The hypothesis was tested that an initial lithium-tricyclic antidepressant (TCA) combination has a better antidepressant effect than standard TCA treatment in non-refractory depression at the beginning of an episode. Twenty bipolar melancholic type depressed inpatients under lithium-TCA treatment were compared with 20 patients with the same diagnosis and TCA-placebo treatment for 5 weeks under double-blind conditions. All patients were male. Initial lithium-TCA treatment reduced depressive symptoms significantly more than antidepressant treatment with TCA and placebo after 5 weeks, but not in weeks 1 or 2. It can be concluded that lithium augmentation of TCA treatment should be started even at the beginning of antidepressant TCA treatment to provide a better treatment response in those patients who will profit from long-term lithium prophylaxis, e.g. bipolar patients with melancholic type depression. 相似文献
Valproic acid (VPA) is a broad-spectrum antiepileptic drug and is usually well-tolerated. Rare serious complications may occur in some patients, including haemorrhagic pancreatitis, bone marrow suppression, VPA-induced hepatotoxicity and VPA-induced encephalopathy. The typical signs of VPA-induced encephalopathy are impaired consciousness, sometimes marked EEG background slowing, increased seizure frequency, with or without hyperammonemia. There is still no proof of causative effect of VPA in patients with encephalopathy, but only of an association with an assumed causal relation. We report 19 patients with VPA-associated encephalopathy in Germany from the years 1994 to 2003, none of whom had been published previously. 相似文献
This study of a series of 40 mildly head injured (concussed) patients suggests that different physiologic pathways underlying the tests done in a six-part resting EEG, and for the 11 evoked electrical potential shifts occurring in the cerebral terrain, are testable. Further work seems likely in order to ascertain which clinical signs and symptoms may be related to specific individual types of recorded electronic brain imaging (EBI) abnormality. Which of the 11 parameters studied, EEG, VER, AER, and SER, would be more or less likely to be abnormal in their individual patterns (as being deviant from normal controls) also remains to be defined. The relationship of these neurophysiologic abnormalities to certain postconcussive symptoms, i.e., headache, dizziness, blurred vision, etc., at this point in time remains to be evaluated more precisely. The authors suggest that further research is necessary in evaluating the clinical use of somatosensory evoked responses as an additional parameter in electronic brain imaging (EBI) technology. 相似文献
BACKGROUND: Oxytocin is known to reduce anxiety and stress in social interactions as well as to modulate approach behavior. Recent studies suggest that the amygdala might be the primary neuronal basis for these effects. METHODS: In a functional magnetic resonance imaging study using a double-blind, placebo-controlled within-subject design, we measured neural responses to fearful, angry, and happy facial expressions after intranasal application of 24 IU oxytocin compared with placebo. RESULTS: Oxytocin reduced right-sided amygdala responses to all three face categories even when the emotional content of the presented face was not evaluated explicitly. Exploratory whole brain analysis revealed modulatory effects in prefrontal and temporal areas as well as in the brainstem. CONCLUSIONS: Results suggest a modulatory role of oxytocin on amygdala responses to facial expressions irrespective of their valence. Reduction of amygdala activity to positive and negative stimuli might reflect reduced uncertainty about the predictive value of a social stimulus and thereby facilitates social approach behavior. 相似文献
Background: Measuring the work of breathing of patients undergoing spontaneous assisted ventilation can be useful to monitor and titrate ventilatory support. The aim of this study was to obtain measurements of the pressure generated by the respiratory muscles (PMUSC) and the derived pressure-time product (PTP; a good indicator of the metabolic work of breathing), performing the rapid interrupter technique with a commercial ventilator.
Methods: A Draeger Evita 4 ventilator (Draeger Medical, Lubeck, Germany) was controlled by a personal computer to rapidly interrupt the airway flow at different times and volumes of the respiratory cycle during pressure-support ventilation. From the airway pressure tracing after the occlusion, the authors estimated the alveolar pressure and PMUSC; the integration of PMUSC values over the inspiratory time yields the measurement of PTP. Esophageal pressure measurements were used as a reference. After a bench study of the valves' performance, the authors performed 11 measurement sequences in eight patients.
Results: The closure times for the inspiratory and expiratory valves were 74 +/- 10 and 61 +/- 13 ms, respectively. The interrupter technique provided a reliable estimate of PMUSC (PMUSC, occl = 1.00 [middle dot] PMUSC, pes + 0.19; r = 0.88; 95% confidence interval for agreement, +5.49/-5.32 cm H2O). PTPoccl tightly correlated with PTPpes (PTPoccl = 0.95 [middle dot] PTPpes + 0.13; r = 0.96; 95% confidence interval, 1.94/-1.61 cm H2O [middle dot] s). 相似文献
A numerical simulation tool was developed to calculate the echo amplitudes of J-coupled resonances within a series of radiofrequency (RF) refocused echoes. The signal modulation due to J-coupling in rapid acquisition with relaxation enhancement (RARE) is suppressed only when the inverse of the pulse interval (tau) is large compared to both the chemical shift (CS) difference (Deltadelta) of the coupled spins and the coupling constant. In contrast, the echo amplitudes in ultrafast low-flip-angle RARE (U-FLARE) oscillate around a quasi-steady-state value that is greater than zero (neglecting relaxation and diffusion) even when Deltadelta > 1/tau. The flip-angle distribution over the measured slice caused by the use of Gaussian-shape slice-selective refocusing pulses further reduces the echo oscillations. When the pulse interval falls short of the fast pulse rate regime, spectroscopic U-FLARE provides an improved spatial impulse response in the phase-encoding (PE) direction compared to spectroscopic RARE. 相似文献
(18)F-FDG PET is the most accurate noninvasive modality for staging mediastinal lymph nodes in lung cancer. Besides using visual image interpretation, some institutions use standardized uptake value (SUV) measurements in lymph nodes. Mostly, an SUV of 2.5 is used as the cutoff, but this choice was never deduced from respective studies. Receiver operating characteristic (ROC) analyses demonstrated that SUV thresholds of more than 4 resulted in the highest accuracy. But these high cutoffs imply high false-negative rates (FNRs). The aim of our evaluation was to determine an optimal SUV threshold and to compare its diagnostic performance with the results of visual interpretation. METHODS: This retrospective study included 95 patients with suspected lung cancer who underwent mediastinoscopy/mediastinal lymphadenectomy after (18)F-FDG PET (90-150 min after 250 MBq of (18)F-FDG). Maximum SUV was measured in 371 lymph node regions biopsied afterward and visually interpreted using a 6-level score (- - - through + + +). Diagnostic performance was assessed by ROC analysis. FNR and false-positive rate (FPR), the sum of both error rates (FNR + FPR), and diagnostic accuracy were plotted against a hypothetical SUV threshold to determine the optimum SUV threshold. RESULTS: SUVs in metastatic lymph nodes were higher (mean +/- SD, 7.1 +/- 4.5; range, 1.4-26.9; n = 70) than in tumor-free lymph node stations (2.4 +/- 1.7; range, 0.6-14.9; n = 301; P < 0.01). Inflammatory lymph nodes exhibited slightly increased SUVs (2.7 +/- 2.0; range, 0.8-14.9; n = 146). The plot of error rates featured a minimum of the sum FNR + FPR for an SUV of 2.5. With increasing SUV threshold, the FPR decreased most prominently up to that value whereas a continuous rise of FNR was noticed. Highest diagnostic accuracy was achieved with an SUV of 4.5. The areas under the ROC curves demonstrated that visual interpretation tends to be more accurate than SUV quantification (visual, 0.930 +/- 0.022; SUV, 0.899 +/- 0.025; P = 0.241). Using an SUV of 2.5 as the threshold, the resulting sensitivity, specificity, and negative predictive value were 89%, 84%, and 96%, respectively. CONCLUSION: For mediastinal staging, the choice of an SUV of 2.5 as the threshold is justified because FNR + FPR is minimized. The resulting high negative predictive value of 96% allows the omission of mediastinoscopy in patients with negative mediastinal findings on (18)F-FDG PET images. For the experienced observer, visual analysis should be relied on primarily, with calculation of the SUV used, at most, as a secondary aid. For the less experienced observer, the SUV may be of greater value. 相似文献