166Ho-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetramethylene-phosphonate (DOTMP) is a tetraphosphonate molecule radiolabeled with 166Ho that localizes to bone surfaces. This study evaluated pharmacokinetics and radiation-absorbed dose to all organs from this beta-emitting radiopharmaceutical. METHODS: After two 1.1-GBq administrations of 166Ho-DOTMP, data from whole-body counting using a gamma-camera or uptake probe were assessed for reproducibility of whole-body retention in 12 patients with multiple myeloma. The radiation-absorbed dose to normal organs was estimated using MIRD methodology, applying residence times and S values for 166Ho. Marrow dose was estimated from measured activity retained after 18 h. The activity to deliver a therapeutic dose of 25 Gy to the marrow was determined. Methods based on region-of-interest (ROI) and whole-body clearance were evaluated to estimate kidney activity, because the radiotracer is rapidly excreted in the urine. The dose to the surface of the bladder wall was estimated using a dynamic bladder model. RESULTS: In clinical practice, gamma-camera methods were more reliable than uptake probe-based methods for whole-body counting. The intrapatient variability of dose calculations was less than 10% between the 2 tracer studies. Skeletal uptake of 166Ho-DOTMP varied from 19% to 39% (mean, 28%). The activity of 166Ho prescribed for therapy ranged from 38 to 67 GBq (1,030-1,810 mCi). After high-dose therapy, the estimates of absorbed dose to the kidney varied from 1.6 to 4 Gy using the whole-body clearance-based method and from 8.3 to 17.3 Gy using the ROI-based method. Bladder dose ranged from 10 to 20 Gy, bone surface dose ranged from 39 to 57 Gy, and doses to other organs were less than 2 Gy for all patients. Repetitive administration had no impact on tracer biodistribution, pharmacokinetics, or organ dose. CONCLUSION: Pharmacokinetics analysis validated gamma-camera whole-body counting of 166Ho as an appropriate approach to assess clearance and to estimate radiation-absorbed dose to normal organs except the kidneys. Quantitative gamma-camera imaging is difficult and requires scatter subtraction because of the multiple energy emissions of 166Ho. Kidney dose estimates were approximately 5-fold higher when the ROI-based method was used rather than the clearance-based model, and neither appeared reliable. In future clinical trials with 166Ho-DOTMP, we recommend that dose estimation based on the methods described here be used for all organs except the kidneys. Assumptions for the kidney dose require further evaluation. 相似文献
Vacuum-assisted closure (VAC), although a modern adjunct in wound management, has not been used previously in pyoderma gangrenosum (PG), probably to avoid the potential complications of ‘pathergy’. We would like to report our experience of VAC in three cases of PG with the relevant review of literature. 相似文献
PURPOSE: The variable-pitch pulse oximeter is an important intraoperative patient monitor. Our ability to hear its auditory signal depends on its acoustical properties and our hearing. This study quantitatively describes the audio spectrum and sound pressure levels of the monitoring tones produced by five variable-pitch pulse oximeters. METHODS: We compared the Datex-Ohmeda Capnomac Ultima, Hewlett-Packard M1166A, Datex-Engstrom AS/3, Ohmeda Biox 3700, and Datex-Ohmeda 3800 oximeters. Three machines of each of the five models were assessed for sound pressure levels (using a precision sound level meter) and audio spectrum (using a hanning windowed fast Fourier trans-form of three beats at saturations of 99%, 90%, and 85%). RESULTS: The widest range of sound pressure levels was produced by the Hewlett-Packard M1166A (46.5 +/- 1.74 dB to 76.9 +/- 2.77 dB). The loudest model was the Datex-Engstrom AS/3 (89.2 +/- 5.36 dB). Three oximeters, when set to the lower ranges of their volume settings, were indistinguishable from background operating room noise. Each model produced sounds with different audio spectra. Although each model produced a fundamental tone with multiple harmonic overtones, the number of harmonics varied with each model; from three harmonic tones on the Hewlett-Packard M1166A, to 12 on the Ohmeda Biox 3700. There were variations between models, and individual machines of the same model with respect to the fundamental tone associated with a given saturation. CONCLUSION: There is considerable variance in the sound pressure and audio spectrum of commercially-available pulse oximeters. Further studies are warranted in order to establish standards. 相似文献
The use of vacuum assisted closure (V.A.C.) therapy in postoperative infections after dorsal spinal surgery was studied retrospectively. Successful treatment was defined as a stable healed wound that showed no signs of acute or chronic infection. The treatment of the infected back wounds consisted of repeated debridement, irrigation and open wound treatment with temporary closure by V.A.C. The instrumentation was exchanged or removed if necessary. Fifteen patients with deep subfascial infections after posterior spinal surgery were treated. The implants were exchanged in seven cases, removed completely in five cases and left without changing in one case. In two cases spinal surgery consisted of laminectomy without instrumentation. In two cases only the wound defects were closed by muscle flap, the remaining ones were closed by delayed suturing. Antibiotic treatment was necessary in all cases. Follow up was possible in 14 patients. One patient showed a new infection after treatment. The study illustrates the usefulness of V.A.C. therapy as a new alternative management for wound conditioning of complex back wounds after deep subfascial infection. 相似文献
Background: Previous studies have shown that propofol and sevoflurane enhance the function of [gamma]-aminobutyric acid type A (GABAA) receptors. However, it is not known whether these two drugs modulate the same molecular pathways. In addition, little is known about receptor function in the presence of both propofol and sevoflurane. The aim of this study was to better understand the interactions of propofol and sevoflurane with the GABAA receptor.
Methods: Wild-type [alpha]1, [beta]2, [gamma]2s GABAA receptor subunit complementary DNAs were transfected into human embryonic kidney cells grown on glass coverslips using a calcium phosphate transfection method. After transfection (36-72 h), cells were whole cell patch clamped and exposed to combinations of the following: 0.3-1,000 [mu]m [gamma]-aminobutyric acid (GABA), 0-10 [mu]m propofol, and 0-1,650 [mu]m sevoflurane. Chemicals were delivered to the cells using two 10-channel infusion pumps and a rapid solution exchanger.
Results: Both propofol and sevoflurane alone enhanced the amplitude of GABAA receptor responses to submaximal concentrations of GABA in a dose-dependent manner. The enhancement was underpinned by an increase in the apparent affinity of the receptor for GABA. Coapplication of both anesthetics further enhanced the apparent affinity of the receptor for GABA. 相似文献
Herniography has been used for 25 years in the diagnosis of occult herniation but has not gained widespread acceptance in
the UK, despite studies confirming its high sensitivity and specificity for occult hernias and an excellent record of safety
and patient acceptability. The traditional approach in the UK to suspected occult groin herniation has been surgical exploration.
This study examined the use of herniography in a single district general hospital to assess its impact in limiting unnecessary
groin explorations and allowing discharge of patients without hernias. The case notes of 90 successive patients referred for
herniography by the department of general surgery in a single UK district general hospital over an 18-month period were reviewed.
Eighty-seven completed examinations were analysed in which 23 hernias were diagnosed in 20 patients. Thirteen patients have
undergone hernia repair with resolution of symptoms. There were no false positive examinations, although two inguinal hernias
were incorrectly diagnosed radiologically as femoral hernias; there were two false negative examinations where additional
hernias were found at laparoscopic repair. There were no reported complications. Twenty-four patients were discharged directly
from the surgical clinic after a negative herniogram. Thirty patients were referred to other specialities. No patient had
undergone groin exploration after a negative herniogram. Herniography is a useful tool in assessing obscure groin pain and
potential occult herniation. It can reliably rule out the presence of a hernia and avoid the need for surgical exploration.
Many patients with a negative herniogram can be reassured and discharged, whilst others may be referred on to other specialities
safe in the knowledge that an occult hernia has been excluded. 相似文献
AIMS: To report clinical outcomes of a large series of cases with advanced thyroid cancer. STUDY DESIGN: Three hundred and eighty-five patients at the UICC stages III and IV were selected for the study with thyroid cancer. RESULTS: Papillary carcinoma and sclerosing carcinoma have better survival than the Hürthle cell and insular types. Lymphatic metastasis does not appear to worsen the prognosis. All the tumour forms offer the chance of long survival. CONCLUSIONS: Surgical treatment is the primary treatment of thyroid carcinoma. The combined treatments of surgery, metabolic beam therapy, suppressive hormone therapy, radiotherapy and chemotherapy cure a high percentage of patients with the tumour at an advanced stage. 相似文献
There are no data available combining transbronchial needle aspiration (TBNA) of mediastinal lymph nodes and positron emission tomography (PET) in the staging of nonsmall cell lung cancer (NSCLC). The aim of the current study was to determine if these two methods can enhance the negative predictive value of the individual modality alone, for a specific lymph node station, and if this integrated approach can reduce the number of mediastinoscopies. A total of 113 patients with enlarged mediastinal lymph nodes (> or = 1 cm), who underwent both TBNA and PET scanning, were included. In 51 patients, histopathology, confirmed by surgical lymph node dissection, was compared with PET results and TBNA. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy to detect malignant lymphadenopathy was 68 (13/19), 89 (119/134), 46 (13/28), 95 (119/125) and 86% (132/152) for PET, respectively; 54% (6/11), 100 (53/53), 100 (6/6), 91 (53/58) and 92% (59/64), respectively for TBNA; and 100 (11/11), 94 (50/53), 79 (11/14), 100 (50/50) and 95 (61/64) for combined TBNA and PET, respectively. Combination of transbronchial needle aspiration and positron emission tomography has the potential to allow adequate mediastinal staging of nonsmall cell lung cancer with enlarged lymph nodes in most patients without the need for mediastinoscopy. 相似文献