Background: Postoperative nausea and vomiting (PONV) is a distressing problem after strabismus surgery. An inspired oxygen fraction has been reported to decrease PONV in patients after colon resection and to be more effective than ondansetron after gynecologic laparoscopy. Therefore, in a randomized, prospective, placebo-controlled study, the authors tested whether an inspired oxygen fraction of 0.8 decreases PONV in patients undergoing strabismus surgery and whether oxygen is more effective than ondansetron.
Methods: With approval of the authors' institutional review board, 210 patients were randomly assigned to receive one of three treatments: (1) 30% inspired oxygen in air plus intravenous administration of saline, (2) 80% inspired oxygen in air plus intravenous administration of saline, or (3) 30% inspired oxygen in air plus 75 [mu]g/kg ondansetron intravenously during induction. General anesthesia was standardized and included etomidate, alfentanil, and mivacurium for induction and sevoflurane for maintenance. PONV was evaluated 6 and 24 h postoperatively by an investigator unaware of treatment assignment.
Results: Overall postoperative incidence of nausea and vomiting was 41% for inspired oxygen fraction of 0.3 plus placebo, 38% for inspired oxygen fraction of 0.8 plus placebo, and 28% for inspired oxygen fraction of 0.3 plus ondansetron, respectively (P = 0.279). Therefore, there was no statistically significant difference of PONV incidence among groups. 相似文献
Abstract
Dealing with pediatric fracture patients requires a funded knowledge of complications and remodeling capability of the youth skeleton to find the accurate therapy decision and to avoid unnecessary invasive procedures. Due to the different mechanical environment, fractures in children occur at specific fracture-vulnerable areas. One of those is the growth plate, which on one hand gives rise to the unique ability of correcting angular deformities by specifically increasing the growth rate in definite regions, and on the other hand leads to complications like growth arrest or angular deformity. The pediatric diaphysis presents the exclusive greenstick fracture, only seen in the growing skeleton, which occurs because of the different composition of the pediatric bone. To understand these very specific features of the youth skeleton, the molecular and cellular basis should be taken into consideration. Therefore, this review will present the common characteristics of skeletal development and fracture healing. An insight into the mechanotransduction as part of the remodeling and self-correcting ability of pediatric bone is given to span the bridge between clinical treatment options and scientific background. 相似文献
Longterm outcomes after valgization high tibial osteotomy (HTO) to treat varus osteoarthritis seem to depend mainly on correction precision. Intraoperative assessment of leg alignment based on radiological visualization of the mechanical axis is difficult and its precision is limited. A promising approach to improving precision is to make use of navigation systems. The case–control study reported here involved the evaluation of patients whose varus osteoarthritis had been treated by open-wedge high tibial ostoetomy, and an analysis of the effect of computer-guided navigation on postoperative leg alignment.
Methods
Forty patients with medial varus osteoarthritis managed by open-wedge high tibial osteotomy using a surgical navigation system were included in the present study (Group 1). They were compared with a retrospective control group (Group 2) of 40 patients with respect to postoperative leg alignment, correlation of planned and definitive correction, and postoperative deviation from the Fujisawa point.
Results
The mean values for planned and definitive correction showed no significant differences for identical demographic data. As a percentage of the width of the tibial plateau the postoperative weight-bearing radiographs showed a mechanical line that intersected with the knee base line at the desired value of 62 % (Fujisawa point) in 58.8 % (SD ± 6.1) in Group 1 and in 58.6 % (SD ± 8.1) in Group 2. Despite similar mean values a significantly higher number of corrections were outside the reference area (n = 7) in the non-navigated group, whereby all corrections were within the desired range in the navigated group. There were no significant differences in operation time.
Conclusions
This study showed that the use of a navigation system can not increase the precision of the open-wedge HTO procedure in patients with varus osteoarthritis but it can eliminate the outliers of a well defined range.
Level of evidence
Case-control study, Retrospective comparative study, Level III. 相似文献
Due to intimal hyperplasia instent reobstruction in the femoropopliteal arterial segment is still an unsolved problem. Different techniques have been discussed in case of reintervention to guarantee longlasting patency rate.
Methods
We conducted a randomized, controlled, pilot trial comparing Silverhawk atherectomy with percutaneous transluminal angioplasty (PTA) in patients with a first instent reobstruction in the femoropopliteal arterial segment, to evaluate intima media thickness (IMT) within the treated segment, as a parameter of recurrence of intimal hyperplasia.
Results
In a total 19 patients were included: 9 patients in the atherectomy device and 10 patients in the PTA arm. IMT within the treated segment was statistically significantly elevated in all patients treated with the Silverhawk device versus the patients treated with PTA. The obvious differentiation in elevation of IMT in nonfavor for patients treated with the Silverhawk device started at month 2 (max IMT SH 0.178 mm vs. IMT PTA 0.1 mm, p = 0.001) with a spike at month 5 (max IMT SH 0.206 mm vs. IMT PTA 0.145 mm, p = 0.003) and a decline once again at month 6 (max IMT SH 0.177 mm vs. IMT PTA 0.121 mm, p = 0.02). The values for mean IMT performed the same way.
Conclusions
Although Silverhawk atherectomy provides good results at first sight, in the midterm follow-up of treatment of first instent restenosis it did not perform better than PTA as it showed elevated reoccurrence of intimal media hyperplasia. 相似文献
IntroductionDeveloping positron emission tomography (PET) radiotracers for non-invasive study of the cholinergic system is crucial to the understanding of neurodegenerative diseases. Although several acetylcholinesterase (AChE) PET tracers radiolabeled with carbon-11 exist, no fluorinated radiotracer is currently used in clinical imaging studies. The purpose of the present study is to describe the first fluorinated PET radiotracer for this brain enzyme.MethodsThree structural analogs of huprine, a specific AChE inhibitor presenting high affinity towards AChE in vitro, were synthesized and labeled with fluorine-18 via a mesylate/fluoro-nucleophilic aliphatic substitution: ([18 F]-FHUa, [18 F]-FHUb and [18 F]-FHUc). Initial biological evaluation included in vitro autoradiography in rat with competition with an AChE inhibitor at different concentrations, and microPET-scan on anesthetized rats. In vivo PET studies in anesthetized cat focused on [18 F]-FHUa.Results and ConclusionsAlthough radiosynthesis of these huprine analogs was straightforward, they showed poor brain penetration potential, partially reversed after pharmacological inhibition of P-glycoprotein. These results indicated that current huprine analogs are not suitable for PET mapping of brain AChE receptors, but require physicochemical modulation in order to increase brain penetration. 相似文献
The purpose of this study was to test whether the acquisition of positron emission tomography (PET) does interfere with simultaneous diffusion weighted imaging (DWI) in an integrated whole-body PET/MRI system.
Material and methods
Fourteen consecutive oncological patients (9 men, 5 women; age 54 ± 13 years ([mean ± standard deviation]) scheduled for routine [18F]-FDG PET/CT were prospectively enrolled. For DWI, an echo planar imaging (EPI) sequence (b = 0–500–1000 s/mm2) was acquired twice on an integrated whole-body 3 T PET/MRI system in each patient; first with simultaneous PET acquisition and a second time with the PET component switched off. The apparent diffusion coefficient (ADC) and the signal-to-noise ratio at b = 1000 s/mm2 (SNR) of the myocardium, paraspinal muscle, liver, spleen, renal cortex and tumor tissue (if present) were measured. In addition, the coefficient of variation (CV) of ADC values was calculated. Student's t-test for paired samples was performed to test for differences of the mean ADC, ADC CV and SNR between DWI with and without simultaneous PET acquisition.
Results
There were no significant differences of the ADC [(mean ± standard deviation)] between the DWI acquisitions with and without simultaneous PET acquisition for the myocardium (2572 ± 441 × 10−6 mm2/s and 2586 ± 376 × 10−6 mm2/s, respectively) (P = 0.817), paraspinal muscle (1279 ± 254 × 10−6 mm2/s vs. 1219 ± 181 × 10−6 mm2/s) (P = 0.318), liver (1245 ± 158 × 10−6 mm2/s vs. 1254 ± 171 × 10−6 mm2/s) (P = 0.848), spleen (980 ± 122 × 10−6 mm2/s vs. 1000 ± 187 × 10−6 mm2/s) (P = 0.676) and renal cortex (1951 ± 226 × 10−6 mm2/s vs. 1930 ± 273 × 10−6 mm2/s) (P = 0.730). Mean ADC of lymph node metastases (n = 6) did not differ between with PET acquisition (853 ± 174 × 10−6 mm2/s) and without simultaneous PET (865 ± 170 × 10−6 mm2/s) (P = 0.675). There were no significant differences between the CV of ADC values or the SNR values measured in DWI datasets that were acquired with or without simultaneous PET for any evaluated organ site.
Conclusion
The simultaneous acquisition of DWI and PET on an integrated PET/MRI system does not impact ADC quantification of normal and tumor tissue and does not alter SNR. This knowledge provides a basis for the use of simultaneous multiparametric PET/MRI comprising DWI in diagnostic imaging and quantitative tumor therapy monitoring using repeated ADC measurements. 相似文献
To use the acquisition of the k‐space center signal (DC signal) implemented into a Cartesian three‐dimensional (3D) FLASH sequence for retrospective respiratory self‐gating and, thus, for the examination of the whole human lung in high spatial resolution during free breathing.
Materials and Methods:
Volunteer as well as patient measurements were performed under free breathing conditions. The DC signal is acquired after the actual image data acquisition within each excitation of a 3D FLASH sequence. The DC signal is then used to track respiratory motion for retrospective respiratory gating.
Results:
It is shown that the acquisition of the DC signal after the imaging module can be used in a 3D FLASH sequence to extract respiratory motion information for retrospective respiratory self‐gating and allows for shorter echo times (TE) and therefore increased lung parenchyma SNR.
The purpose of this phase III clinical trial was to compare two different extracellular contrast agents, 1.0 M gadobutrol
and 0.5 M gadopentate dimeglumine, for magnetic resonance imaging (MRI) in patients with known or suspected focal renal lesions.
Using a multicenter, single-blind, interindividual, randomized study design, both contrast agents were compared in a total
of 471 patients regarding their diagnostic accuracy, sensitivity, and specificity to correctly classify focal lesions of the
kidney. To test for noninferiority the diagnostic accuracy rates for both contrast agents were compared with CT results based
on a blinded reading. The average diagnostic accuracy across the three blinded readers (‘average reader’) was 83.7% for gadobutrol
and 87.3% for gadopentate dimeglumine. The increase in accuracy from precontrast to combined precontrast and postcontrast
MRI was 8.0% for gadobutrol and 6.9% for gadopentate dimeglumine. Sensitivity of the average reader was 85.2% for gadobutrol
and 88.7% for gadopentate dimeglumine. Specificity of the average reader was 82.1% for gadobutrol and 86.1% for gadopentate
dimeglumine. In conclusion, this study documents evidence for the noninferiority of a single i.v. bolus injection of 1.0 M
gadobutrol compared with 0.5 M gadopentate dimeglumine in the diagnostic assessment of renal lesions with CE-MRI.
To evaluate the potential of 11C‐choline‐positron emission tomography (PET)/computed tomography (CT) for planning surgery in patients with prostate cancer and prostate‐specific antigen (PSA) relapse after treatment with curative intent.
PATIENTS AND METHODS
We retrospectively reviewed the charts of 10 patients with PSA recurrence after either external beam radiation (two) or radical retropubic prostatectomy (eight) for prostate cancer, and who had a laparoscopic lymphadenectomy for suspicious lymph nodes detected on 11C‐choline‐PET/CT. The histological results and PET/CT findings were compared.
RESULTS
In all, 22 suspicious lymph nodes were found on PET/CT, and 14 on conventional CT or magnetic resonance imaging. Comparing the conventional imaging showed concordance in 13 lymph nodes. Three of the 10 patients had no metastatic lymph node disease on definitive histology. The mean (sd ) PSA level for these patients was 1.0 (0.4) ng/mL, whereas that in patients with lymph node metastases was 15.1 (9.2) ng/mL (statistically significant difference, P < 0.05). The positive predictive value was seven of 10. All of the patients initially regressed, with PSA increases after lymphadenectomy. Two of the patients are being managed by watchful waiting, two had radiotherapy of the prostate fossa and two had chemotherapy with docetaxel. Four patients were treated by hormone‐deprivation therapy. After a mean (sd ) follow up of 11 (7) months, one patient died, one has PSA progression, but none of those with negative histology has clinical signs of local recurrence.
CONCLUSIONS
11C‐choline‐PET is a valuable tool for detecting recurrent prostate cancer, but the limited positive predictive value should lead to a critical interpretation of the results. 相似文献