Background. Little is known about preload-dependent cardiac function after brain death (BD) and subsequent graft preservation.
Methods. A validated model of BD in rabbits was developed and myocardial performance was studied after BD induction and 1 hour of subsequent global hypothermic ischemia using a validated rabbit model and an isolated work-performing heart preparation.
Results. Significant decreases in stroke work, left ventricular contractility, and left ventricular relaxation were observed 2 hours after BD. After global hypothermic ischemia, significant decreases in stroke work, left ventricular contractility, and left ventricular relaxation were observed in the BD group compared with controls. Cardiac output and coronary flow were also significantly decreased in BD hearts compared with controls. Creatine kinase release was increased by 32.5% in BD hearts compared with controls.
Conclusions. In a rabbit model, BD combined with global hypothermic ischemia causes a significant decrease in left ventricular function compared with global hypothermic ischemia. This dysfunction may be attributed to a significant decrease in coronary flows in BD hearts. 相似文献
Previous work has reported that the 5-hydroxytryptamine (5-HT)1A agonist, 8-hydroxy 2-(di-n-propylamino)tetralin (8-OH DPAT), reduces ethanol intake by rats. However, as 8-OH DPAT reduces 5-HT neurotransmission, these findings are inconsistent with the proposed inhibitory role of central 5-HT neurons on ethanol intake. We examined the effect of 8-OH DPAT on ethanol, water and food intake in rats maintained on a limited access schedule using a lower dose range (6–250 µg/kg) and by assessing concomitant changes in behaviour. Low doses of 8-OH DPAT enhanced ethanol intake even when food and water were offered as alternatives. Suppression in ethanol intake was observed at higher doses where elements of the 5-HT syndrome were apparent. Similar observations were made in both fluid and non-fluid deprived water drinking rats, suggesting the latter effect is non-selective. Therefore 8-OH DPAT may both increase or decrease ethanol consumption in the rat depending on the dose used. 相似文献
Molecular imaging by small-animal PET is an important noninvasive means to phenotype transgenic mouse models in vivo. When investigating pathologies of the left ventricular (LV) myocardium, the serial assessment of LV volumes is important. By this, the presence of LV dilation as a sign of developing heart failure can be detected. Whereas PET is usually used to derive biochemical and molecular information, functional parameters such as ventricular volumes are generally measured using echocardiography or MRI. In this study, a novel method to monitor LV dilation in mice with PET is presented and evaluated using cardiac MRI. METHODS: A semiautomatic 3-dimensional algorithm was used to delineate the LV myocardial wall on static PET images depicting myocardial glucose metabolism ((18)F-FDG PET) for 20 mice: 10 wild-type and 10 genetically modified littermates designed to develop a dilative cardiomyopathy phenotype (cardiomyocyte-specific knockout of survivin). The volume enclosed by the 3-dimensional midmyocardial contour was calculated as a measure for LV volume for each mouse. Data were compared with ventricular volumes measured by MRI in the same animals. RESULTS: LV volumes obtained by PET and MRI correlated well (R = 0.89) for hearts with small and large left ventricles. In accordance with the hypothesis, the LV volumes were increased significantly for transgenic mice examined at an older age compared with those examined at a younger age (MRI: 160.5 +/- 25.7 microL vs. 114.7 +/- 15.2 microL [P = 0.012]; PET: 129.3 +/- 15.3 microL vs. 73.8 +/- 15.0 microL [P < 0.001], all values shown as mean +/- SD; for MRI, mean of end-diastolic and end-systolic volumes are given), whereas they did not for their wild-type littermates (MRI: 106.2 +/- 12.3 microL vs. 94.7 +/- 14.6 microL [P = 0.214]; PET: 82.6 +/- 20.9 microL vs. 65.0 +/- 16.9 microL [P = 0.185]). CONCLUSION: Evaluation and quantitation of LV dilation in both control and cardiomyopathic mice can be reliably and serially performed using small-animal PET and (18)F-FDG, yielding useful functional information in addition to metabolic data. 相似文献
Vibrio vulnificus may cause severe soft tissue infections of the upper extremity. This pathogen usually gains access to soft tissues either by direct inoculation through a penetrating injury by an infected marine animal or by exposing abraded skin to contaminated water. We report five patients with Vibrio vulnificus hand infections following superficial hand injuries incurred within 24 hours after uneventful handling of fish. This clinical observation, together with the fact that the physiologic characteristics of human sweat simulate the natural environment of the Vibrio vulnificus, support the assumption that human skin may serve as a reservoir for Vibrios. The anamnesis in patients presenting with hand infection should essentially include an inquiry regarding recent, albeit uneventful, fish handling. 相似文献
PURPOSE: To simplify the clinical assessment of toric soft contact lens (TSCL) on-eye behavior by establishing a set of standard clinical evaluation techniques. The likely performance range expected among the TSCL wearing population was determined for a series of lens designs and acceptable performance standards indicated for each variable. METHODS: Four prism-ballast, two peri-ballast and one dynamic stabilization TSCL designs were each worn by groups of 20 subjects in a nondispensing study. After 20 min of lens wear, lenses were assessed, in right eyes only, for subjective comfort (100-point scale), lens mislocation (degrees deviation from vertical) and rotational recovery after deliberate 30 degrees mislocation (degrees/10 blinks). The percentage of lenses orienting within +/-10 degrees of target orientation (zero rotation) and the variability of orientation (standard deviation of mislocation) were also calculated for each lens group. RESULTS: Based on partitioning of the data distributions for each variable, performance was designated as excellent, acceptable or poor. Corresponding performance cut-offs were determined at > or =90, 89 to 80, and <80 for subjective comfort, < or =+/-6 degrees , +/-7 degrees to 10 degrees , and >+/-10 degrees for mislocation, >10 degrees /10 blinks, 10 degrees to 6 degrees /10 blinks, and <6 degrees /10 blinks for rotational recovery. For groups of wearers the appropriate cut-offs were > or =90%, 89 to 70%, and <70% of lenses orienting within +/-10 degrees of target orientation and <+/-6 degrees , +/-6 degrees to 10 degrees , and >+/-10 degrees for variability of orientation. CONCLUSION: Techniques suitable for the evaluation of TSCL clinical performance have been described and guidelines for the assessment of such lenses established. In the process, we have identified potential performance differences that may relate to variations in TSCL design. 相似文献