumor resection (n = 1). The main outcome measures were: ILN reliability, distraction achieved, distraction index (DIX), time to bone healing, consolidation index (CIX), complications, and functional results.Results — All patients achieved the goal of lengthening (mean 48 mm [26–80]). Average DIX was 0.6 mm/day (0.5–0.7) and mean CIX was 44 days/cm (26–60). Delayed consolidation occurred in 2 patients and healed after ILN dynamization or nail exchange with grafting. Toe contractures in 2 other patients were resolved with physiotherapy or tenotomy. Until last follow-up (mean 18 months [12–30]) no true complications were encountered, knee motion remained unaffected, and full osseous consolidation occurred in all patients.Interpretation — In patients with LLD and preexisting ankle and hindfoot fusion distal tibial lengthening using a retrograde ILN is a reliable alternative to the standard approach with equivalent bone healing potential and low complication rates leaving the knee unaffected.Fully implantable intramedullary lengthening nails (ILNs) with mechanical (Guichet and Casar 1997, Cole et al. 2001) and motorized (Baumgart et al. 1997, Schiedel et al. 2014) drive systems have been developed as an alternative to external fixators for bone lengthening (Mahboubian et al. 2012, Black et al. 2015, Laubscher et al. 2016). Recently, magnetically driven ILNs in particular have become increasingly popular (Kirane et al. 2014, Wagner et al. 2017) and in contrast to external fixation provide an equally safe and more comfortable option for limb lengthening and deformity correction (Szymczuk et al. 2019, Horn et al. 2019). Antegrade or retrograde femoral and antegrade tibial lengthening with the PRECICE limb lengthening system (NuVasive, San Diego, CA, USA) has been assessed by several studies (Kirane et al. 2014, Schiedel et al. 2014, Shabtai et al. 2014, Tiefenboeck et al. 2016, Wiebking et al. 2016, Fragomen and Rozbruch 2017, Wagner et al. 2017, Iobst et al. 2018, Cosic and Edwards 2020, Nasto et al. 2020).In tibial lengthening the antegrade approach represents the standard method for ILN implantation (Fragomen and Rozbruch 2017). In patients with preexisting ankle and hindfoot fusion a retrograde approach provides an alternative technique for tibial nail insertion. Approach-associated affections of the knee joint like anterior knee pain (Rothberg et al. 2019) and—in immature patients—damage to the proximal tibial growth plate (Wagner et al. 2017, Frommer et al. 2018) can be avoided. Despite these potential advantages, the use of a retrograde tibial nailing approach and distal tibial osteotomy in patients with preexisting ankle and hindfoot fusion has not been evaluated so far. 相似文献
Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT) and positron emission tomography (PET) studies at rest and after acetazolamide challenge. Cerebral blood flow (CBF) maps on perfusion CT resulted from a deconvolution of parenchymal time-concentration curves by an arterial input function (AIF) in the anterior cerebral artery as well as in both anterior choroidal arteries. CBF was measured by [15O]H2O PET using multilinear least-squares minimization procedure based on the one-compartment model. In corresponding transaxial PET scans, CBF values were extracted using standardized ROIs. The baseline perfusion CT-CBF values were lower in perfusion CT than in PET (P>0.05). CBF values obtained by perfusion CT were significantly correlated with those measured by PET before (P<0.05) and after (P<0.01) acetazolamide challenge. Nevertheless, the cerebrovascular reserve capacity was overestimated (P=0.05) using perfusion CT measurements. The AIF selection relative to the side of carotid stenosis did not significantly affect calculated perfusion CT-CBF values. In conclusion, the perfusion CT-CBF measurements correlate significantly with the PET-CBF measurements in chronic carotid stenotic disease and contribute useful information to the evaluation of the altered cerebral hemodynamics. 相似文献
Background and purpose — Temporary hemiepiphysiodesis for growth modulation in skeletally immature patients is a long-known technique. Recently the use of tension-band devices has become popular. This study compares 2 tension-band implants (eight-Plate and FlexTack) regarding their effects on the growth plate.Animals and methods — 12 pigs in 2 equally sized groups (A and B) were investigated. The right proximal medial tibia was treated with either eight-Plate or FlexTack. The left tibia of the same pig was treated with the opposite implant. After 9 weeks all implants were removed. Animals in group B were then hosted for another 5 weeks. Histomorphometric analysis of the growth plate was carried out after 9 and 14 weeks, respectively. Radiographs were taken at implantation, removal, and after 14 weeks.Results — Both tension-band devices achieved a statistically significant and clinically relevant growth inhibition, whereas the effect appeared to be more distinct after the use of FlexTack. Implant-related complications or physeal damage was not observed. After implant removal, rebound phenomenon was radiologically observed in all cases. The growth plates treated with eight-Plate showed a paradox reversal of the zonal distributions, with an increase of the proliferative zones at the previously arrested medial aspect of the physis and a decrease laterally.Interpretation — Both eight-Plate and FlexTack proved to be appropriate devices for growth-guiding treatment. The radiographic evaluation showed a change in angular axes after treatment with each implant, while the correction appeared to be faster with FlexTack. The paradox cartilaginous reaction observed after removal of the eight-Plate might be a histopathological correlate for rebound phenomenon.To achieve realignment of angular deformities in skeletally immature patients, remaining bone growth can be used for growth modulation procedures to avoid extensive surgical interventions (Stevens 2007). Temporary hemiepiphysiodesis (THE) aims to mechanically inhibit growth on one side of the physis through a bridging implant. The procedure has to be performed before skeletal maturity, to maintain sufficient potential for correction while also reducing the risk of relapse of the deformity after implant removal (rebound phenomenon). Blount in 1949 described a stapling technique for THE, which provided good results in the correction of angular deformities but was later linked to complications like implant failure and physeal damage (Blount and Clarke 1949, Kanellopoulos et al. 2011, Stevens 2007). In 2007 Stevens introduced a non-locking 2-hole plate (eight-Plate [EP], Orthofix Medical Inc, Lewisville, TX, USA) based on the tension-band principle (Stevens 2007). Even though treatment with the EP seems to have an overall decreased complication rate, screw breakage is still reported rather frequently (Schroerlucke et al. 2009, Burghardt et al. 2010, 2011, Scott 2012, Vogt et al. 2016). This led to the development of a flexible staple (FlexTack [FT], Merete GmbH, Berlin, Germany). Both implants, EP and FT, achieve a tension-band effect through an extra-physeally located fulcrum of correction supposedly leading to reduced compression on the physis, thus decreasing the risk of premature closure of the physis (Vogt et al. 2016). Different from the EP, the FT is a 1-piece implant with a flexible mid-zone that provides dynamic bending under bone growth force.We examined the physeal response to THE with these 2 tension-band devices and whether there is a histomorphological correlate for the extent of the blockage between FT and EP. Additionally, we sought a possible histomorphological explanation for the excessive unilateral bone growth frequently occurring after implant removal, which might be linked to the incidence of rebound phenomenon. 相似文献
ABO‐incompatible (ABOi) kidney transplantation (KTx) has become an accepted therapeutic option in renal replacement therapy for patients without a blood group‐compatible living donor. Using different desensitization strategies, most centers apply B‐cell depletion with rituximab and maintenance immunosuppression (IS) with tacrolimus and mycophenolic acid. This high load of total IS leads to an increased rate of surgical complications and virus infections in ABOi patients. Our aim was to establish ABOi KTx using an immunosuppressive regimen, which is effective in preventing acute rejection without increasing the risk for viral infections. Therefore, we selected a de novo immunosuppressive protocol with low‐dose calcineurin inhibitor and the mTOR inhibitor everolimus for our ABOi program. Here, we report the first 25 patients with a complete three‐yr follow‐up treated with this regimen. Three‐yr patient survival and graft survival were 96% and 83%. The rate of acute T‐cell‐mediated rejections was low (12%). Cytomegalovirus (CMV) infection was evident in one patient only (4%). Surgical complications were common (40%), but mild in 80% of cases. We demonstrate that ABOi KTx with a de novo mTOR inhibitor‐based regimen is feasible without severe surgical or immunological complications and a low rate of viral infections. 相似文献
Management of staghorn calculi is still a challenge. To combine the surgical principles of treatment with the minimal invasive access we performed a laparoscopic anatrophic nephrolithotomy in a female patient successfully. Patient was discharged free of stone on fifth postoperative day. No complications occurred. 相似文献