Y zeolites with different sodium contents and a sodium mordenite were evaluated as support for bis(cyclopentadienyl)zirconium dichloride as catalyst for ethylene polymerization. The results showed that, although the activities of the supported catalysts were lower than that of the homogeneous system, the average molecular weight of the polyethylene produced from the former was in general much higher than that of the polymer produced in solution. Contrary to the expected trend if the specific area was the dominant factor for catalyst activity, the best catalyst was the one supported on NaM zeolite. Thus, our results indicate that the concentration of framework aluminium atoms is the dominant factor, but that the contribution of the external surface is also important. 相似文献
The role of glutamate in conditioned taste aversion was investigated. Both, in the amygdala (AMYG) and in the lateral hypothalamus (LH) extracellular levels of glutamate were assessed by microdialysis and capillary electrophoresis with laser induced fluorescence detection. Rats were conditioned by pairing a novel flavor (strawberry flavor) with an intraperitoneal injection of lithium chloride. When the conditioned stimulus (strawberry flavored solution) was injected into the mouth of conditioned rats, there was an increase of glutamate release in the AMYG, and a decrease in glutamate release in the LH. These results predicted that glutamate release in the AMYG and the LH was involved in CTA. This possibility was tested by MK-801 (glutamate antagonist) and glutamate microinjections. MK-801 injections in AMYG attenuated the rejection of the novel flavor, and in the LH did not cause any effect on CTA. Glutamate microinjections in the AMYG caused CTA. These results suggest that glutamatergic activity in the AMYG might be a relevant neurochemical correlate and cause of conditioned taste aversion. 相似文献
OBJECTIVES: To determine the accuracy of self-reported comorbidities compared with medical record review and the clinical and sociodemographic characteristics associated with accuracy of self-reported comorbidities. STUDY DESIGN: We conducted a prospective study of 458 newly diagnosed head and neck cancer patients using self-administered questionnaire and medical chart review data. Overall and itemwise consistency between self-report and chart review was evaluated. Social, clinical, and demographic characteristics of consistent versus inconsistent responders were analyzed. RESULTS: Seventy-four percent of patients had at least one comorbidity. There was good overall consistency between self-report and chart review (kappa = 0.50). Compared with consistent responders, inconsistent responders were found to be older (P < 0.05), have lower sleep (P < 0.05) and physical activity scores (P < 0.05), be more depressed (P < 0.05), and have more severe comorbidities (P < 0.05). CONCLUSIONS AND SIGNIFICANCE: Self-report may be considered as an alternative to chart review for comorbidity assessment in head and neck cancer patients. Younger patients, those with good general health, fewer depressive symptoms, and mild comorbidities, are more likely to give responses consistent with chart review. 相似文献
Background: Nonsteroidal anti-inflammatory drugs (NSAIDs) may interfere with hemostasis during the perioperative period, and the combination of NSAID and enoxaparin could increase this effect. The aim of this prospective, blinded experimental study was to assess these effects using a model of arterial thrombosis and bleeding in the rabbit.
Methods: After anesthesia was induced and monitors placed, the common carotid arteries were exposed, and 60% stenosis of the right common carotid artery was produced. Twenty minutes later, a compression injury of the artery was produced that triggered a series of cyclic episodes of thrombosis and clot lysis. This was manifested as cyclic flow reductions (CFR; measured with an electromagnetic flow meter). After the first flow reduction was noted, the rabbits were immediately and randomly assigned to one of four groups (n = 10 each) that received intravenous infusions: control, ketorolac (2 mg/kg), enoxaparin (0.5 mg/kg), and ketorolac plus enoxaparin (2 mg/kg and 0.5 mg/kg, respectively). The number of CFRs that occurred in the subsequent 20-min period was used as a measure of treatment effect. The contralateral common carotid artery was exposed, and both stenosis and injury were produced. The ability of the administered drug to prevent thrombosis was assessed as the number of CFRs that occurred during the first 20-min period after vessel injury. In addition, both before and after group assignment and drug injection, bleeding times were noted and a platelet aggregation test was performed. Laparotomy was followed by a spleen section, and the extent of the wound and the amount of splenic bleeding were measured.
Results: The treatment effect was indicated by the median number of CFRs, which was 5.5 in the control group, 1 in the ketorolac group, 2 in the enoxaparin group, and 0 in the ketorolac + enoxaparin group. The prevention effect was indicated by the median number of CFRs, which was 4 in the control group, 0 in the ketorolac group, 2 in the enoxaparin group, and 0.5 in the ketorolac + enoxaparin group. Bleeding time was significantly lengthened in the enoxaparin and in the ketorolac + enoxaparin groups. Splenic and wound bleeding was greater in the ketorolac group. Platelet aggregation was completely inhibited in the ketorolac and the ketorolac + enoxaparin groups. 相似文献
In reaction time (RT) tasks, event-related potentials (ERPs) reveal a response-locked negative wave when subjects commit errors. This wave, termed "error negativity" (Ne) or "error-related negativity" (ERN), is thought to index response-monitoring processes. With conventional monopolar recordings, this negativity is hardly seen on correct responses, likely overlapped by a large positive wave. Indeed, after Laplacian transformation (a spatial high-pass filter), a small Ne-like wave is unmasked. Recently, it has been shown that the positivity on monopolar recordings was larger for correct responses preceding an error than for correct responses preceding a correct trial. After Laplacian transformation, it appears that this effect is due, at least in part, to a decrease of the Ne-like wave on correct responses preceding an error. This result indicates that, as the Ne on errors, the Ne-like wave on correct responses is sensitive to performance and hence is likely related to response-monitoring processes. 相似文献