全文获取类型
收费全文 | 42篇 |
免费 | 0篇 |
专业分类
儿科学 | 2篇 |
基础医学 | 1篇 |
内科学 | 10篇 |
皮肤病学 | 1篇 |
神经病学 | 3篇 |
特种医学 | 14篇 |
外科学 | 5篇 |
预防医学 | 2篇 |
药学 | 2篇 |
肿瘤学 | 2篇 |
出版年
2018年 | 1篇 |
2016年 | 1篇 |
2014年 | 1篇 |
2013年 | 1篇 |
2011年 | 2篇 |
2010年 | 3篇 |
2008年 | 2篇 |
2007年 | 2篇 |
2006年 | 1篇 |
2005年 | 2篇 |
2002年 | 2篇 |
2001年 | 3篇 |
2000年 | 4篇 |
1999年 | 4篇 |
1994年 | 1篇 |
1992年 | 1篇 |
1991年 | 1篇 |
1990年 | 3篇 |
1989年 | 1篇 |
1988年 | 1篇 |
1987年 | 1篇 |
1986年 | 1篇 |
1985年 | 1篇 |
1983年 | 1篇 |
1981年 | 1篇 |
排序方式: 共有42条查询结果,搜索用时 15 毫秒
21.
F Lumachi G Ferretti M Povolato M C Marzola P Zucchetta O Geatti A A Brandes F Bui 《European journal of nuclear medicine》2001,28(12):1776-1780
The aim of this study was to evaluate the usefulness of technetium-99m sestamibi scintimammography (SSM) and combined use of SSM and X-ray mammography (MG) in premenopausal patients with small (< or =2 cm) suspicious breast lesions. Eighty-seven premenopausal women (median age 47 years, range 32-52) with breast lesions ranging from 4 to 20 mm in greatest diameter (median 12 mm) and detected by MG, underwent SSM prior to open breast biopsy. A planar camera and single-photon emission tomography (SPET) technique were used in 23 (26.4%) and 64 (73.6%) patients, respectively. At histological examination, 72 (82.8%) breast cancers (pT1a=3, pT1b=27, pT1c=42) and 15 (17.2%) benign masses were found. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of MG and SSM were 80.6% vs 80.6%, 60.0% vs 93.3% (P<0.05), 90.6% vs 98.3%, 39.1% vs 50.0% and 77.0% vs 82.8%, respectively. MG + SSM together had a sensitivity of 94.4% (P<0.05 vs SSM alone) and an accuracy of 82.8% for the detection of breast cancer. Tumours undetected by both MG and SSM were significantly (P<0.05) smaller than those correctly diagnosed. Patients with false-negative MG were younger (P<0.05) than those with tumours correctly detected, while SSM sensitivity was independent (P=NS) of age. In conclusion, in premenopausal patients with small breast lesions, the sensitivity of SSM and MG is similar (P=NS), whereas the specificity of SSM is significantly higher (P<0.05) than that of MG. Furthermore, the combination of MG and SSM offers significantly improved sensitivity and accuracy in comparison with the individual techniques, suggesting a complementary role of SSM in the detection of breast cancer in younger patients. 相似文献
22.
Usefulness of 99m-Tc-sestamibi scintimammography in suspected breast cancer and in axillary lymph node metastases detection. 总被引:2,自引:0,他引:2
F Lumachi G Ferretti M Povolato M C Marzola P Zucchetta O Geatti F Bui A A Brandes 《European journal of surgical oncology》2001,27(3):256-259
AIMS: To evaluate the usefulness of 99m-Tc-sestamibi scintimammography (SSM) in the detection of T1-2, N0-1, M0 breast cancer (BC) and axillary node (AN) metastases. PATIENTS AND METHODS: A series of 239 women (median age 55 years) who had already been selected for breast biopsy underwent both mammography (MG) and SSM before surgery. The final diagnosis confirmed in 207 (86.6%) patients, and benign breast lesions in 32 (13.4%). RESULTS: Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MG and SSM in BC detection were 88.9% vs 87.9%, 62.5% vs 93.8% (P<0.01), 93.9% vs 98.9%, 46.5% vs 54.5%, and 85.4% vs 88.7%, respectively. Age did not affect (P=NS) SSM sensitivity, and in premenopausal patients (n=80 (33.5%)) its specificity was 100%. Overall sensitivity and specificity of SSM for assessing AN involvement were 82.3% and 94.1%, respectively. In patients with <3 AN metastases (n=33 (53.2%)) SSM sensitivity was 69.7%, and only one out of six patients with a single AN metastasis had a positive scan. CONCLUSIONS: In patients with suspicious MG undergoing biopsy, SSM should be considered before surgery because of its high specificity, especially in younger patients. At present, its usefulness in detection of AN metastases is still modest and does not allow a correct pre-operative staging of patients with BC. Copyright Harcourt Publishers Limited. 相似文献
23.
Brendan A. Rich Tom Holroyd Frederick W. Carver Laura M. Onelio Jennifer K. Mendoza Brian R. Cornwell Nathan A. Fox Daniel S. Pine Richard Coppola Ellen Leibenluft 《Depression and anxiety》2010,27(3):276-286
Background: Irritability is prevalent and impairing in pediatric bipolar disorder (BD) but has been minimally studied using neuroimaging techniques. We used magnetoencephalography (MEG) to study theta band oscillations in the anterior cingulate cortex (ACC) during frustration in BD youth. ACC theta power is associated with attention to emotional stimuli, and the ACC may mediate responses to frustrating stimuli. Methods: We used the affective Posner task, an attention paradigm that uses rigged feedback to induce frustration, to compare 20 medicated BD youth (14.9±2.0 years; 45% male) and 20 healthy controls (14.7±1.7 years; 45% male). MEG measured neuronal activity after negative and positive feedback; we also compared groups on reaction time, response accuracy, and self‐reported affect. Patients met strict DSM‐IV BD criteria and were euthymic. Controls had no psychiatric history. Results: BD youth reported more negative affective responses than controls. After negative feedback, BD subjects, relative to controls, displayed greater theta power in the right ACC and bilateral parietal lobe. After positive feedback, BD subjects displayed lower theta power in the left ACC than did controls. Correlations between MEG, behavior, and affect were nonsignificant. Conclusion: In this first MEG study of BD youth, BD youth displayed patterns of theta oscillations in the ACC and parietal lobe in response to frustration‐inducing negative feedback that differed from healthy controls. These data suggest that BD youth may display heightened processing of negative feedback and exaggerated self‐monitoring after frustrating emotional stimuli. Future studies are needed with unmedicated bipolar youth, and comparison ADHD and anxiety groups. Depression and Anxiety, 2010. © 2009 Wiley‐Liss, Inc. 相似文献
24.
25.
26.
27.
In order to support interested colleagues with the concepts of Continuous Quality Improvement (CQI) and Clinical Standards for Nephrology Practice, a package of education support has been set up. We enhance the use of procedures, protocols, working plans, guidelines and nursing care plans as instruments of organisational integration. For the nursing care of renal patients in HD and PD we believe that all the procedures and protocols (P&P) above could have an important impact in the renal nursing practice. We propose that group members run a programme which is presented and implemented as a modular package including, theoretical knowledge, setting up working groups involved in literature revision, evaluation of defined P&P after a period of implementation, final implementation & periodic evaluation. 相似文献
28.
Franco Lumachi Guido Ferretti Michele Povolato Maria Marzola Pietro Zucchetta Onelio Geatti Alba A. Brandes Franco Bui 《European journal of nuclear medicine and molecular imaging》2001,28(12):1776-1780
The aim of this study was to evaluate the usefulness of technetium-99m sestamibi scintimammography (SSM) and combined use of SSM and X-ray mammography (MG) in premenopausal patients with small (В cm) suspicious breast lesions. Eighty-seven premenopausal women (median age 47 years, range 32-52) with breast lesions ranging from 4 to 20 mm in greatest diameter (median 12 mm) and detected by MG, underwent SSM prior to open breast biopsy. A planar camera and single-photon emission tomography (SPET) technique were used in 23 (26.4%) and 64 (73.6%) patients, respectively. At histological examination, 72 (82.8%) breast cancers (pT1a=3, pT1b=27, pT1c=42) and 15 (17.2%) benign masses were found. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of MG and SSM were 80.6% vs 80.6%, 60.0% vs 93.3% (P<0.05), 90.6% vs 98.3%, 39.1% vs 50.0% and 77.0% vs 82.8%, respectively. MG + SSM together had a sensitivity of 94.4% (P<0.05 vs SSM alone) and an accuracy of 82.8% for the detection of breast cancer. Tumours undetected by both MG and SSM were significantly (P<0.05) smaller than those correctly diagnosed. Patients with false-negative MG were younger (P<0.05) than those with tumours correctly detected, while SSM sensitivity was independent (P=NS) of age. In conclusion, in premenopausal patients with small breast lesions, the sensitivity of SSM and MG is similar (P=NS), whereas the specificity of SSM is significantly higher (P<0.05) than that of MG. Furthermore, the combination of MG and SSM offers significantly improved sensitivity and accuracy in comparison with the individual techniques, suggesting a complementary role of SSM in the detection of breast cancer in younger patients. 相似文献
29.
Federico Caobelli Pierpaolo Alongi Laura Evangelista Maria Picchio Giorgio Saladini Marco Rensi Onelio Geatti Angelo Castello Iashar Laghai Cristina E. Popescu Carlotta Dolci Cinzia Crivellaro Silvia Seghezzi Margarita Kirienko Vincenzo De Biasi Fabrizio Cocciolillo Natale Quartuccio Young AIMN Working Group 《European journal of nuclear medicine and molecular imaging》2016,43(3):404-413
Purpose
Ovarian cancer is the eighth most common malignancy among women and has a high mortality rate. Prognostic factors able to drive an effective therapy are essential. 18F-Fluoro-2-deoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) has been investigated in patients with epithelial ovarian cancer and showed promise in diagnosing, staging, detecting recurrent lesions and monitoring treatment response. Conversely, its prognostic role remains unclear. We aimed at assessing the prognostic value of 18F-FDG PET/CT performed in the restaging process in a multicentre study.Methods
We evaluated 168 patients affected by ovarian carcinoma, who underwent a restaging 18F-FDG PET/CT. The presence of local recurrences, lymph node involvement and distant metastasis was recorded as well as lesion dimensions, maximum and mean standardized uptake values (SUVmax and SUVmean, respectively). Progression-free survival (PFS) and overall survival (OS) at 3 and 4 years were computed by using Kaplan-Meier curves. Increased odds ratio was assessed using Cox regression analysis testing all lesion parameters measured by PET/CT.Results
PFS was significantly longer in patients with a negative than a positive restaging PET/CT study (3- and 4-year PFS 64 and 53 % vs 23 and 12 %, respectively; p?<?0.001). Similarly, a negative study was associated with a significantly higher OS rate after 4 years of follow-up (67 vs 25 % in negative and positive groups, respectively; p?<?0.001). Lymph node or distant involvement were also independently associated with an increased risk of disease progression [hazard ratio (HR) 1.6 and 2.2, respectively; p?=?0.003]. Moreover, PET/CT showed an incremental prognostic value compared to the International Federation of Gynecology and Obstetrics (FIGO) staging system. In the analysis of patient subsets, individuals with the same FIGO stage I–II but with negative PET had a significantly better 4-year OS than patients with low FIGO stage but positive PET. This implies that patients with the same FIGO stage can be further prognostically stratified using PET (p?=?0.01). At receiver-operating characteristic (ROC) analysis, no thresholds for semiquantitative parameters were predictive of a worse outcome.Conclusion
18F-FDG PET/CT has an important prognostic value in assessing the risk of disease progression and mortality rate. An efficacious therapy planning might therefore effectively rely on 18F-FDG PET/CT findings. Semiquantitative data were not proven to be an effective tool to predict disease progression.30.
A patient presented with recurrent pheochromocytoma 10 years following the apparently successful surgical cure of a right adrenal pheochromocytoma. Conventional medical imaging techniques, (chest radiograph, abdominal ultrasound, and abdominal CT) suggested local recurrence for which surgery was planned. I-131 MIBG scintigraphy revealed disseminated metastatic disease that rendered attempts at surgical cure futile. The patient was treated with three therapeutic doses of I-131 MIBG with good symptomatic palliation and improvement of some biochemical parameters. 相似文献