Background: Previous genome-wide association study (GWAS) has revealed the association between MYP10 at 8p23 and MYP15 at 10q21.1 and high myopia (HM) in a French population. This study is managed to discover the connection between some single nucleotide polymorphism (located at MYP10 and MYP15) and Han Chinese HM.
Methods and Results: This case-control association study contained 1673 samples, including 869 ophthalmic patients and 804 controls. Twelve tag SNPs have been selected from the MYP10 and MYP15 loci and genotyped by SNaPshot method. Among 12 SNPs, rs4840437 and rs6989782 in TNKS gene were found significant association with HM. Carriers of rs4840437G allele and rs4840437GG genotype created a low risk of high myopia (P = .036, OR = 0.81, 95%CI = 0.71–0.93; P = .016, OR = 0.73, 95%CI = 0.56–0.96; respectively). Carriers of rs6989782T allele and rs6989782TT+CT genotype also had a decreased risk of high myopia (P = .048, OR = 0.82, 95%CI = 0.71–0.94; P = .006, OR = 0.74, 95%CI = 0.59–0.92; respectively). Other 10 SNPs displaced nonsignificant association with HM. Additionally, the risk haplotype AC and the protective haplotype GT, generated by two SNPs in TNKS, were considerably more likely to be association with HM (for AC, P = .002 and OR = 1.26; for GT, P = .027 and OR = 0.84).
Conclusions: Our results demonstrated that some heritable variants in the TNKS gene are associated with HM in the Han population. The possible functions of TNKS in the development and pathogenesis of hereditary high myopia still require further researches to identify. 相似文献
Bulletin of Environmental Contamination and Toxicology - In this study, a composite algaecide containing flocculants and Cinnamomum. camphora leaves extracts (CCCLE) were synthesized. The... 相似文献
AbstractBackground and aim: Capsule retention is the most common adverse event associated with video capsule endoscopy. The use of double-balloon enteroscopy-assisted capsule endoscope retrieval has been increasingly reported in recent years. However, evidence is limited regarding its success rate, associated factors, and subsequent clinical outcomes.Methods: A systematic review of relevant studies published before January 2019 was performed. Successful retrieval rate and associated factors, rate of endoscopic balloon dilation, and outcomes after double-balloon enteroscopy were summarized and pooled.Results: Within 154 associated original articles, 12 including 150 cases of capsule retrieval by double-balloon enteroscopy were included. The estimated pooled successful retrieval rate was 86.5% (95% confidence interval, 75.6–95.1%). Anterograde approach and capsules retained in the jejunum or trapped by malignant strictures were associated with a higher successful retrieval rate than the retrograde approach (62/83 [74.7%] vs. 10/38 [26.3%], p?<?.001) and capsules retained in the ileum (41/41 [100.0%] vs. 43/58 [74.1%], p?<?.001) or trapped by benign strictures (21/21 [100.0%] vs. 65/83 [78.3%], p?=?.043). Endoscopic balloon dilation was performed in 38.8% (95% confidence interval, 22.3–56.3%) of patients with benign strictures. Two perforations (1.3%) were reported as severe adverse events after double-balloon enteroscopy. A significantly lower surgery rate was found among cases with successful video capsule removal compared with unsuccessful cases (7.2% vs. 38.5%, p?=?.002).Conclusions: Double-balloon enteroscopy is feasible and safe for removing retained video capsule endoscopes, and its use could decrease the need for surgery in patients with benign strictures and facilitate subsequent surgery in patients with malignant strictures. 相似文献