排序方式: 共有66条查询结果,搜索用时 0 毫秒
61.
62.
63.
Privatdozent Dr. G. Schlomka 《Journal of molecular medicine (Berlin, Germany)》1933,12(43):1677-1683
Ohne Zusammenfassung 相似文献
64.
Hans Baumm A. Schüller Ostertag Karl Nissen Panse H. Pfister Giese Esser Breitenecker Schlomka Haim L. Wachholz Walcher Wohlgemuth Tanturri Hoenig Schönberg H. Schmutte Bresowsky K. Landé Spiecker Zavka Meixner Dietrich Blos Estler Winter Vidlička G. Strassmann Pfleiderer Schrader 《International journal of legal medicine》1935,24(1):11-23
65.
Feuerlein S Roessl E Proksa R Martens G Klass O Jeltsch M Rasche V Brambs HJ Hoffmann MH Schlomka JP 《Radiology》2008,249(3):1010-1016
The purpose of this study was to investigate whether spectral computed tomography (CT) has the potential to improve luminal depiction by differentiating among intravascular gadolinium-based contrast agent, calcified plaque, and stent material by using the characteristic k edge of gadolinium. A preclinical spectral CT scanner with a photon-counting detector and six energy threshold levels was used to scan a phantom vessel. A partially occluded stent was simulated by using a calcified plaque isoattenuated to a surrounding gadolinium chelate solution. The reconstructed images showed an effective isolation of the gadolinium with subsequent clear depiction of the perfused vessel lumen. The calcified plaque and the stent material are suppressed. 相似文献
66.
Coherent scatter computed tomography (CSCT) is a reconstructive x-ray imaging technique that yields the spatially resolved coherent-scatter form factor of the investigated object. Reconstruction from coherently scattered x-rays is commonly done using algebraic reconstruction techniques (ART). In this paper, we propose an alternative approach based on filtered back-projection. For the first time, a three-dimensional (3D) filtered back-projection technique using curved 3D back-projection lines is applied to two-dimensional coherent scatter projection data. The proposed algorithm is tested with simulated projection data as well as with projection data acquired with a demonstrator setup similar to a multi-line CT scanner geometry. While yielding comparable image quality as ART reconstruction, the modified 3D filtered back-projection algorithm is about two orders of magnitude faster. In contrast to iterative reconstruction schemes, it has the advantage that subfield-of-view reconstruction becomes feasible. This allows a selective reconstruction of the coherent-scatter form factor for a region of interest. The proposed modified 3D filtered back-projection algorithm is a powerful reconstruction technique to be implemented in a CSCT scanning system. This method gives coherent scatter CT the potential of becoming a competitive modality for medical imaging or nondestructive testing. 相似文献