A 49 year old man presented with near-fatal, fulminant, haemorrhagic cardiac tamponade. He responded well to emergency pericardiocentesis and subsequent investigation revealed the cause to be an unknown squamous carcinoma of the bronchus with pericardial involvement. He died 13 weeks later. Such a dramatic presentation of this type of tumour in a male patient has not been previously described. 相似文献
Naloxone, an opioid peptide antagonist, has been reported to facilitate voiding in neurologic bladder disorders, but its effects on the neural micturition reflex arc are poorly understood. We studied the effect of naloxone in 34 male adult cats, spinalized at C5-C6 level 7 to 119 days previously. Each cat served as its own control. The following tests were performed: Urethral pressure profiles, cystosphincterograms with the urethro-vesical junction opened and closed and mechanograms of the detrusor, and the circular and longitudinal urethral muscles. The study included (1) the effects of anesthesia of the bladder and pelvic nerve, as well as that of the urethral and pudendal nerves; (2) the action of naloxone; and (3) the action of oxymorphone. Our results demonstrated that naloxone (1) increased somatic (osteotendinous and nociceptive) reflexes and aggravated spasticity; (2) increased vegetative micturitional and sexual reflexes, in particular the urethra-urethral contraction reflex, aggravating the spasmodic contractions of the external sphincter; and (3) increased the frequency and intensity of the mass reflex. In consequence, we suggest that naloxone is contraindicated in cases of spinal cord lesions with detrusor-sphincter dyssynergia syndrome. 相似文献
Vitamin E is comprised of four tocopherols and four tocotrienols, and functions as a lipophilic chain-breaking antioxidant that prevents lipid peroxidation. Although it is well recognized that cigarette smoke is source of oxidative stress, relatively little is known regarding how oxidative stress alters vitamin E utilization in humans. Therefore, this review will highlight the recent knowledge regarding how cigarette smoking alters vitamin E (as alpha- and gamma-tocopherols) utilization in humans. Specifically, we will discuss the mechanisms by which cigarette smoking increases the turnover of plasma vitamin E, decreases the P450-mediated metabolism of vitamin E, and increases the nitration of gamma-tocopherol to result in the formation of 5-nitro-gamma-tocopherol. In addition, the interrelationship between oxidative stress and vitamin C will also be emphasized as it relates to vitamin E utilization. 相似文献
OBJECTIVE: Biventricular pacing has demonstrated improvement in cardiac function in treating congestive heart failure (CHF). Two different operative strategies (coronary sinus vs. epicardial stimulation) for left ventricular (LV) pacing were compared. METHODS: Since April 1999, a total of 86 patients (pts, age: 63+/-10 years) with depressed systolic LV function (mean ejection fraction 24+/-9%), left bundle-branch-block (mean QRS 182+/-22 ms) and congestive heart failure NYHA III or higher were enrolled. For biventricular stimulation coronary sinus (CS) leads were placed in 79 pts. Nine of these devices were converted to surgical epicardial LV-leads, because of CS-lead failure. In 7 patients epicardial LV-leads were initially implanted surgically, accounting for a total of 16 pts with surgical placed epicardial steroid-eluting LV-leads. For these, a limited left-lateral thoracotomy (7+/-4 cm) was used. Thirty-three (38%) pts had an indication for a defibrillator. The mean follow-up time was 16.4+/-15.4 months (0.1-45 months), representing 107.1 patient-years. RESULTS: In the biventricular pacing mode, QRS duration decreased to 143+/-16 ms (P<0.001). Threshold capture of the CS-leads increased significantly compared to surgically placed epicardial leads (18 month control: 2.2+/-1.4V/0.5 ms vs. 0.7+/-0.3V/0.5 ms), which had no increase in threshold (P<0.001). At the 18 month follow-up 7 CS-leads had a threshold of >4V/0.5 ms vs. epicardial leads which were under 1.1V/0.5 ms, except for one (1.8V/0.5 ms). After CS-lead implantation 25 LV-lead related complications occurred, (failed implantation, CS-dissection, loss of pacing capture, diaphragm stimulation or lead dislodgment), vs. one dislodgement after surgical epicardial lead placement (P<0.05). Correct lead positioning (obtuse marginal branch area) was achieved in all surgical epicardial placements but only in 70% with CS-leads (P<0.03). In the follow up period, 9 pts died (4 cardiac related). Heart transplantation was necessary in 4 pts due to deterioration of the cardiomyopathy. CONCLUSIONS: Surgical epicardial lead placement revealed excellent long-term results and a lower LV-related complication rate compared to CS-leads. Although, the approach via limited thoracotomy for biventricular pacing is associated with 'more surgery', it is a safe and reliable technique and should be considered as an equal alternative. 相似文献
Background: A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced.
Methods: Ten volunteers breathed 500 ppm carbon monoxide until their carboxyhemoglobin levels reached 15%, and 10 different volunteers received intravenous sodium nitrite, 300 mg, to induce methemoglobin. All were instrumented with arterial cannulas and six Masimo Rad-57 (Masimo Inc., Irvine, CA) pulse oximeter sensors. Arterial blood was analyzed by three laboratory CO-oximeters, and the resulting carboxyhemoglobin and methemoglobin measurements were compared with the corresponding pulse oximeter readings.
Results: The Rad-57 measured carboxyhemoglobin with an uncertainty of +/-2% within the range of 0-15%, and it measured methemoglobin with an uncertainty of 0.5% within the range of 0-12%. 相似文献