全文获取类型
收费全文 | 403篇 |
免费 | 9篇 |
专业分类
儿科学 | 1篇 |
基础医学 | 5篇 |
临床医学 | 69篇 |
内科学 | 145篇 |
皮肤病学 | 2篇 |
神经病学 | 1篇 |
特种医学 | 158篇 |
外科学 | 13篇 |
综合类 | 2篇 |
预防医学 | 6篇 |
药学 | 1篇 |
肿瘤学 | 9篇 |
出版年
2022年 | 3篇 |
2021年 | 5篇 |
2020年 | 1篇 |
2018年 | 8篇 |
2017年 | 4篇 |
2016年 | 6篇 |
2015年 | 9篇 |
2014年 | 18篇 |
2013年 | 22篇 |
2012年 | 28篇 |
2011年 | 27篇 |
2010年 | 17篇 |
2009年 | 21篇 |
2008年 | 28篇 |
2007年 | 29篇 |
2006年 | 36篇 |
2005年 | 40篇 |
2004年 | 21篇 |
2003年 | 20篇 |
2002年 | 13篇 |
2001年 | 9篇 |
2000年 | 15篇 |
1999年 | 6篇 |
1998年 | 2篇 |
1997年 | 5篇 |
1995年 | 8篇 |
1994年 | 3篇 |
1993年 | 4篇 |
1992年 | 1篇 |
1991年 | 1篇 |
1990年 | 1篇 |
1983年 | 1篇 |
排序方式: 共有412条查询结果,搜索用时 15 毫秒
191.
T.E. Brinkley F.-C. Hsu J.J. Carr W.G. Hundley D.A. Bluemke J.F. Polak J. Ding 《Nutrition, metabolism, and cardiovascular diseases : NMCD》2011,21(5):332-338
Background and aims
Arterial stiffness is a prominent feature of vascular aging and a risk factor for cardiovascular disease (CVD). Fat around the heart and blood vessels (i.e. pericardial fat, Pfat) may contribute to arterial stiffness via a local paracrine effect of adipose tissue on the surrounding vasculature. Thus, we determined the association between Pfat and carotid stiffness in 5770 participants (mean age 62 years, 53% female, 25% African American, 24% Hispanic, and 13% Chinese) from the Multi-Ethnic Study of Atherosclerosis.Methods and results
Pfat was measured by computed tomography, and ultrasonography of the common carotid artery was used to calculate the distensibility coefficient (DC) and Young's modulus (YM). Lower DC and higher YM values indicate stiffer arteries. Pfat quartile was highly associated with demographic, behavioral, anthropometric, hemodynamic, metabolic, and disease variables in both men and women. After adjusting for height, clinical site, CVD risk factors, and medications, a 1 standard deviation (41.91 cm3) increment in Pfat was associated with a 0.00007 ± 0.00002 1/mmHg lower DC (p = 0.0002) in men and a 48.1 ± 15.1 mmHg/mm higher YM in women (p = 0.002). Additional adjustment for C-reactive protein, coronary artery calcification, and carotid intima-media thickness had only modest effects. More importantly, adjusting for body mass index and waist circumference did not significantly change the overall results.Conclusion
Higher Pfat is associated with higher carotid stiffness, independent of traditional CVD risk factors and obesity. 相似文献192.
193.
Neville Gai Evrim B. Turkbey Saman Nazarian Rob J. van der Geest Chia‐Ying Liu João A. C. Lima David A. Bluemke 《Magnetic resonance in medicine》2011,65(5):1407-1415
Quantitative T1 mapping of delayed gadolinium‐enhanced cardiac magnetic resonance imaging has shown promise in identifying diffuse myocardial fibrosis. Despite careful control of magnetic resonance imaging parameters, comparison of T1 times between different patients may be problematic because of patient specific factors such as gadolinium dose, differing glomerular filtration rates, and patient specific delay times. In this work, a model driven approach to account for variations between patients to allow for comparison of T1 data is provided. Kinetic model parameter values were derived from healthy volunteer time‐contrast curves. Correction values for the factors described above were used to normalize T1 values to a matched state. Examples of pre‐ and postcorrected values for a pool of normal subjects and in a patient cohort of type 1 diabetic patients shows tighter clustering and improved discrimination of disease state. Magn Reson Med, 2011. © 2010 Wiley‐Liss, Inc. 相似文献
194.
Cancer yield of mammography, MR, and US in high-risk women: prospective multi-institution breast cancer screening study 总被引:2,自引:0,他引:2
Lehman CD Isaacs C Schnall MD Pisano ED Ascher SM Weatherall PT Bluemke DA Bowen DJ Marcom PK Armstrong DK Domchek SM Tomlinson G Skates SJ Gatsonis C 《Radiology》2007,244(2):381-388
PURPOSE: To prospectively determine cancer yield, callback and biopsy rates, and positive predictive value (PPV) of mammography, magnetic resonance (MR) imaging, and ultrasonography (US) in women at high risk for breast cancer. MATERIALS AND METHODS: The study was approved by the institutional review board and was HIPAA compliant, and informed consent was obtained. We conducted a prospective pilot study of screening mammography, MR, and US in asymptomatic women 25 years of age or older who were genetically at high risk, defined as BRCA1/BRCA2 carriers or with at least a 20% probability of carrying a BRCA1/BRCA2 mutation. All imaging modalities were performed within 90 days of each other. Data were analyzed by using exact confidence intervals (CIs) and the McNemar test. RESULTS: A total of 195 women were enrolled in this study over a 6-month period, and 171 completed all study examinations (mammography, US, and MR). Average age of the 171 participants was 46 years +/- 10.2 (standard deviation). Sixteen biopsies were performed and six cancers were detected, for an overall 3.5% cancer yield. MR enabled detection of all six cancers; mammography, two; and US, one. The diagnostic yields for each test were 3.5% for MR, 0.6% for US, and 1.2% for mammography. MR, US, and mammography findings prompted biopsy in 8.2%, 2.3%, and 2.3% of patients, respectively. None of the pairwise comparisons were statistically significant. The PPV of biopsies performed as a result of MR was 43%. CONCLUSION: Screening MR imaging had a higher biopsy rate but helped detect more cancers than either mammography or US. US had the highest false-negative rate compared with mammography and MR, enabling detection of only one in six cancers in high-risk women. 相似文献
195.
Foo TK Slavin GS Bluemke DA Montequin M Hood MN Ho VB 《Journal of magnetic resonance imaging : JMRI》2007,26(4):927-933
PURPOSE: To develop a method for fat suppression in myocardial delayed enhancement (MDE) studies that achieves effective signal intensity reduction in fat but does not perturb myocardial signal suppression. MATERIALS AND METHODS: A new approach to fat suppression that uses a spectrally-selective inversion-recovery (SPEC-IR) tip-up radio frequency (RF) pulse following the conventional nonselective IR RF pulse together with a second SPEC-IR RF pulse is proposed. The tip-up pulse restores the fat longitudinal magnetization after the nonselective IR pulse and allows the fat magnetization to recover more fully toward its equilibrium value, providing for better fat suppression by the second SPEC-IR RF pulse. This new approach was validated in phantom studies and in five patients. RESULTS: Effective fat suppression was achieved using the proposed technique with minimal impact on normal myocardial signal suppression. Mean fat suppression achieved using this approach was 67% +/- 8%, as measured in the chest wall immediately opposite the heart. CONCLUSION: The results indicate this modular-type approach optimizes fat suppression in myocardial delayed enhancement studies but does not perturb the basic IR pulse sequence or change basic acquisition parameters. 相似文献
196.
197.
198.
Schmidt A Azevedo CF Cheng A Gupta SN Bluemke DA Foo TK Gerstenblith G Weiss RG Marbán E Tomaselli GF Lima JA Wu KC 《Circulation》2007,115(15):2006-2014
199.
Indik JH Dallas WJ Gear K Tandri H Bluemke DA Moukabary T Marcus FI 《The international journal of cardiovascular imaging》2012,28(5):995-1001
Imaging of the right ventricle (RV) for the diagnosis of arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is commonly performed by echocardiography or magnetic resonance imaging (MRI). Angiography is an alternative modality, particularly when MRI cannot be performed. We hypothesized that RV volume and ejection fraction computed by angiography would correlate with these quantities as computed by MRI. RV volumes and ejection fraction were computed for subjects enrolled in the North American ARVC/D Registry, with both RV angiography and MRI studies. Angiography was performed in the 30° right anterior oblique (RAO) and 60° left anterior oblique (LAO) views. Angiographic volumes were computed by RAO view and two-view (RAO and LAO) formulae. 17 subjects were analyzed (11 men and 6 women), with 15 subjects classified as affected, and two as unaffected by modified Task Force criteria. The correlation coefficient of MRI to the two-view angiographic analysis was 0.72 (P = 0.003) for end-diastolic volume and 0.68 (P = 0.005) for ejection fraction. Angiographically derived volumes were larger than MRI derived volume (P = 0.009) and with the slope in a linear relationship equal to 0.8 for end diastolic volume, and 0.9 for RV ejection fraction (P < 0.001), computed by the two view formula. End-diastolic volumes and ejection fractions of the RV obtained by dual view angiography correlate with these quantities by MRI. RV end-diastolic volumes are larger by RV angiography in comparison with MRI. 相似文献