The study described tested the hypothesis that increasing amounts of dietary fibre (DF) in the diet of patients on haemodialysis (HD) may achieve positive clinical benefit without adversely affecting serum potassium and plasma phosphate. The current diet of 20 home HD patients was supplemented with 15g unprocessed wheat bran incorporated into three 'bran muffins' eaten daily for a trial period of 28 days. During this period patients reported an improvement in bowel habit. Serum potassium decreased slightly but not significantly ( P =0.242) but there was a significant rise in plasma phosphate ( P =0.004). These findings suggest that when increasing DF in devising HD dietary regimes, plasma phosphate is possibly the more sensitive biochemical variable following introduction of wheat bran. 相似文献
Pneumococcal diseases remain a major cause of morbidity and mortality worldwide. Updated data on drug-resistance from different
populations may be important to recognize changes in disease patterns. This study assessed current levels of penicilin resistance
among Streptococcus Pneumoniae causing pneumonia in Spanish middle age and older adults. 相似文献
Background: The analgesic nefopam does not compromise ventilation, is minimally sedating, and is effective as a treatment for postoperative shivering. The authors evaluated the effects of nefopam on the major thermoregulatory responses in humans: sweating, vasoconstriction, and shivering.
Methods: Nine volunteers were studied on three randomly assigned days: (1) control (saline), (2) nefopam at a target plasma concentration of 35 ng/ml (low dose), and (3) nefopam at a target concentration of 70 ng/ml (high dose, approximately 20 mg total). Each day, skin and core temperatures were increased to provoke sweating and then reduced to elicit peripheral vasoconstriction and shivering. The authors determined the thresholds (triggering core temperature at a designated skin temperature of 34[degrees]C) by mathematically compensating for changes in skin temperature using the established linear cutaneous contributions to control of each response.
Results: Nefopam did not significantly modify the slopes for sweating (0.0 +/- 4.9[degrees]C [middle dot] [mu]g-1 [middle dot] ml; r2 = 0.73 +/- 0.32) or vasoconstriction (-3.6 +/- 5.0[degrees]C [middle dot] [mu]g-1 [middle dot] ml; r2 = -0.47 +/- 0.41). In contrast, nefopam significantly reduced the slope of shivering (-16.8 +/- 9.3[degrees]C [middle dot] [mu]g-1 [middle dot] ml; r2 = 0.92 +/- 0.06). Therefore, high-dose nefopam reduced the shivering threshold by 0.9 +/- 0.4[degrees]C (P < 0.001) without any discernible effect on the sweating or vasoconstriction thresholds. 相似文献
Universally applied standards for administering radiopharmaceutical doses in children do not presently exist. Hence, pediatric radiopharmaceutical dosimetry varies considerably from institution to institution and is generally based on the recommended adult dose adjusted for body mass. METHODS: We surveyed 13 pediatric hospitals in North America to obtain objective data on dosimetry practices for 16 pediatric nuclear medicine examinations, including the minimum total radiopharmaceutical administered dose per examination, the total administered dose based on body mass, and maximum total doses in children. RESULTS: The reported administered doses of radiopharmaceuticals to children vary over a relatively large range, especially with respect to minimum total administered doses. CONCLUSION: This survey has identified a broad range of administered doses directly leading to variability in radiation-absorbed doses to patients. The nuclear medicine community should develop pediatric standards for radiopharmaceutical administered doses and reduce radiation exposure in children, such as through the use of modern software reconstruction techniques. 相似文献
Background: A quantitative scale of intubation difficulty would be useful for objectively comparing the complexity of endotracheal intubations. The authors have developed a quantitative score that can be used to evaluate intubating conditions and techniques with the aim of determining the relative values predictive factors of intubation difficulty and of the techniques used to decrease such difficulties.
Methods: An Intubation Difficulty Scale (IDS) was developed, based on parameters known to be associated with difficult intubation. It was then evaluated prospectively in a group of 311 consecutive prehospital intubations and 315 intubations in an operating room. In the operating room, the IDS was compared with two other parameters: the time to completion of intubation and the visual analog scale (VAS). Time was measured by an independent observer. Operators in both groups completed a checklist regarding the conditions of intubation.
Results: There is a good correlation between the IDS scale and the VAS assessment of difficulty and time to completion of intubation. VAS and time to completion have a significant but lesser correlation to each other. Comparison of IDS with operator-assessed subjective categorical impression of difficulty by Kruskall-Wallis was statistically significant. 相似文献
The purposes of this investigation were to standardize and validate a simple quantitative method for performing radionuclide solid gastric emptying that can be used for any dual-head gamma-camera and to establish reference values. METHODS: After eating a solid meal (egg sandwich) labeled with a radionuclide, 20 healthy volunteers (9 male, 11 female) underwent a 90-min gastric-emptying study performed with a triple-head gamma-camera. Two sets of 3 simultaneous projections were acquired sequentially for 30 s each: anterior, right posterior oblique (RPO), left posterior oblique (LPO), posterior, left anterior oblique (LAO), and right anterior oblique (RAO), and this sequence was repeated continuously for 90 min. Time-activity curves were generated using a gastric region of interest for each of the views as well as the conjugate-view geometric mean (GM) data for the anterior/posterior, LAO/RPO, and RAO/LPO combinations. Quantitative parameters were determined: percentage gastric emptying (%GE) at 90 min, half-time (min) based on an exponential fit, and clearance rate (%/min) based on a linear fit. Reference values were determined on the basis of a 95% confidence interval of the t distribution. The results were statistically analyzed and compared. RESULTS: The %GE reference values were greater for the anterior/posterior GM (>or=33%) than for the LAO (>or=31%) and anterior (>or=30%) GMs. The 3 %GE GM methods, the 3 exponential-fit GM methods, and the 3 linear-fit GM methods had high correlation coefficients (r >or= 0.874), and with only a single exception, there was no statistical difference among them. The LAO method and LAO/RPO GM mean method correlated strongly (r = 0.900) and had similar mean values (52% vs. 51%) and reference values (29% vs. 30%). All 3 methods of GM quantification also correlated strongly, and there was no significant difference among them. CONCLUSION: We have described and validated a simple method for radionuclide solid gastric emptying that can be used with a dual-head gamma-camera. We recommend the anterior/posterior GM method and have established reference values (>or=33%). 相似文献
Magnetic resonance imaging enhanced with a macromolecular contrast medium (MMCM), albumin-Gd-DTPA, was used to estimate the plasma volume in vivo in the myocardium, lung, liver, and skeletal muscle of 10 normal rats. The plasma volumes of the same tissues in a parallel group of six rats were estimated in vitro by a conventional radioisotopic technique (111In-transferrin). Plasma volumes of myocardium, lung, liver, and skeletal muscle estimated by the MR technique (μl plas. ia cc-1 of tissue) were 101,109,163, and 11.0, respectively, while plasma volumes measured by the In-transferrin radioisotope technique (mg plasma g-1 of tissue) were 78.6, 215,143, and 11-2, respectively. Assuming a ratio of densities of aerated lung to blood of 0.45 and of other tissues to blood of 1.0, correlation between the methods was excellent (R2 = 0.99) indicating that MR imaging enhanced with MMCM permits reliable in vivo estimation of tissue plasma volume in the rat. 相似文献
The authors have established a new method for extraction and determination of atracurium in human plasma that employs a reversed phase high-performance liquid chromatography (HPLC). This method made use of a fluorescent spectrophotometer at an excitation wavelength of 240nm and an emission wavelength of 310nm. The mobile phase was made of a phosphate buffer, distilled water and acetonitrile (20V:30V:50V). The analytical column used was a Little Champ C18.In a Bond Elute C18 extraction column, which had been prewashed with a phosphate buffer and a 50% methanol solution, atracurium was extracted from acidified plasma samples using a mixture of methanol and phosphate buffer. A standard curve was prepared by the internal standard method using metocurine. A high linear correlation between atracurium concentration and the ratio of the atracurium peak height to the metocurine peak height was observed (r = 0.9994). The lowest threshold for detection of atracurium was 15ng/ml. When the plasma concentrations of atracurium were determined in 2 clinical cases, t1/2 was 2.10 and 1.73min and t1/2 was 15.57 and 21.57min, respectively. These results indicate that this method of extraction and determination is appropriate for studying the pharmacokinetics of atracurium because it allows a high reproducibility, and provides an extremely accurate, simple and quick analysis.(Okutani R, Kono K, Frederic M. deBros et al.: Quantitative determination of atracurium in human plasma using high-performance liquid chromatography. J Anesth 2: –, 1988) 相似文献