Background. We developed a method of closed-chest cardiopulmonary bypass to arrest and protect the heart with cardioplegic solution. This method was used in 54 dogs and the results were retrospectively analyzed.
Methods. Bypass cannulas were placed in the right femoral vessels. A balloon occlusion catheter was passed via the left femoral artery and positioned in the ascending aorta. A pulmonary artery vent was placed via the jugular vein. In 17 of the dogs retrograde cardioplegia was provided with a percutaneous coronary sinus catheter.
Results. Cardiopulmonary bypass time was 111 ± 27 minutes (mean ± standard deviation) and cardiac arrest time was 66 ± 21 minutes. Preoperative cardiac outputs were 2.9 ± 0.70 L/min and postoperative outputs were 2.9 ± 0.65 L/min (p = not significant). Twenty-one-French and 23F femoral arterial cannulas that allowed coaxial placement of the ascending aortic balloon catheter were tested in 3 male calves. Line pressures were higher, but not clinically limiting, with the balloon catheter placed coaxially.
Conclusions. Adequate cardiopulmonary bypass and cardioplegia can be achieved in the dog without opening the chest, facilitating less invasive cardiac operations. A human clinical trial is in progress. 相似文献
Critically ill patients are usually in a catabolic state and may require total parenteral nutrition; this often includes lipid emulsions. Any adverse effects of constituents on pulmonary function, white cell function or the haemocoagulation system could have disastrous consequences in such patients. We have investigated the effects of a new intravenous lipid preparation containing medium chain triglycerides, which, in severely ill malnourished patients are theoretically a preferable energy source to conventional drug chain triglycerides. In a pilot study 17 critically ill patients whose lungs were artificially ventilated were given this lipid emulsion; no adverse effects were observed. Arterial oxygen and carbon dioxide tensions, ratio of inspired oxygen fractional concentration to arterial oxygen tension, platelet and white cell counts all remained constant and the complement system was not activated. 相似文献
A multiple-center study was performed to determine the relationship between lower esophageal contractility, clinical signs, and anesthetic concentration as expressed by minimum alveolar concentration (MAC). One hundred four American Society of Anesthesiologists Class I through III patients were exposed to isoflurane (with and without nitrous oxide) or halothane in concentrations of 0.5, 1.0, and 1.5 MAC. Heart rate and systolic blood pressure were continuously monitored. Both the amplitude and frequency of spontaneous and provoked lower esophageal contractions were measured in situ by using a 24-F probe equipped with provoking and measuring balloons. Combined results demonstrated statistically significant correlations (P<0.001) between lower esophageal contractility and MAC. Spontaneous lower esophageal contractions decreased from 1.10±0.12 (SEM) contractions per minute (0.5 MAC) to 0.42±0.05 (1 MAC) to 0.18±0.05 (1.5 MAC). Provoked lower esophageal contractility values decreased from 45±4 mm Hg (0.5 MAC) to 29±3 (1 MAC) to 19±2 (1.5 MAC). Heart rate changes did not correlate with MAC, and systolic blood pressure correlated in only one of three centers. Intracenter and intercenter analyses failed to demonstrate a significant relationship between lower esophageal contractility and heart rate or systolic blood pressure. No intracenter differences in either amplitude or frequency of lower esophageal contractions were observed, despite differences in volatile agents, induction techniques and agents, patient populations, and duration of anesthesia. Our studies indicate that lower esophageal contractility may be an indicator of anesthetic depth as reflected by MAC, but further studies are needed to quantify the effects of surgical stimulus, intravenous anesthetics, vasodilators, anticholinergics, calcium channel blockers, beta-adrenergic agonists, and the presence of a nasogastric tube. 相似文献
The growth of bioscience knowledge over the last two decades has increased the potential benefits of scientifically based patient care by contributing to the theory of clinical care. However, there is little evidence that knowledge, derived from the human biosciences is being fully incorporated into nursing theory and practice.Nursing has developed its own unique professional body of knowledge, heavily influenced by behavioural science. If nursing theory leans towards behavioural science, but practice is devoted to problems of biological disturbance, nursing may be facing a widening theory-practice gap, greater than other professions. The theory-practice gap in nursing may be widened by the exclusion of bioscience from nursing theory. Nurses' relative disinterest in the natural sciences can be attributed both to sociological reasons and to problems stemming from the symbol-object dichotomy that recur in the teaching of natural sciences. Reflection on practice and examination of education method are suggested as strategies for re-introducing bioscience into nursing theory and practice. A challenge facing nurse educators is the integration of biological science into the nurses' conceptual ecologies. For, if nursing fails to make bioscience its own, much of the clinical welfare of patients will become a medical monopoly. 相似文献
A retrospective study was carried out to determine the relationship between parity and bone mineral density (BMD) in middle-aged women. Eight hundred and twenty-five woman aged 41–76 years were recruited from four general practice registers in Cambridge. Subjects were unselected as to their health status. Each subject completed a detailed health questionnaire. Participation rate was 50%. The main outcome measure was BMD measured at the spine (L2–4,n=825) and hip (neck, intertrochanter and Ward's triangle;n=817) by dual-energy X-ray absorptiometry (DXA) using the Hologic QDR-1000 densitometer. It was found that the unadjusted mean BMD was significantly higher at all sites among the parous women (p=0.031 to <0.00001), and remained significantly higher at the femoral neck (p=0.025), intertrochanter (p=0.001) and Ward's triangle (p=0.045) after adjusting for age and body mass index (BMI). Similar findings were seen after stratifying for potential confounding variables. There was a consistent upward trend of BMD with increasing parity at all sites. Parity remained a significant independent predictor of BMD at all sites after controlling for age, BMI, menopausal status, oral contraceptive and hormone replacement therapy use, smoking status and breast-feeding status in multiple linear regression analyses. There was, on average, a 1.0% increase in BMD per live birth. Our findings therefore suggest a positive relationship between parity and bone mass. 相似文献